Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: None, Option 3: w/o Operation Manual, Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: w/o Operation Manual, w/o Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: w/o Operation Manual, Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket A, Vertical Mounting, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Bracket B, Horizontal Mounting, Option 3: Operation Manual, Calibration Certificate
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Bracket B, Horizontal Mounting, Option 3: -
The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., N63, ZSE20, "VACUUM SWITCH
(A) 2 L: L style (VQ20 Only ) 1 1 (p) Note) Consult SMC if N.O. is desired. Note) If ordering both options, indicate "LF".
MS-5ALHU-3 MS-5P H/DL L/LL For polyurethane tube 3.18/2 x M5 P.339 KC Extention fitting Solid piece moves fitting up from work piece M5 male x M5 female 4/2.5 x M5 MS-5J MS-5ALHU-4 KK For soft nylon and polyurethane tube P.339 KK130 Nipple Fitting to workpiece and fitting to fitting connection M5 male x M5 male 6/4 x M5 MS-5N MS-5ALHU-6 DM P.338 P.339 KDM Universal nipple Hose nipple Body
H1 Width across flats KA 2 x LD GB MM R0.4 D I 0 E0.05 LH L Width across flats B1 ZZ + Stroke S + Stroke H A AL N Y L LX K F Female thread type X effective depth A1 MM ZZ + Stroke H (mm) LD I H1 H K F E A AL L B1 D Stroke range MM LH LX GA GB KA RA S Y 40 30 27 25 6 19 16 47 8 39 Up to 300 52.4 2 32 22 19.5 18 5.5 17 12 32 6 38 Up to 200 42.4 2 25 22 19.5 14 5.5 17 10 32 6 31 Up to 200 36.4
Flat bracket Dimensions L-bracket Description Part no.
(R)1MPa (P1 + 0.1013) = (1 to 1.89)(P2 + 0.1013) Port 1 (P)0.9MPa Subsonic flow Sonic flow (P1 + 0.1013) 1.89 (P2 + 0.1013) Needle fully open 2 (A) Port 3 (R) 2 (A) Flow rate (L/min (ANR)) Reduced pressure supply Port 1 (P) Pressure Characteristics Needle Characteristics Port 2 (A) 1 (P) Shows the outlet pressure (port 3 (R)) change against the inlet pressure (port 2 (A)) change.