(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.
bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt With adjustment bolt Configuration Shock absorber model MY1 W MY1 W 0 to 6 6 to 12 12 to 18 0 to 11.5 11.5 to 23 23 to 34.5 0 to 12 12 to 24 24 to 36 0 to 16 16 to 32 32 to 48 0 to 20 20 to 40 40 to 60 0 to 25 25 to 50 50 to 75 0 to 5.6 5.6 to 11.2 11.2 to 16.8 Without spacer Stroke adjustment range
Dimensions/20 to 40 Basic/CM2YB Width across flats B2 2-P (Port size) (Rc, NPT, G) 2-NN H1 H2 G G Width across flats B1 I 2-Eh8 D MM AL A F F NA 1.5 1.5 N N K H S + Stroke ZZ + Stroke Boss-cut ZZ + Stroke (mm) A AL B1 B2 D E F G H H1 H2 I K MM N NA NN P S ZZ Bore size (mm) 20 25 32 40 0 0.033 0 0.033 0 0.033 0 0.039 18 15.5 13 26 8 13 8 41 5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 62 116 20
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Process Pump Built-in Solenoid Valve Type/Air Operated Type Performance Curves/Built-in Solenoid Type/Air Operated Type 1l/min = 0.035SCFM 1MPa = 145psi Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 16 Series PB1000 Performance Curves/Built-in Solenoid Type/Air Operated Type Cycle 1Hz Cycle 5Hz Cycle 10Hz 70 70 70 60 60 60 50 50 50 40 40 40 Total lifting range m Total lifting range m Total lifting range m SUP=0.7MPa SUP=0.7MPa SUP=0.7MPa SUP=0.5MPa SUP=0.5MPa SUP=0.5MPa
IZF21/31 IZF10/IZF10R Technical Data With automatic cleaning unit IZF21-m-mmSm IZF31-m-mmSm 64 (144) 20.5 (40) 64 (40) (104) 20.5 153 113.4 (195) (155) With adjustable louver IZF21-m-mmWm IZF31-m-mmWm (60) (144) 14 (40) 127 (60) (104) 14 (40) 89 127 89 (195) (155) With filter IZF21-m-mmmU IZF31-m-mmmU (144) (45) 134 5 (40) (45) (104) 5 (40) 95.5 126 87 (195) (155) 18 IZF21/31 Series Dimensions
(chattering) Keep the actuator 40 mm or more away from adjacent actuators to avoid the influence of magnetic fields.
48 56 58.5 41 50 60 68 64 76 86 91 18 24 30 35 28 34 40 40 11.5 14 15 17.5 15 17 20 20 20.5 25 30 34 12.8 19 23 23 M4 M5 M5 M5 VCA21 VCA31 1/4 1/4, 3/8 3/8, 1/2 3/4 VCA41 4 Series VCA How to Order Manifolds (VCA20) VV2C A 2 02 02 How to Order Manifold Assemblies (Example) Enter the valve and option models to be mounted under the manifold base part number.
60 40 40 40 40 27 27 27 40 27 Suction flow rate Suction flow rate Suction flow rate Suction flow rate 20 13 13 13 13 20 0 60 40 20 0.6 0.3 0.5 0.4 0.2 0 0.1 0 60 40 20 0 0.6 0.5 0.4 0.3 0.2 0.1 Supply pressure (MPa) Flow rate (l/min (ANR)) Supply pressure (MPa) Flow rate (l/min (ANR)) 13-4-26 7 Series ZM Vacuum Ejector: With Solid State Timer Exhaust Characteristics/Flow Characteristics,
MPa) Fluid: Water LVR20 LVR40 LVR50 12 [45] 26 [100] 1.1 [4] 24 [90] 11 [40] 0.9 [3.5] Flow rate gal/min [L/min] Flow rate gal/min [L/min] Flow rate gal/min [L/min] 21 [80] 9.2 [35] 0.8 [3] 18 [70] 7.9 [30] 0.7 [2.5] 16 [60] 6.6 [25] 13 [50] 0.5 [2] 5.3 [20] 11 [40] 0.4 [1.5] 4.0 [15] 8 [30] 0.3 [1] 2.6 [10] 5 [20] 0.1 [0.5] 1.3 [5] 2.6 [10] 0 0 0 0 0 0 15 [0.1] 29 [0.2] 44 [0.3] 58 [0.4
How to Order EX9-FU EX510-DX EX510-DY3 EX510-DY4 10 Applicable model Rated current Rated insulation capacity Fuse resistance value 1 A 5 A Fuse rated current 48 VAC/DC 50 A 0.145 18 m 10 50 1 A 5 A 1721 Series EX510 Ordering Examples Shown is an example for ordering the EX510 series.
2 18 18.5 AR20-A 1/8, 1/4 1/8 40 67.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 43.9 5.4 15.4 55 2.3 27.3 36.5 17.5 6 AR25-A 1/4, 3/8 1/8 53 70.4 23.5 22 M36 x 1.5 22 37.5 58.5 37.5 59.5 30 34 44.3 5.4 15.4 55 2.3 30.3 36.5 17.5 6 AR30-A 1/4, 3/8 1/8 53 83.5 27 28.5 M45 x 1.5 28.5 37.5 65 37.5 66 41 36 46 6.5 24 65 2.3 32.5 45.5 22.5 7 AR40-A 1/4, 3/8, 1/2 1/8 70 100 33.5 34.5 M52
D-Z73 D-Y59B D-Y59A Load voltage 24 VDC,100 VAC 24 VDC (10 to 28 VDC) 28 VDC or less Load current range Indicator light Application Relay, PLC 24 VDC Relay, PLC IC circuit, Relay, PLC 5 to 40 mA, 5 to 20 mA 5 to 40 mA 40 mA or less PLC: Programmable Logic Controller Refer to page 889 for the applicable auto switch list.
60% 40% 92% 8% 1.050.0 L/min 1.052.5 L/min 052.5 L/min 5.00 V 20.0 mA 90% 10% PFM750 80% 20% 1.040.0 L/min 1.042.0 L/min 042 L/min 4.20 V 16.8 mA 70% 30% 60% 40% 92% 8% 2100 L/min 2105 L/min 0105 L/min 5.00 V 20.0 mA 90% 10% PFM711 80% 20% 290 L/min 295 L/min 095 L/min 4.60 V 18.4 mA 70% 30% 280 L/min 284 L/min 084 L/min 4.20 V 16.8 mA 60% 40% 420 mA 15V [mA] [V] -76No.PF-OMJ0005CN-I Revision
Excessive accumulated flow 5% of maximum rated flow [00.05] 00.05 gal/min (4 L type) [00.21] 00.21 gal/min (16 L type) [000.5] 000.5 gal/min (40 L type) [001.3] 001.3 gal/min (100 L type) [000.3] 000.3 gal/min (250 L type) Temperature upper limit exceeded The fluid temperature is above 110 oC. Reduce the fluid temperature.
HECR008-W HECR012-W 1 Unused BUS + 0 0 Operation temp. range 10.0 to 60.0 C (No dew condensation) 5 4 3 2 1 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 During operation or maintenance of the product, do not disable the Communication Indication temp. range -9.9 to 80.0 C 2 RXD (RD) Unused Circulating fluid temp. deg.C Circulating fluid temp. deg.C connector Temp: 10 to 35 C Humidity : 35
Table 1 Tightening torque (Unit: Nm) Foot Flange Clevis Trunnion B CG1*20 1.5 1.5 to 2.2 CG1*25 2.9 2.5 to 3.5 CG1*32 2.9 6.0 to 8.6 CG1*40 4.9 10.8 to 14.6 CG1*50 11.8 19 to 25 CG1*63 24.5 30 to 40 CG1*80 24.5 --CG1*100 42.2 --8)Do not hit or grasp the sliding parts of the cylinder tube and piston rod with other objects.
bore size (mm) Name of CAD file Page in Vol.3 Series/Variation Standard Copperfree 6 10 12 16 20 25 32 40 50 63 80 100 125 Parallel style gripper Series MHZ Standard MHZ2 2.1-1 2.1-18 With dust cover MHZJ2 Angular style gripper Series MHC SMH03 2.6-1 MHC2 Standard Toggle style air gripper Series MHT SMHT2 2.7-1 20-MHT2 Standard Parallel style gripper Series MHS MHS2 2.5-3 SMHS1 2 finger
350 0.7 DC DC VXF 2160 5 to 60 580 VC 1.0 AC AC 10 to 60 VXF2160 VXFA2160 1.0 0.03 330 2.0 1 27 VXFA 2160 5 to 40 400 0.7 DC DC VDW Solenoid type VXF 2280 5 to 60 1.0 1500 AC AC VXF2280 VXFA2280 VQ 10 to 60 1.0 0.03 810 2.0 40 1 2 1 VXFA 2280 5 to 40 0.7 1300 DC DC VX2 Note 1) Dew point shall be 10C or less.
40 VDW Air consumption 100 l/min (ANR) Air consumption 200 l/min (ANR) 30 30 Air consumption 100 l/min (ANR) Air consumption 50 l/min (ANR) VQ 20 SUP = 0.2 MPa 20 SUP = 0.2 MPa VX2 10 10 VX 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find the pilot air pressure and