Do not use in atmospheres where the valve is in direct contact with corrosive gases, chemicals, salt water, water or steam. 2. Do not use in an explosive atmosphere. 3. Do not use in locations subject to vibration or impact. Confirm the specifications in the main section of the catalog. 4. Use a protective cover, etc., to shield valves from direct sunlight. 5.

(Do not change.) Pin 3 Reserved. (Do not change.) OFF Pin 4 Reserved. (Do not change.) OFF When using the MECHATROLINK-III standard servo profile, set the number of transmission bytes to either 32 or 48. When using the MECHATROLINK-II-compatible profile, set the number of transmission bytes to either 16 or 32.

Nylon tube Within 0.1mm Soft nylon tube Within 0.1mm Polyurethane tube Within+0.15mm, Within -0.2mm Do not use tube which do not meet these outside diameter tolerances.

If the maximum air flow rate is momentarily exceeded, it may cause splashing of drainage and oil on the outlet side, and damage to the equipment. -5- Installation Warning (1) Do not drop or apply impact during transportation or installation. It will cause damage to the product and result in operation failure. (2) Do not install in areas of high humidity or high temperature.

If the maximum air flow rate is momentarily exceeded, it may cause splashing of drainage and oil on the outlet side, and damage to the equipment. -5- Installation Warning (1) Do not drop or apply impact during transportation or installation. It will cause damage to the product and result in operation failure. (2) Do not install in areas of high humidity or high temperature.

No output Reduction of the set pressure Unstable set pressure Delay in increase of the downstream pressure Operating environment Warning (1) Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. (2) Do not operate in a location subject to vibration or impact.

No output Reduction of the set pressure Unstable set pressure Delay in increase of the downstream pressure Operating environment Warning (1) Do not use in an environment where corrosive gases, chemicals, sea water, water or steam are present. (2) Do not operate in a location subject to vibration or impact.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system.

Supply rated pressure. (100 kPa to 200 kPa) Supply pressure error Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.

Do not use tool for mounting because the bowl may be damaged. Refer to the Check item for referential tightening torque. Referential tightening torque: 1.5 Nm Disassembly 1) Remove the bowl assembly. Hold the bowl assembly by hand and rotate counterclockwise to remove the bowl assembly.

In incorporating the element to the element guide, do not drop the element from the upper end of the element guide. Actuators Modular F.R.L.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Regulator and filter regulator 1) Be sure to unlock the handle before adjusting the pressure and to lock it after the pressure is set. 2) During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 3) Do not install it iin an area that is exposed to high temperature or humidity, because doing so will lead to improper operation

Do not use them if pressure or temperature exceed specifications, since this may cause damage and/or malfunctions. (Refer to the specifications.) 1.

Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. Please contact SMC when using a fluid other than compressed air. We do not guarantee against any damage if the product is used outside of the specification range. 2.

Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not use in a place subject to heavy vibration and/or shock. 3. Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion.

Do not use in locations having an explosive atmosphere. 2. Do not operate in locations where vibration or impact occurs. 3. In locations near heat sources, block off radiation heat. 4. Do not use in environments which exceed the ambient temperature specifications of the product. Caution 1.

Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.

Operating pressure Do not use the product beyond the operating pressure range. Do not use in locations where peak pressure exceeds the operating pressure due to water hammer, surge pressure, etc. FGC Bag filter FGF FGF Fluid release valve Tank FGH 2. Operating temperature Do not use the product beyond the operating temperature range.