SMC Corporation of America
Elite Part Number Search
Search Results "LVM11-5C-1-10-Q"

Display resolution Output mode OUT1 OUT2 Hysteresis mode 1/10 of P_1 (n_1) 1/10 of P_2 (n_2) Window comparator mode 1/4 of P1H P1L (n1H n1L) 1/4 of P2H P2L (n2H n2L) Error output 1/7 of rated maximum pressure rated minimum pressure Switch output off -51No.PS-OMW0014-B During an error output or when the switch output setting is OFF, the pressure value meter at the atmospheric pressure

setting GC3P-010AS Pressure gauge cover G36-10-01 G46-10-01 Rc G36-4-01 G46-4-01 1 0.2MPa setting G36-10-N01 G46-10-N01 G36-4-N01 G46-4-N01 1 0.2MPa setting Round type pressure gauge NPT G36-P10-N01-X30 G46-P10-N01-X30 Z Imperial unitMPa, psi 0.2MPa setting 1Z G36-P4-N01-X30 G46-P4-N01-X30 Imperial unitMPa, psi G36-10-01 G46-10-01 G G36-4-01 G46-4-01 1 0.2MPa setting G36-10-01-

setting GC3P-010AS Pressure gauge cover Rc G36-10-01 G46-10-01 G36-4-01 G46-4-01 1 0.2MPa setting G36-10-N01 G46-10-N01 G36-4-N01 G46-4-N01 1 0.2MPa setting Round type pressure gauge NPT G36-P10-N01-X30 G46-P10-N01-X30 Z Imperial unitMPa, psi 0.2MPa setting 1Z G36-P4-N01-X30 G46-P4-N01-X30 Imperial unitMPa, psi G G36-10-01 G46-10-01 G36-4-01 G46-4-01 1 0.2MPa setting Rc G36

(Example) SS3YJA3-41-03-M3 . 1 set SYJA314. 1 set SYJA324. 1 set SYJ300-10-2A . 1 set The asterisk denotes the symbol for assembly.

1 . 4-1 4-2 . 4-1 4-2-1 . 4-1 4-2-2 . 4-1 4-2-3 . 4-2 5 5-1 . 5-1 5-2 . 5-3 1 6 6-1 . 6-1 6-2 GWP . 6-1 6-3 . 6-2 6-4 . 6-3 6-5 . 6-4 7 C 7-1 . 7-1 7-2 . 7-1 8 K 8-1 . 8-1 8-2 . 8-1 9 L 9-1 . 9-1 9-2 . 9-1 9-3 (ADH4000-04) . 9-2 9-4 . 9-2 10 R 10-1 . 10-1 10-2 . 10-1 10-3 . 10-1 10-4 . 10-2 10-5 . 10-2 11 T 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4

0 drE (Selection of display value resolution) Setting of display value resolution 0: Normal resolution 1: Lower resolution (1/10) 0x0456 (1110) 0 R/W Y U8 0x00 (0) Display value around 0 is displayed as 0.

0 drE (Selection of display value resolution) Setting of display value resolution 0: Normal resolution 1: Lower resolution (1/10) 0x0456 (1110) 0 R/W Y U8 0x00 (0) Display value around 0 is displayed as 0.

Rated value kPa Pa mbar psi inchHg mmHg inchH2O mmH2O 1 X576 500 Pa 0.001 (Initial value) 0.01 0.001 0.001 0.01 0.01 0.1 0.001 X577 1 kPa (Initial value) 1 0.01 0.001 0.001 0.01 0.01 0.1 0.01 X578 2 kPa (Initial value) 2 0.1 0.001 0.001 0.1 0.01 1 0.01 X579 5 kPa (Initial value) 0.1 0.001 0.01 0.1 0.1 1 0.01 X580 10 kPa (Initial value) 0.1 0.01 0.01 0.1 0.1 1 -: No units for display -30No.PS-OMX1005

5 MPa 5 0.01 0.1 0.1 1 High pressure 10 MPa 10 0.01 0.1 0.1 1 20 MPa 20 0.01 0.1 0.1 2 25 MPa 25 0.02 0.2 0.2 2 Additional range 1 USEr It varies depending on the minimum unit setting of the additional range.

Model Maximum allowable load mass Average speed Va (mm/s) A2 10 11 12 17 A3 6 10 10 11 A4 21 23 28 34 A5 21 23 28 34 A6 10 11 12 17 A1 6 10 10 11 MXF8 MXF12 MXF16 MXF20 0.6 1 2 4 Note) Note) MXF8 MXF12 MXF16 MXF20 1.0 Note) 16 mm for MXF8-10 only. 0.7 Table (4) Maximum Allowable Moment: Mmax (Nm) 0.5 0.4 Model Stroke (mm) 100 18.27 75 7.96 13.70 50 3.34 5.69 9.14 30 0.98 2.22 3.41 6.66

Output mode Display resolution Hysteresis mode 1/10 of P_1(n_1), P_2(n_2) Window comparator mode 1/4 of P1HP1L(n1Hn1L), P2HP2L(n2Hn2L) Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric pressure Compound pressure: Rated maximum pressure 1/4 of the atmospheric pressure Error output Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric

Display resolution Output mode OUT1 OUT2 Hysteresis mode 1/10 of P_1 (n_1) 1/10 of P_2 (n_2) Window comparator mode 1/4 of P1H P1L (n1H n1L) 1/4 of P2H P2L (n2H n2L) Error output 1/7 of rated maximum pressure rated minimum pressure Switch output off -52No.PS-OMW0005-C During an error output or when the switch output setting is OFF, the pressure value meter at the atmospheric pressure

Structural Drawing and Replacement Parts 10 7. Assembly of Optional Parts 11 8. Operation and Adjustment 12-13 9. Trouble Shooting 14-15 10. How to Replace the Components 16-21 10-1. Diaphragm Assembly Replacement 16 10-2. Valve Guide Assembly and Valve Assembly Replacement 17 10-3. Square Embedded Type Pressure Gauge Replacement 18 10-4.

.: IZ-OMR0035 PRODUCT NAME Ionizer MODEL / Series IZF21/31 Series 1 Doc. No.: IZ-OMR0035 Contents Safety Instructions . 3 1. How to Order. 8 1-1. Ionizer . 8 1-2. Accessories. 8 1-3. Option . 10 2. Procedures to Operation . 10 3. Installation and Wiring . 11 3-1 Installation . 11 3-1-1. Precautions for Installation . 11 3-1-2. Installation of Ionizer . 12 3-2. Wiring . 13 3-2-1.

Output mode Display resolution Hysteresis mode 1/10 of P_1(n_1), P_2(n_2) Window comparator mode 1/4 of P1HP1L(n1Hn1L), P2HP2L(n2Hn2L) Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric pressure Compound pressure: Rated maximum pressure 1/4 of the atmospheric pressure Error output Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric

Output mode Display resolution Hysteresis mode 1/10 of P_1(n_1), P_2(n_2) Window comparator mode 1/4 of P1HP1L(n1Hn1L), P2HP2L(n2Hn2L) Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric pressure Compound pressure: Rated maximum pressure 1/4 of the atmospheric pressure Error output Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric

Bowl Assembly Specifications 10-14 7. Assembly of Optional Parts 15 8. Operation and Adjustment 16-19 8-1. Adjustment of Dripping Amount 16 8-2. Lubrication 17-18 8-3. Oil Discharge from the Product with Drain Cock 19 9. Trouble Shooting 20 10. How to Replace the Components 21-30 10-1. Bowl Assembly Replacement 21-23 10-2. Bumper Retainer Assembly Replacement 24-27 10-3.

Symbol Type Nil Rc F G N NPT Micro mist separator Mist separator Symbol Port size Applicable body size 70D 80D 90D 10 1 V 14 1 1/2 V V V 20 2 V Accessory Part Nos. 1 2 Description Model 70D 80D 90D Bracket AM-BM70D AM-BM90D L * Includes mounting bolts (2 pcs.) Construction: AFF, AM, AMD t q IN OUT w Component Parts No.

Input data Offset Meaning MSB LSB MSB LSB (INT) 15 8 7 0 D4 #D3 #D2 #D1 #C4 #C3 #C2 #C1 #B4 #B3 #B2 #B1 #A4 #A3 #A2 #A1 Slave 8 condition 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 Error code COM_D COM_C COM_B COM_A Port 9 diagnostic/ Error code 0 1 1 1 0 0 0 1 0 0 0 1 0 0 0 1 27 No.EX-OMS0014-A Configuration data map Configuration data Offset MSB LSB MSB LSB (INT) 15 8 7 0 0 QC Web COM_D COM_C COM_B

. 7-5 Chapter 8 Option A . 8-1 8.1 SAFETY INSTRUCTIONS FOR USE . 8-1 8.2 SPECIFICATIONS . 8-1 8.3 AIR PIPING . 8-1 8.4 AIR FLOW CAPACITY . 8-1 8.5 AIR/ REFRIGERANT CIRCUIT . 8-2 Chapter 9 Option C . 9-1 9.1 SPECIFICATIONS . 9-1 9.2 PRECAUTIONS FOR INSTALLATION AND HANDLING . 9-1 Chapter 10 Option L . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 SPECIFICATIONS . 10-1 10.3 MOUNT THE HEAVY