SMC Corporation of America
Elite Part Number Search
Search Results "VV5FS3-10-101-03-C5"

Example) AL30-03B-2R Symbol Description Body size 20 30 40 50 60 10 Metric thread (M5) Rc NPT G Nil Thread type N F + M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 Port size + Nil B Note 1) Option (Mounting) Without mounting option With bracket + Polycarbonate bowl 1000 cm3 tank 1000 cm3 tank (with switch) Lowest limit ON 1000 cm3 tank (with switch) Lowest limit OFF Metal bowl Nylon bowl

Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.

(Except 10.) For other lengths, consult SMC.

motor 8 12 8 12 24 5 10 5 10 Vertical 32 10 12 10 20 10 12 10 20 40 High rigidity direct acting guide LJ1H 20 20 40 44 Horizontal 50 25 25 60 Non-standard motor 8 12 8 12 66 5 10 5 10 Vertical 74 10 10 82 Options Page 100 Made to Order 101 Clean room specification 104 Dust seal specification 110 TSUBAKI CABLEVEYOR specification 122 Construction 134 Mounting 140 Non-standard

Y = L2 = X = L1 = (mm) (mm) L2 6 (9 Y) to Y 7 (10 Y) to Y Y 3 to 9 3 to 10 L1 {10 (18 X) } to (X 2) {10 (20 X) } to (X 2) X 8 to18 10 to 20 Size 10 15 Size 10 15 Symbol: A11 Symbol: A12 Symbol: A13 Shaft with through-hole Minimum machining diameter for d1 is 0.1.

14 4 4 6 10 14 4 4 6 10 14 6 10 16 20 25 6 10 16 20 25 6 10 16 20 25 Double acting Single acting type, Normally closed Normally closed Normally open MHZ MHF Single acting 3.7 12 31 56 83 MHL Refer to pages 436 to 440 for the specifications with auto switch.

REAL40 REAL25 REAL32 Model 10 (2.48 1.3 x 10-3 x ST) 30 10 (1.98 1.3 x 10-3 x ST) 10 (2.26 1.3 x 10-3 x ST) = 50 20 2.

14 22 30 4 4 6 10 14 22 30 4 4 6 10 14 22 30 6 10 16 20 25 32 40 6 10 16 20 25 32 40 6 10 16 20 25 32 40 32, 40 Double acting Normally closed Normally open Single acting 3.7 13 38 57 83 161 267 JIS Symbol Double acting Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.

14 22 30 4 4 6 10 14 22 30 4 4 6 10 14 22 30 6 10 16 20 25 32 40 6 10 16 20 25 32 40 6 10 16 20 25 32 40 32, 40 Double acting Normally closed Normally open Single acting 3.7 13 38 57 83 161 267 JIS Symbol Double acting Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.

10.5 20 9.5 6 10 35.5 72 19 17.5 CY1R10 9 38 3.5 4 M3 x 0.5 4.5 M5 x 0.8 68 14 14 20 13 8 15 39.5 76 26 17.5 CY1R50 25 110 8.6 10 M8 x 1.25 15 Rc 1/4 159 48 42 60 41 10 50 113 176 82 30 CY1R63 24 118 8.6 10 M8 x 1.25 16 Rc 1/4 171 60 48 70 47 10 60 121 188 94 32 8-15-42 42 Series CY1R Magnetically Coupled Rodless Cylinder Direct Mount Type Centralized Piping Type: 10, 50, 63 CY1RG Bore size

Applicable shaft types: S, W d1 = d1 = E3 = E1 = L2 = Y = L4 = L3 = Size 10, 15 Size 20, 30, 40 L1 = X = (mm) d1 Size 10 15 20 30 40 E4 = E2 = 2 to 3 2 to 4 2.5 to 3.5 3 to 5.5 4 to 7 (mm) (mm) L4 max Y Y L2 6 (9 Y) to Y 7 (10 Y) to Y Y 3 to 9 3 to10 L3 max X 2 X 2 L1 {10 (18 X)} to (X 2) {10 (20 X)} to (X 2) X 8 to 18 10 to 20 Size 10 15 Size 10 15 Symbol: A14 Symbol: A15 Symbol

Single Axis Electric Actuator Series LJ1H High Rigidity Direct Acting Guide Lead screw lead mm Mounting Series Motor type Guide type Page Model orientation Ground ball screw Rolled ball screw 12 10 20 12 10 20 LJ1H10 LJ1H20 LJ1H30 LJ1H10 LJ1H20 LJ1H30 Page 2 to Horizontal Page 6 to High rigidity direct acting guide 25 25 Page 14 to Standard LJ1H motor 8 12 8 12 Page 18 to 5 10 5 10 Vertical

Electric Actuator with Integrated Guide Series LTF Series LTF Lead screw lead mm Page Series Guide type Motor type Model Mounting orientation Ground ball screw Rolled ball screw 6 10 20 10 20 6 10 20 10 20 LTF6 LTF8 LTF6 LTF8 Page 60 to Horizontal 10 10 Page 68 to Standard Frame-type LTF motor linear guide 6 6 Page 76 to Vertical 10 10 Page 84 to Construction Page 92 Mounting Page 93

CRQ2X MSQX MRQ Size: 10 to 200 B A Magnet Operating range at proper mounting position (Lm/2) Most sensitive position Operating range of single auto switch Lm Reed auto switch Solid state auto switch D-M9(V), D-M9W(V) D-A9, D-A9V Size Rotation Hysteresis angle Hysteresis angle Operating angle m 10 10 10 10 10 10 10 Operating angle m 10 10 10 10 10 10 10 A B A B 90 80 65 50 45 40 35 55 45

ASN How to Order AQ ASN2 03 ASV JIS Symbol AK Option Nil S None With seal ASS Port size ASR M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASF Thread type Metric thread (M5) Unified thread (10-32 UNF) R NPT Nil N Needle Valve/Flow Characteristics Inlet pressure: 0.5 MPa Flow rate (l/min (ANR)) Effective area (mm2) Number of needle rotations 15-11-1 Series ASN Construction Component

VFA5120-03 2 pcs. VFA5220-03 2 pcs. DXT156-19-1A 1 pc.

, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MXQ6-20 MXQ6-20 0.010 0.02 MXQ6-20 MXQ6-20 MXQ6-40 MXQ6-40 0.03 MXQ6-40 MXQ6-40 0.02 MXQ6-10 MXQ6-10 0.01 0.005 MXQ6-10 MXQ6-10 0.01 0 0 40 80 120 10 20 30 10 20 30 0 Load (N) Load (N) Load (N) 8 8 8 Lr = 70 mm MXQ8-75 MXQ8-75 MXQ8-75 MXQ8-10 MXQ8-10 MXQ8-20 MXQ8-20 MXQ8-30 MXQ8-30 MXQ8

10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40, 50 2 x 4, 3.5 x 7, 4 x 10 10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40 to 50 4, 6 Nylon tube, 4, 6 Urethane tube Vacuum entry Thread dia.