Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5.
Do not operate by fixing the table and moving the actuator body. 16. The belt drive actuator cannot be used vertically for applications. 114
Do not use compressed air that contains chemicals, organic solvents, salt, or corrosive gases. Failure to discharge the condensate will allow the accumulated condensate to flow over to the outlet side. Do not use compressed gas containing chemicals, organic solvents, salt, or corrosive gas. This can cause rust, damage to rubber and resin parts, or malfunction. 4.
Do not exceed specified current or the LED might be damaged and not function. 3. The indicator light is lit when switch is off for D-P70 4. Do not drop, dent, or allow excessive impact to cylinder during handling. 5. Keep at least 20mm away from each other when 2 or more cylinders with high magnetic field resistance auto switch are mounted in parallel. and D-P75.
Do not separate the cylinder from the valve. 2. Do not disassemble or modify the guide rod. 3. This product should not be used as a stopper. Cushion Rubber bumper Stroke length tolerance dose not include the amount of bumper change.
Do not apply negative pressure. It may result in malfunction. Should they remain, they could cause malfunction. 3. When connecting pipes and fittings, etc., be sure 3. Do not supply air pressure from ports other than that neither chips from the pipe threads nor sealing material get inside the valve.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Do not use standard dew point 40C (symbol L) type, standard dew point 60C (symbol S) type and IDG30, 50, 30H, 50H for dehumidifying breathing air. Do not use only outlet air (dried air) in a closed room. Caution 1. Devise a layout which considers the position of purge air discharge ports. Purge air is humid air.
Do not operate the cylinder in such a way that an external force causes the workpiece to move while being clamped (Fig. (6)). 6. Furthermore, do not operate the cylinder in an application in which a rotational force will be applied to the piston rod. RE A B REC CX 1. Do not operate the cylinder horizontally. CY 2. Do not perform any work in the rotary direction.
In the case of auto switch rail mounting style, do not remove the rail that is mounted.
Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.
Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Reset applied pressure to a level within the set pressure range.
Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bracket mounting Mount the bracket using the mounting screws supplied. The required tightening torque is 0.420.04 Nm.
The unit specification is displayed approx. 1 second Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Nominal thread size Required torque Rc (NPT)1/8 7 to 9 Nm System error. The internal circuit may be damaged. Do not use the product for flammable fluid. A fire or explosion can result. Only dry air, N2, CO2 and Ar are applicable.
Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product for flammable fluid. A fire or explosion can result. Only air and N2 are applicable. Do not use the product in a place where static electricity is a problem.
Function selection mode Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. seconds, to display [F 0]. Select to display the function to be changed [F].
P_2 P_1 Instantaneous flow Set value or 3 4 Set value or 3 Excessive instantaneous flow Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Hysteresis 1 Hysteresis 1 L Flow has exceeded the upper limit of the display flow range. Reduce the flow.