I nput si gnal O ut put pressure of E/P regul at or O N O FF Sw i t ch out put 10 Key l ocki ng f unct i on CAU TI O N The keys are l ocked af t er t urni ng t he pow er on and can not be operat ed.
I nput si gnal O ut put pressure of E/P regul at or O N O FF Sw i t ch out put 10 Key l ocki ng f unct i on CAU TI O N The keys are l ocked af t er t urni ng t he pow er on and can not be operat ed.
P IP65 equivalent (Dust-tight/Water-jet-proof)/ With vent hole tap Nil Ends tapped/ Body bottom tapped 2 V V When using the dust-tight/water-jet-proof (lP65 equivalent), correctly mount the fitting and tubing to the vent hole tap, and then place the end of the tubing in an area not exposed to dust or water. The fitting and tubing should be provided separately by user.
Power consumption P: 20 [kW] Q = P = 20 [kW] Cooling capacity = Considering a safety factor of 20%, 20 [kW] x 1.2 = V: Power supply voltage P 24 [kW] Power consumption e Derive the heat generation amount from the output. Output (shaft power, etc.) W: 13 [kW] w Derive the heat generation amount from the power supply output.
Power consumption P: 1000 [W] Q = P = 1000 [W] Cooling capacity = Considering a safety factor of 20%, 1000 [W] x 1.2 = 1200 [W] V: Power supply voltage HRSH 090 P HRSH Power consumption HRSE HRSE e Derive the heat generation amount from the output. Output (shaft power etc.) W: 800 [W] w Derive the heat generation amount from the power supply output.
Accessory (Option) Description Page P. 99 Dust-protecting filter set 88 Series IDFBE Model Selection The corrected air flow capacity, which considers the users operating conditions, is required for selecting the air dryer. Please select using the following procedures.
Stroke Reading Cylinder and Counter CE Series CEP1 CEP1 CE1 CE1 CE2 CEP1/CEU5 Resolution: 0.01 mm (Accuracy 0.02 mm) Output function: RS-232C BCD Output: 5 points (Bank switching: 20 points) 31 points (Binary output) ML2B High Precision Stroke Reading Cylinder CEP1 Series 12, 20 Stroke Reading Cylinder CE1 Series 12, 20, 32, 40 50, 63 Multi-counter CEU5 Series DP.647 P.656 P.667 -X 641 Air
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil Standard P Note 1) Axial piping Note 1) The combination of axial piping and both ends adjusters or retraction end adjusters is not available.
D DDE 202-JU FD BC FA H Q AW (UU) SD BH DF (through) JD AY 2-P BG AX DG Front port (Plugged with a hexagon socket head set screw when side ports are used.) SF AV AU BB (Max. approx.
Note) $1, %4 will not be required for the one without rear plate. 9-4-6 7 Fine Lock Cylinder with Guide Series MLGC Dimensions Basic style: With rear plate MLGCB--R4-F through Counterbore G Back side 4-H 2-O through Rear plate P Head side cylinder port BP Unlocking port Unlocked when pressurized CL CL1 P Rod side cylinder port MLGC W U A' CNG MNB Courtesy of Steven Engineering, Inc.-230
[Please Refer to the Following Pages of the Catalog]· P. 258 Filter Regulator AW10-A to AW40-A· P. 259 Filter Regulator AW20-B to AW60-B· P. 259 Filter Regulator With Backflow Function AW20K-B to AW60K-B· P. 260 Mist Separator Regulator AWM20 to AWM40· P. 260 Micro Mist Separator Regulator AWD20 to AWD40· P. 262 Filter Regulator With Built-in Pressure Gauge AWG20/30/40· P. 263 Filter Regulator
Refer to the table for each pressure specification (page 68) Display/set pressure range Display/min. setting unit Power supply voltage 12 to 24 VDC (10%), ripple max. 10% (p-p) Electric spec. Current consumption 25 mA or less Protection Polarity protection Accuracy Display accuracy 0.5%F.S. Min. display unit (at ambient temperature 25 oC Constant temperature) Repeatability 0.1%F.S.
ML2B32 15N Va 0.25m/s 0.5MPa L1 0.05m L2 0.05m W W 1 L L1 W W W M We M3 V M1 V <> W max=60N( Va P 19) a1= W = 15 =0.25 W max 60 M 2 max=2Nm( Va P 19) a2= M = 0.75 =0.375 M max 2 <> We=1.410VaW=1.4100.2515=52.2N M max=3.5Nm( V=1.4Va) M 3 WeL 1 =52.50.05 1 =0.88Nm 3 3 a3= M 3 = 0.88 =0.25 M 3max 3.5 M max=12Nm( V=1.4Va) M 1 WeL 1 1 =52.50.05 1 =0.88Nm 3 3 a4= M 1 =
How to order (P.6). Attachment Protection cover With protective cover and attachments With protective cover. Without attachments Without protective cover and attachments Accessories Used for mounting this product and duAro flange. Refer to 4-3Mounting to duAro flange (P.15). Hexagon socket head cap Positioning pin (510) 1pc. screw (M510) 2 pcs. 4 - 2.
How to order (P.6). Attachment Protection cover With protective cover and attachments With protective cover Without attachments Without protective cover and attachments Accessories Used for mounting this product and NEXTAGE. Refer to 4-3Mounting to NEXTAGE (P.15). Hexagon socket head Flange 1pc. Positioning pin (610) 1pc. cap screw (M610) 2 pcs.
Output form O: 1SHOT output H: HOLD output C: COMPARE output Reading pre-scale setting Command Block # 0 0 P R [CR] Unit No. Command Check sum code Response Block # 0 0 P R [CR] Unit No. Command Response Status Check sum code data Response data details 1 0 0 0 0 0 1 1 Multiplication Pre-scale value Decimal point position Writing pre-scale setting Command Block # 0 0 P W [CR] Unit No.