SMC Corporation of America
Elite Part Number Search
Search Results "HRSH100-W-20"

(Initial value) Solenoid Specifications Note 3) The weight W is the value for the manifold only. To obtain the weight with solenoid valves, add the solenoid valve weights for the required number of stations. Refer to the separate catalog ES11-75B regarding DIN rail weight.

0 o i Integral ttings/LQ1 w e Component Parts No. Description Material Note 1 Body PFA 2 Housing PVDF 3 Diaphragm FKM 4 Plate PVDF 5 Diaphragm PTFE 6 Housing PVDF 7 Diaphragm PTFE 8 Guide PPS 9 End plate PVDF 10 Spring Stainless steel Fluorine coated 11 Nut PFA 12 Insert bushing PFA r t y !2 !1 o i u !0 q Tube extensions w e Component Parts No.

Necessary condition is that TEMP PV value after 60sec. is 20+/-2.0C or less. See 5.3.4 Status screen 3on page 5-4 for the details of display position.

less 250 x 250 18 625 or less 282 Body size under 100 to 150 350 or less 300 x 300 20 900 or less 339 20 to 350 under 150 to 200 400 or less 23 Over 900 under 200 to 250 450 or less Order a thickness equal to or greater than that shown on the table.

Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 12 10 8 6 4 3.2 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M50.8 6, 10, 16, 20 AS231FG-01 AS221FG-01 20, 25, 32 R 1/8 AS231FG-02 AS221FG-02 20, 25, 32, 40 R 1/4 AS331FG-02 AS321FG-02 40, 50, 63 R 1/4 AS331FG-03 AS321FG-03 40, 50, 63 R 3/8 AS431FG-04 AS421FG-04 63, 80, 100 R 1/2

Brow n Pow er suppl y N ot e) The w i re col or i s f or w hen opt i onal cabl e i s used.

O ut put area I nput area W o rd d ata area In p u t w o rd d ata Rem arks W o rd d ata area O u tp u t w o rd d ata Rem arks RW w 0 b15, b14, b1, b0 b 1 1b 0100% F.S. RW r0 b15, b14, b1, b0 b 1 1b 0100% F.S. RW w 1 U nused RW r1 U nused RW w 2 U nused RW r2 U nused RW w 3 U nused RW r3 U nused O ut put dat a occupi es 4 w ords, but uses onl y t he 1st w ord act ual l y.

Unit conversion function W Window comparator mode An output type that holds the output when the pressure is within a certain range. (Refer to "List of output mode" on page 20.) Durability to voltage applied between an electric circuit and a body. A product's durability in withstanding voltage. If more voltage is applied to the product, the product may be broken.

mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W704 0.5 4 PF3W720 2 16 PF3W740 5 40 PF3W711 10 100 PF3W721 30 250 -79No.PF-OMM0004-D / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -80No.PF-OMM0004-D PF3W704/720/740/711 A AA B D E F G H J K L N P PF3W704 3/8 70 50 30 60 40.6 15.2 24 14 35 26 18 13.6 2.7 14 PF3W720

40 11 21 0.5~4 L/min 2~16 L/min 5~40 L/min 10~100 L/min 50~250 L/min 2 04 20 40 11 21 R 04 20 40 11 21 S 250L/min G L/min(gal/min) / : SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] 1=9/5+32 L/min 100L/min250L/min Rc N NPT F G IS0228 1 N M8(3m) 04 20 40 11 21 03 3/8 04 1/2 06 3/4 10 1/1 12 11/4 14 11/2 / OUT1 OUT2 1 1~5 V 2 4~20 mA 1T 1~5 V 1~5 V (PF3W3)1~5V (-1-1T) 4

: 201 to 300mm 80 40 50 50 20 20 Load weight m (kg) Load weight m (kg) Load weight m (kg) 20 10 10 10 63 63 63 5 5 5 50 50 50 [Example ] 40 40 40 1 1 1 70 100 300 500 1000 70 100 300 500 1000 70 100 300 500 1000 Stroke (mm) Stroke (mm) Stroke (mm) 2.

20 0 0 0 20 40 40 80 60 120 80 160 100 200 120 240 140 280 160 320 180 360 200 400 Current (mA) 24 VDC 12 VDC Note 1) Follow the same procedure for selecting PVQ10 series. 2) Flow rate depends on individual differences between valves and piping conditions.

If it must be used under such conditions due to unavoidable circumstances, contact SMC beforehand. w Do not use it with anything other than dry air (such as air containing moisture).

AL-OMX0056-A PRODUCT NAME Lubricator MODEL / Series / Product Number AL20-(F,N)01(F,N)02(B)(-2,3,6,C,R,Z)-D AL30-(F,N)02(F,N)03(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)02(F,N)04(B)(-2,3,6,8,R,W,Z)-D AL40-(F,N)06(B)(-2,3,6,8,R,W,Z)-D AL50-(F,N)06(F,N)10(B)(-2,3,6,8,R,W,Z)-D AL60-(F,N)10(B)(-2,3,6,8,R,W,Z)-D Contents Page 1. Safety Instructions 2-6 2. Application 7 3. Standard Specifications 7 4.

Output type Number of outputs 2 points Internal power supply method Integrated power supply method (Power block: supplied from EX9-PE1) Power supply method Output specification Output device supply voltage 24 VDC Max. 42 mA/point (1.0 W/point) Note) Max. 0.5 A/point (12 W/point) Output device supply current Display Yellow LED (Lights when power is turned ON.)

Indicator light (AC) When solenoid gets energized, indicator light illuminates, thus electrical states of the solenoid can be seen from the outside. 51 VA (64 VA ) 50 Hz Inrush Apparent power (VA) (Power consumption (W)) 45 VA (55 VA ) 60 Hz AC 17 VA (5.3/5.5 W) 50 Hz Holding 11 VA (2.9/3.2 W) 60 Hz 5.5 DC Power consumption (W) In the case of 3 position type.

Drip failure can cause damage to the components that need lubrication. 0.04 0.02 0 0 2000 4000 6000 8000 Flow rate L/min (ANR) 51 Lubricator AL10 to 60 Construction AL10 AL20 w w e q q t IN OUT IN OUT y y r u u AL30, 40 AL50, 60 w w q t q e e t IN OUT OUT IN y r i r u y u Parts list Description Material Note No.

LED level meter Easy-to-operate large dial Above set position Set position Below set position Red Green Green Extraneous material W W W Scale provides guidelines for set position. 2 wiring methods Centralized Wiring Individual wiring Minimum operating pressure 30 kPa (ISA2-G) Energy consumption can be reduced compared with the conventional models (Conventional models: 50 kPa) Position of

Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 10 (10 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.