Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: -
11 B 6.5 9 12 15 A 9.5 13.5 11.5 14 B 6 8.5 11.5 14.5 A 9 13 11 13.5 32 40 50 63 2.7-6
M16 x 1.5 100 100 125 125 Pad type Material H Heavy duty N S NBR Silicon rubber U Urethane rubber F Fluoro rubber E EPR 13-11-72 5 Vacuum Pad: Large/Heavy Duty Type Vertical Vacuum Entry without Buffer Series ZPT ZPT H-A14 (Male thread) 40 50 ZPT H-B (Female thread) 40 50 Hexagon width across flats 19 Width across flats 24 Hexagon width across flats 19 28 Width across flats 24 ZX ZR A 6
Series NCJP Dimsaians Notei Includes Mounting Nut. 0.43 No.5-40 UNC 0.56 No.10 32 UNF /6 \1/4") 0 (3!