Before piping and screwing in couplings, please make sure that sludge trom pipe threading and sealing materials do not go into the pipe. When seal tape is used, tape winding should be done so that 2 threads are left untaDed on the end.
Please make sure that operating conditions do not cause problems since the use of FEP tubing under chemical environment is unsecured.
Do not service or attempt to remove product and machinery/equipment until safety is confirmed. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.
Do not supply or discharge air suddenly. This will cause the temperature to decrease due to air expansion, and the temperature may exceed the operating temperature limit of the air tank. If flow speed becomes faster, a loud noise may be generated by the friction inside the tube.
2 3 L0 V 4 C/Q (IO-Link)/1(SIO) -17No.PS-OMV0003CN-G NPN 2 DC(+) OUT1 OUT2 DC(-) PNP 2 DC(+) OUT1 OUT2 DC(-) IO-Link L+ C/Q IO-Link DO L-18No.PS-OMV0003CN-G [] 3 0.2 [] / UP DOWN OUT1 OUT1 OUT2 OUT2 [F10]30 () SET 1~3 SET 3~5 SET [] [] [] [3 ] (25 ) (55 ) (23 ) (21 ) 30 () 3 -19No.PS-OMV0003CN-G ON OFF ON P_1 H_1 ON OFF ISE70 ISE71 [P_1] OUT1[MPa] 0.500 0.800 [
.(5%) (0~1MPa 0.001MPa 1/1000) () () F () ripple -14No.PS-OMV0008CN-E ( M46L(2)) 0.760.1 Nm A(ZS-50-A) A M4X6L B(ZS-50-B) B M4X6L -15No.PS-OMV0008CN-E 1.50.1 Nm (ZS-48-A) -16No.PS-OMV0008CN-E -02-N02 8~12 Nm -F02 4~5 Nm 24 () -17No.PS-OMV0008CN-E ()336 336 -18No.PS-OMV0008CN-E FG M12 M12 (Port Class A) 1 DC(+) DC1224 V 2 OUT2 2 3 DC(-) 0 V 4 OUT1 1 IO-Link 1 L+ DC1830 V 2 DO
VQC1000/2000 series valves do not come with mounting screws or gaskets. For VQC4000/5000 series valves, when a valve is ordered individually, it comes with a mounting screw but no gasket. VQC1000/2000 series valves do not require separate mounting screws as there are clamp screws built into the manifold.
VQC4000/5000 series valves do not have common polarity.
② For manifolds with serial transmission kits, whether the valves are positive common or negative common depends on the type of protocol. For VQC1000/2000 series valves, install valves with the same common specification as the common specification of your protocol.
Do not restrict the flow rate by plugging or mounting a speed controller to the exhaust port.
In addition, SY7120 series valves do not come with a gasket because they are the equivalent of existing SY7000 series body ported valves.
The SY7000 series body ported valve gasket assembly part number is “SY7000-GS-1.”
Do not tighten or loosen the release bolts excessively. Also, do not tighten them with a pneumatic or electric screwdriver because it may damage internal parts of the product.
For further details, refer to the excerpts from the MWB series “Specific Product Precautions” below.
However, unlike KS and KX series rotary One-touch fittings, they do not rotate with low friction. Do not use the product in a manner in which the connected tube swings or rotates with respect to the fitting.
PF2D series: Pure water and liquids that do not corrode or permeate Teflon (Refer to the list of applicable fluids in the catalog.)
LFE series: Fluids that do not corrode the materials of wetted parts (Refer to the list of applicable fluids in the catalog.)
However, new VX2 (with a white coil) series valves do not have mounting holes on the bottom surface of the body, so brackets cannot be retrofitted.
If the part number is “VX2□□□□XNB,” a bracket can be retrofitted because it has a mounting hole on the bottom surface of the body.
Note) 1/2 port size VX2 series valves do not have an option with brackets as standard.
Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.
Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6 A
How to Order Do not replace heavy duty scrapers. XC4 Since heavy duty scrapers are press-fit, do not replace the cover only, but rather the entire rod cover assembly. The CM2 series cannot replace either heavy duty scraper or rod seal. (It goes for replacing retainer assembly for the CS1 series.) Replace the CNA2 series with the lock unit.
Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14
N Nil Rc 3 1 0 14 to 60 l/min 20 to 1500 l/min 36 to 2600 l/min NPT Specifications Water/Non corrosive liquid Copper alloy Fluid Stainless steel 304 Liquid, which do not corrode stainless steel 304. Max. pressure 1 MPa 1.75 MPa Water resistance Insulation resistance 100 M (500 DC by megameter) 1500 VAC for one min.
Do not use a screwdriver with a large grip or with a tip that does not fit into the trimmer groove because this could strip the groove.