Remarks Weight Lead wire and M12 connector LFE-1-A3 Lead wire length: 3 m Approx. 175 g LFE-1-D Tapping screw 3 x 10, 4 pcs. Approx. 45 g Bracket LFE-2-D Tapping screw 3 x 10, 4 pcs. Approx. 70 g LFE-3-D Tapping screw 3 x 10, 4 pcs.
Rail mounting Direct mounting D-F7BA D-F7lW D-F7lF D-J79W D-A7lH/A80H D-A73C/A80C D-F7l/J79 D-F7lV/J79C D-F9BA D-F9lW D-F9lWV D-F7lWV D-A9l D-A9lV D-F9l D-F9lV D-A79W D-A7l/A80 Bore size (mm) D 8 10.5 13.5 16.5 C 11 15 13 15.5 D 9 11.5 14.5 17.5 C 12 16 14 16.5 D 5 7.5 10.5 13.5 C 8 12 10 12.5 B 7 9.5 12.5 15.5 A 10 14 12 14.5 B 10.5 13 16 19 A 13.5 17.5 15.5 18 B 3.5 6 9 12 A 6.5 10.5 8.5
A Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height [mm] D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV A B 12 (10 x 2) 10.0 2.5 16 (12 x 2) 10.0 2.5 20 (16 x 2) 9.5 6.0 25 (20 x 2) 9.5 6.5 32 (25 x 2) 9.5 8.5 40 (32 x 2) 8.5 16.5 50 (40 x 2) 8.5 23.0 63 (45 x 2) 8.5 27.5 80 (56 x 2) 8.5 41.5 100 (71 x 2) 7.5 46.5 Auto switch model Auto switch model D-M9V D-M9WV D-M9AV Bore size
On B side SY3000-37-80A-7 On A side 1 to 8stations SY3000-37-80A-3 On B side SY3000-37-80A-10 On A side 9 to 12stations SY3000-37-80A-6 On B side SS5YJ7-21,41SA SY3000-37-80A-12 On A side 13to16stations SY3000-37-80A-9 On B side Note 1) The above is for station addition or maintenance.
The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2", "H_2".
8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8,433: *2) 1. 2. 3. 1. 2. 3. 4
d d e d e e d : Cat. 3 can only be achieved with a redundant sensor (2 series NO contacts) and a connecting cable that meets the fault exclusion requirement of EN13849-2. : The category that can be achieved depends on the sensor used. 18 No.EX##-OMY0004 3.3.8.
D -With Built in Magnet (Not available as std. on single acting models, XB6 & XB7) I XBg -Low Friction I XCO -Stainless Steel Rod LNumber of Auto-swircnes -2 pcs. S 1 p c . n n p c s . L Long leads uountng B Front Nose Mount C -Rear Pivot E -Double End K -Non-Rotating Rod R -Block Mount W-Double Rod Auto.Switch 853. D-853 Gsg D-G59 B54. D-854 K59 D-K59 864 .
O R T T H R E A D Nil PT* Remove (N) when ordering T NPTF T Y P E 1 Body Ported 3 Manifold Type Common SUP 5 Manifold Type Individual SUP Vacuum SERIES NZM VACUUM EJECTOR MANIFOLD D I M E N S I O N S NZM VA C U U M E J E C T O R M A N I F O L D 1 10 Stations Common supply and exhaust M a i n t e n a n c e a n d a d j u s t m e n t i s p o s s i b l e w i t h o u t d i s a s s e m b l y
(mm) 4 6 8 10 12 Effective area (mm2) Nylon Urethane 2.6 2.6 6.8 6.8 16.2 13.1 25.6 20.4 35.4 30.4 Note) Weight (g) A L D M Model d KCJ04-99 KCJ06-99 KCJ08-99 KCJ10-99 KCJ12-99 9 13 20 33 43 Note) D: Max. diameter 33.5 37 42.5 49.4 52.4 49.5 54 61 70.4 74.4 9.8 11.8 14 17 19 18 19 21.5 24 25.5 4 6 8 10 12 Applicable fitting Bulkhead Union: KCE H (width across flats) Effective area (mm 2)
Note 2) Fixed unit: kPa ZY Vacuum pressure sensor ZF None Vacuum port adaptor Rc 1/8 Vacuum pressure gauge Digital pressure switch for vacuum Nil GN G D With digital vacuum pressure switch ZP Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) SP N P A B C D E F NPN open collector 1 output PNP open collector 1 output
A B C D E 19.5 20.5 8.5 9.5 1.8 3 6.5 8.5 7 8 2.1 5.5 7.1 7.7 M-01H-4 M-01H-6 90 Miniature Fittings M3, R(PT) 1/8, M5 Series M Series M5 Barb fitting for nylon tube: M-5AN-4, -6 Weight (g) 1.6 1.7 Effective orifice(mm2 Part No. A B C ) 2.1 4.0 12 14 5 8 1.8 2.5 M-5AN-4 M-5AN-6 Barb fitting for soft tube: M-5AU-3, -4, -6 Part No.
Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYV15 CYV32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m: Load mass [kg] L: Distance to load center of gravity [mm] A, B: Distance to guide shaft [mm] g: Gravitational acceleration [9.8m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Central axis of guide Central axis
Weight (g) d L4 Model L3 T D1 H D2 D3 L1 L2 Max. Min.
In periodical inspections, check the following items and replace the parts if necessary. a) Scratches, gouges, abrasion, corrosion b) Air leakage c) Twisting, crushing and turning of connected tubes d) Hardening, deterioration and softening of connected tubes e) Loosening of the nozzle 2.
Configuration 1 master : 1 thermo-chiller 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-17 Connection of RS-232C HRSH Series 3.3Installation 3-25 HRX-OM-R026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4