Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: None, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Membrane air dryer series, Mist separator or micro mist separator combined w/single unit, Compatible with a wide range of flow rates, Compact, lightweight, space saving, AIR DRYER, M'BRANE W/SEPARATOR, MEMBRANE AIR DRYER
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Metric sizes Inch sizes Model Port size 1/8 12 10 8 5/16 3/8 6 1/4 5/32 3/16 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32UNF NPT1/8 NPT1/4 NPT1/4 NPT3/8 NPT1/2 Specifications Proof pressure JIS symbol 1.5MPa (218psi) 1MPa (145psi) 0.1MPa (14.5psi
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, N59, 51 lb
36 21 33.9 43.2 18.5 13.2 10 1/4" 40.4 35.4 34.4 29.4 18.5 34 18.5 AS321FG-02-06 AS221FG-N02-09 27.2 36.4 60 17 27.8 39.3 12.8 15.2 6 5/16" 20 21 36 AS321FG-02-08 AS221FG-N02-11 33.9 43.2 63 18.5 29.5 41 15.2 17.9 8 3/8" 23 43.8 48.8 21.8 19 42.8 37.8 R 1/4 AS321FG-02-10 AS321FG-N02-07 27.8 39.3 67 21 31.8 43.3 18.5 13.2 10 1/4" 17 60 NPT 1/4 AS321FG-02-12 AS321FG-N02-09 19 21.8 29.5 41
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8), Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3