, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)], D: D
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 3 (ø1.2), 1st Selection Supply Valve and
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: T (NPTF)
Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors. Fieldbus serial transmission system (EX600), SI unit for input/output , Kit types include DeviceNet?, PROFIBUS-DP, CC-Link, EtherCAT, and EtherNet/IP?
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 04 (Sub-plate 1/2)
Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors.
Size: 40 (1/2), Reverse Flow Function: None, Thread: N (NPT), Port Size: 04 (1/2), Accessory 1: D [Float Style Auto Drain (NO)], Pressure Gauge Angle: G1 (Mounting Angle 0°), Accessory 2: H (w/Set Nut), Option 1: None, Option 2: None, Option 3: Z (Name Plate, Bowl Caution Plate & Gauge w/PSI), B: B
Size: 40 (1/2), Reverse Flow Function: None, Thread: N (NPT), Port Size: 04 (1/2), Accessory 1: D [Float Style Auto Drain (NO)], Pressure Gauge Angle: G1 (Mounting Angle 0°), Accessory 2: None, Option 1: None, Option 2: None, Option 3: Z (Name Plate, Bowl Caution Plate & Gauge w/PSI), B: B
Size: 40 (1/2), Reverse Flow Function: None, Thread: F (G), Port Size: 04 (1/2), Accessory 1: D [Float Style Auto Drain (NO)], Pressure Gauge Angle: G2 (Mounting Angle 90°), Accessory 2: None, Option 1: None, Option 2: None, Option 3: None, B: B