Do NOT make upward piping. qFloat style auto drain (N.O.) 1)Use compressor with capacity more than 3.7kw{400L/min (ANR)}. 2)Set pressure more than 0.1MPa wFloat style auto drain (N.C.) 1)Compressor can be used even if energy is under 3.7kw. 2)Set pressure more than 0.15MPa wFloat style auto drain (N.C.) DO NOT pipe upwards. 1.4-13

Do not touch the lock ring. After removal, the lock ring will return to normal position automatically because of a return spring. eBy pushing tighter, lock portion goes over female side guide portion and snaps into window slot portion. Male side protruding portion snaps into female side groove portion. This performs the function of a detent.

The resulting impact cannot be absorbed easily, the stroke position cannot be maintained, and faulty operation may result. t Lubrication The bearing can be used in an oilless state, but when you are going to oil the bearings, do so by using a ball-cup so that no foreign matter will be mixed.

Do not over tighten the lock nut. 4.7-7 Series ML1 Basic Style Bottom side piping port size Mounting side should be processed according to the dimensions below.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 4-17-4

Make sure that dust and/or other foreign materials do not enter the valve from the unused port (e.g. exhaust port). Also, since there is a breathing port for the armature in the manual override part, do not allow accumulation of dust and/or other foreign materials to block bleed port.

Also, since there is a bleed port for the armature in the manual override, do not allow accumulation of dust and/or other foreign materials to block bleed port. Change of Electrical Entry Angle 1. Series VT317 can change electrical entry angle. (4 positions) 2.

Do not use any sealing agent other than seal tape. Design Warning 1. Please contact SMC when fluids other than air are used. 2. Do not supply air pressure from 2(A) port. The air will leak out from 1(P) port. 3. Since the valve allows a small volume of air leakage, it may not be suitable for holding pressure in a pressure vessel.

You do not need to specify "N" (i.e., without lead wire) for D-A3A, D-A44A, D-G39A, and D-K39A. This is the only standard specification automatically available for these models.

DC () Blue D-F9PW D-Y7PW D-F9P D-Y7P DC (+) Brown DC (+) Brown OUT Black OUT Black DC () Blue DC () Blue Indicator light ON D-F9BW D-Y7BW D-F9B D-Y59B OUT (+) Brown OUT (+) Brown Operating range OFF Red Green Indicator Red Optimum operating position OUT () Blue OUT () Blue Contact Protection Box/CD-P1 1, CD-P12 Internal circuit D-A9, Z7, Z8 The above auto switches do

Contact Protection Box/CD-P11, CD-P12 The D-Z7, D-Z8 and D-A9 type switches do not have built-in contact protection circuits. Use a contact protection box in cases such as with an induction load, when the lead wire is longer than 5m or with 100VAC. 1 Operating load is an induction load. 2 Wiring to the load is 5m or longer.

low speed actuation (no control of cylinder output) Example 2) Low speed with output control Precision restrictors Solenoid valve ITV (Electro-pneumatic regulator) Mist separator (0.01 m or less) (0.3 m or less) Mist separator (0.3 m or less) Air filter (5 m or less) IR (Precision regulator) W Air filter (5 m or less) IR (Precision regulator) W When performing control of cylinder output, do

Do not subject the gauge to impacts, such as dropping, during transportation and mounting. This can cause loss of indication accuracy. 2. Do not use in locations with high temperature and humidity. This can cause malfunction. 3. When screwing the pressure gauge into place, be sure to apply your wrench on the square wrench flats.

SG 12 Note 1) Do not orient diodes incorrectly. The amp will fail if connected incorrectly. Servo ON Note 2) Wiring for a standard cable less than 10m. When the cable length is 10m or longer, four lines each of P5 and LG wires should be connected in parallel.

Make sure that the lead wires do not interfere with the slide table at any stroke range. Lead wire cover Figure 3.

(Mp,My values do not apply to this example.) Mr=W (L3 + C) = 10 (.05 + 0.014) =0.64 [N m] W Mr 2 =Mr/Mr max. =0.64/12 =0.053 Mr: Mr max. value is from at Va=300mm/s L3+C Mey=1/3 We (L2 + B) From V = 1.4 Va We = W V = 4/100 10 1.4 300 = 168 [N] Mey = 1/3 168 (0.5 + 0.037) = 4.9 [N m] 3 = Mey/Mey max. = 4.9 / 14.3 = 0.343 (3) Dynamic moment Examine Mey.

Perform changes of the detection position under the same conditions as step 3. 24 Series RSDG Auto Switch Hysteresis Contact Protection Boxes/CD-P1 1, CD-P12 D-C7/C8, D-C73C/C80C The above auto switches do not have internal contact protection circuits. 1. The operating load is an induction load. 2. The length of wiring to the load is 5m or more. 3.

(Do not adjust more than 2mm, as it will not be possible to obtain smooth acceleration and deceleration.) Do not adjust based on the stopper's movement, as this can cause cylinder damage. Stroke Adjustment Loosen the round head Phillips screws, and remove the top covers and dust covers (4pcs.).

Single action positive operation X View M A Automatic / Manual change-over screw (Built-in bleed restriction) Sensitivity adjusting screw (Adjusts GAIN) Stopper screw (Do not move) (15) Diaphragm valve SUP OUT2 OUT1 X (1) Pilot valve Supply valve A Supply valve B (8) Feedback lever (9) Span adjusting lever (7) Exhaust valve Span adjusting lever shaft EXH. (4) Counter weight Diaphragm For