It can cause damage or air leakage. 100 8 7 to 9 150 1/8 14 12 to 14 200 1/4 17 22 to 24 200 3/8 21 28 to 30 200 1/2 24 Lock Nut Tightening Torque Caution 1. Suitable screw torque for a hexagon lock nut is shown in the table below. For standard installation, turn 15 to 30 using tool, after fastening by hand. Pay attention not to over torque the product.

For example, when using 2 auto drains, 1.5 kW (200 l/min (ANR)) of the compressor capacity is required. Operating pressure: 0.1 MPa or more. Operating pressure for AD17/27: 0.1 MPa or more. Operating pressure for AD37/47: 0.15 MPa or more. 2.

DC Specification Temperature increase (C) Note) Power consumption (W) (Holding) 24 VDC 0.19 0.29 0.44 Inrush current (A) (Inrush time: 200 ms) Model 12 VDC 0.38 0.58 0.88 25 25 30 1.5 2.3 3 VXE21 VXE22 VXE23 Note) Value for ambient temperature at 20C and when the rated voltage is applied.

S L, Z S L, Z 1 1 1 1 4 1 2 PB AC 2 Ordering example (Example) Series VXR22, Rc 1 1/4, 200 VAC, Conduit terminal (Part no.)

Ordering example (Example) Series VXP22, 32A Flange, 200 VAC, DIN terminal (Part no.) VXP2272-32-2D Made to Order Specifications Splashproof Specifications ( ) Based on JIS C 0920 Based on IEC529IP-X4 VXP Model Port size Electrical entry X36 DIN terminal or class H coil not available. 17-3-47 The VX series will be revised shortly.

160 200 50 100 150 200 0 0 0 Load (N) Load (N) Load (N) D-X Individual -X 139 Series MXF Construction !

to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz)Three phase 170 to 253 VACSingle phase 170 to 253 VAC1.5Single phase 200 to 230 VAC (50/60 Hz)Single phase 170 to 253 VAC0.210 inputs6 outputs1 M (when differential receiver), 200 k (when open collector)0 to ?

958 219 78 100 11.0 463 916 485 170 IDF90 Anchor bolt location Hole diameter:13 Unit: mm IDF80 IDF90 IDF60 745 (957) (Air dryer outside) (Air dryer outside) 704 916 (Air dryer outside) 330 355 (Air dryer outside) (485) 463 IDF70 890 (Air dryer outside) 849 (Air dryer outside) 365 390 IDF60/70/80/90 Series 7.3 Dimensions 7-3 IDX-OM-V022 Chapter 7 Documents 7.4 Electric circuit IDF60/70 200

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.

Tubing for AD27-D: I.D. 2.5 (3/32") or larger, Length 5 m (200 inch) or shorter Tubing for AD37, 47(N)-D: I.D. 4 (3/16") or larger, Length 5 m (200 inch) or shorter Tubing for AD38, 48(N)-D: I.D. 6.5 (1/4") or larger, Length 5 m (200 inch) or shorter 8) Pipework for auto drain discharge which rises higher than the auto drain outlet should be avoided.

Selects the time to hold the input signal. 15 ms 200 ms Memorizes the number of times the input device is ON. Generates error per channel when the operation count exceeds the set value. 3 Enable Generates an error.

Piston seal NBR Valve seal Non-lube Tube gasket CS1N125A-PS 125 140 160 180 200 CS1N125A-PS CS1N140A-PS CS1N160A-PS CS1N180A-PS CS1N200A-PS CS1N140A-PS Piston gasket Component part numbers: @8, #0, #1, #2, #3, #5.

Reed switch Solid state switch 5 V IC circuit Z76 Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Y es Relay, PLC 24 V 2-wire 100 V, 200 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V 100 V, 200 V 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication

, 250, 300, 350, 400, 450, 500 Replacement Parts: Seal Kits 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 50, 63 Bore size (mm) Contents Kit No. 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 80, 100 40 50 63 80 100 CA2Y40-PS Rod seal 1 pc.

JIS symbol Minimum Operating Pressure Unit: MPa Bore size (mm) Minimum operating pressure 20 25 32 40 50 63 80 100 0.02 0.01 Standard Stroke Table Replacement Parts: Seal Kits Bore size (mm) Bore size (mm) 20 25, 32, 40, 50, 63, 80, 100 Standard stroke (mm) Note 1) Contents Kit No. 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 20 25 32 40 50 63 80 100 CG1Y20-PS CG1Y25

300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400 500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Piston speed mm/s Features 6

or less 0.02/200 or less 0.02/200 or less 0.02/200 or less Simplified Selection Flow Chart Simplified Selection Flow Chart Simplified Selection Flow Chart Single Axis Electric Actuator Series LTF (AC Servomotor) Single Axis Electric Actuator Series LTF (AC Servomotor) Work load kg Maximum speed mm/s Positioning repeatability mm Guide type Motor type Lead screw Series Capacity Brake Ground

For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500