SMC Corporation of America
Elite Part Number Search
Search Results "AC40C-N04C-V-8Z-D"

-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 -69No.PF-OMN0011CN-C / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -70No.PF-OMN0011CN-C

A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.

Dimensions LLHAStations 4-Mounting hole for W Y K A D L2 L1 N Non-locking type Locking type L3 G 60 (H1) (H2) C SMC SMC SMC SMC V 1/4 1/4 1/4 E 3/8 U 2-P port Pitch = B n-A port (mm) Dimensions (mm) B C D E G H1 H2 K N U V W Y A Station Model LLH2A LLH3A LLH4A 2 3 4 5 Model 46.5 31 65 67 19 10 85.5 87 18 27 19 34 M4 5.5 Symbol L1 L2 L3 L1 L2 L3 L1 L2 L3 47 36.5 94.5 76 27.5 19 125.5 127.5

/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ6. CXSJ10 / CXSJ10 11122122Note 2) D B Note 3) (mm) D-M9 34 (35.5) 3.5 (2) 24 (25.5) 6.5 (8) D-A93 30 (31.5) 25.5 (27) 5 (6.5) Symbol A B C D Note 1) The above mentioned values are indicated as a guide for auto switch mounting positions for stroke end detection.

-063 BA4-080 BA4-080 CM3 * The figure shows the mounting example for the D-M9l(V)/M9lW(V)/ M9lA(V)/A9l(V) types.

Max. 3.5 T N S M U D J Bracket (Option) AR20(K)-B to AR40(K)-06-B 2 x P1 Panel fitting dimensions A (Port size) Y W C B Q V K OUT OUT IN IN Z Plate thickness AR20(K)-B to AR30(K)-B: Max. 3.5 AR40(K)-B : Max. 5 R F P2 S (Pressure gauge port size) Bracket (Option) U M J D T N AR50(K)-B/AR60(K)-B 2 x P1 A (Port size) B Q C K OUT IN R F P2 S (Pressure gauge port size) Bracket (Option) T N J

Designation Description Fieldbus interface connector (BUS IN) EtherNet/IPTM connection PORT 1 (M12 4-pin socket, D-coded) 4 2 SI24 V +24 V for SI unit operation 2 1 SV24 V +24 V for solenoid valve 2 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 4-pin plug, A-coded) 3 1 3 SI0 V 0 V for SI unit operation MS NS L/A1 L/A2 PWR(V) 4 Ground

Designation Description 2 Fieldbus interface connector (BUS IN) EtherCAT connection (M12 4-pole socket, D-coded) 4 5 2 *1: Blinking pattern SV24 V +24 V for solenoid valve 1 Power supply connector Power supply with load voltage for valves and operating voltage for SI unit (M12 5-pole plug, A-coded) 3 2 SV0 V 0 V for solenoid valve 200 ms 200 ms 1 SI24 V +24 V for SI unit operation 3 4 Ground

Mounting hole Mounting hole for connection to the valve manifold 7 4 5 2 SV0 V 0 V for solenoid valve 2 OFF SI unit operating voltage is not supplied. Accessories 3 SI24 V +24 V for SI unit operation Green ON Operating normally. ST Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRSH Series 3.3 Installation 3-27 HRX-OM-Q026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

F.S.=514[V] (1%F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1 k 1 M A/D 5 V A/D 5(V)1(M)/(1(k)+1(M))4.995(V)0.005V ) Ripple -8No.PS-OME0003CN-F 1 (DC+) 2 3 (DC-) 4 (IN15 V) A A PSE200/PSE300 (ZS-28-C) M() 37104-3101-000FL Tyco Electronics() 3-1473562-4 () XN2A-1430 () -9No.PS-OME0003CN-F PSE200 PSE300 15V 1 k () -10No.PS-OME0003CN-F (A/D ) () 20 2030 -11No.PS-OME0003CN-F PSE530 PSE531

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

(In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1. Consult SMC concerning water resistance, flexibility of lead wires, and usage at welding sites, etc. 98

Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.

D type DIN connector with 9.4 mm pitch between terminals is not interchangeable. To distinguish from the D type DIN connector, N is listed at the end of voltage symbol.

06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.

***D-A7l, D-A8l, D-F7l and D-J7l are available as option. 4.3-2 Heavy Duty Stopper Cylinder Series RSH Models Applicable auto switch Construction Action Bore size (mm) Reed switch Solid state switch Rod end configuration Mounting Fixed mounting height D-Y5 D-Y6 D-Y7 Double with spring Single/spring extend Flange 20, 32 50, 63 80 D-Z7 D-Z8 Lever with built-in shock absorber MK/MK2 Specifications

Grommet (G) Rated voltage DIN terminal (D) Part no. symbol Standard: Y, V, W Continuous duty type (E) Standard: Y, V, W Continuous duty type (E) W/o indicator light With indicator light W/o indicator light With indicator light W/o indicator light With indicator light Varistor Varistor Diode Diode Coil Coil Coil Coil S AC Vacuum Spec.