Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Filtration efficiency 99.9% Membrane FGH200 to 300 0.2 m EB ES X40 0.4 m Port size Element classification Note) 03 04 06 10 Rc3/8 Rc1/2 Rc3/4 Rc1 Element HEPO 2 Membrane Symbol J D Note) Refer to pages 70 to 73 for details about specifications, models, dimensions, etc. regarding the elements.
Model Description AMR3000 AMR4000 AMR5000 AMR6000 : E4-02 : E4-03 : E4-04 1 4 3 8 1 2 1 4 1 2 : E6-06 : E6-10 3 4 1 : E3-02 : E3-03 : E5-04 : E5-06 Adapter assembly (6) 3 8 3 4 AD33-X203 AD33-X202 AD33-X210 AD33-X201 Float style auto drain (Bowl assembly) IS1000-01 (Set at 0.4MPa) Compact pressure switch PT elbow (7) 135510 135613 Note 5) in the gauge part number (e.g.
1 q t i 16-11-40 5 Series PF2D Digital Flow Switch For Deionized Water and Chemicals Dimensions: Separate Type Sensor Unit PF2D504-11/520-13 Internal circuit and wiring example 60 70 176 z to , are terminal numbers.
A [mm] Weight [g] 01 50 mm IBG1-12-10-50 57 35 02 100 mm IBG1-12-10-100 107 40 03 150 mm IBG1-12-10-150 157 45 04 300 mm IBG1-12-10-300 307 59 11 Long nozzle with a silencer Long nozzle 50 mm IBG1-12-10-50S 72 57 12 100 mm IBG1-12-10-100S 122 62 13 150 mm IBG1-12-10-150S 172 67 14 300 mm IBG1-12-10-300S 322 81 Long nozzle Long nozzle with a silencer IBG10_11/With fitting Symbol Type Applicable
DIN terminal 3 8 3 8 DO DIN terminal (Without connector) 04 1 2 1 2 1 2 3 4 1 2 3 4 1 04 5 06 Body ported G Grommet (Lead wire length 300 mm) 10 1 1 1 H Grommet (Lead wire length 600 mm) 10 7 12 14 9 20 2 E Grommet terminal 1 4 1 T Conduit terminal 1 4 1 2 D DIN terminal 1 2 G Grommet (Lead wire length 300 mm) Grommet (Lead wire length 600 mm) DIN terminal DIN terminal (Without connector)
L1 D L2 L3 L4 L5 L6 L8 Model Port size AS2000E-01 4.5 16 57 61.5 15.5 10 17 30 5 40 1/8 AS2000E-02 4.5 20 59 63.5 17 12 23 30 5 40 1/4 AS3000E-02, 03 5.5 26 69 76 20.6 13.25 25 45.5 5.25 56 1/4, 3/8 AS4000E 2-1/4 to 1/2 72 (Max. 80) Effective thread depth 6 15-9-42
10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.
5 to 40 Circulating fluid flow setting range*4 L/min 10 to 40 10 to 40 Circulating fluid discharge pressure display range MPa 0 to 1.5 0 to 1.5 -30 to 40C: Galden HT135*5 FluorinertTM FC-3283*5 20 to 90C: Galden HT200*5 FluorinertTM FC-40*5 Circulating fluid (No intrusion of foreign body) Refrigerant R404A (HFC) R404A (HFC) Quantity of refrigerant kg 2.9 0.72 (At 20L/min) 0.72 (At 20L/min
Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.
Mode button 1s Set button 1s or Mode button 1s Set button 1s B D C Fig. 40 No.DIG-31900-OM002 49 B Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-1 C Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 40-2 D Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant
D X IDK02-100 IDK02-200 IDK04-100 IDK04-200 IDK06-100 IDK06-200 100 200 100 200 100 200 120 220 140 240 140 240 2 x 1.2 D 4 x 2.5 Inner sleeve 6 x 4 Note) Dimensions at 40% relative humidity. Dimensions may change if the relative humidity changes.
D-sub Connector. Series SV D-sub Connector. How to Order . Manifold Electrical Wiring. Dimensions . Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV1000 for D-sub Connector. Series SV2000 for D-sub Connector. Series SV3000 for D-sub Connector. Series SV4000 for D-sub Connector. Flat Ribbon Cable Connector . Series SV Flat Ribbon Cable Connector.
No.IP8S-OM09 52 Set button 1s or Select linearity Mode button 1s or Select equal percentage 1:25 or Select equal percentage 1:50 or Select quick opening 1:25 or Select quick opening 1:50 or User Mode button Set button 1s 1s or Set button Mode button 1s 1s D E Fig. 40-1 No.IP8S-OM09 53 or Set button Set button 1s 1s 0% position setting (%) D Mode button Mode button 1s 1s or 10% position
H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port