SMC Corporation of America
Elite Part Number Search
Search Results "VZM550-N01-34R"

Nozzle Diameter: ø0.7mm, Vacuum Pressure: -90 kPa, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer

Nozzle Diameter: ø0.5mm, Vacuum Pressure: -48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A, SUP: Screw-in NPT 1/8, VAC: Screw-in NPT 1/8, EXH: Screw-in NPT 1/8, Accessories: w/o Bracket, w/o Silencer

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.15 to 0.9MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency

The VM series is a mechanical, poppet valve. Their compact size requires little mounting space. The VM series offers a wide variety of actuator styles and flow capacity up to 1.0 Cv.Fluid: air, Operating pressure: -100kPa to 1.0MPa, Effective area (Cv): 7mm 2 (0.38), Ambient and fluid temperature: -5 to 60C (no freezing), Port size (nominal size): 1/8 (6A), European threads-G(PF), VALVE

This is a legacy product, and replaced byVM230-02-34RA, VALVE, MECHL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, 0.41576 lb

Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.15 to 0.9MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE SOL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, F7, VM BODY PT 1/4, .39600 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, MECH VALVE, VALVE, VM (VFM/VZM) MECHANICAL VALVE, DA, VM BODY PT 1/8, .37106 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MECHL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, BA, VM BODY PT(M5, NON-US STD), .42932 lb

This is a legacy product, and replaced byVM130-01-34RA, MECH VALVE, VALVE, VM (VFM/VZM) MECHANICAL VALVE, DA, VM BODY PT 1/8, .34716 lb

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: K (Operation Manual, Calibration Certificate)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)