SMC Corporation of America
Elite Part Number Search
Search Results "NCGDN25-1200-XB7"

Standard Stroke Standard stroke (mm) Bore size (mm) Max. stroke 32 700 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Made to Order Specifications (For details, refer to page 6-17-19.) 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50,

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

Action Double acting single rod Fluid Air Proof pressure 1.5MPa Maximum operating pressure 1.0MPa Minimum operating pressure 0.05MPa Ambient and fluid temperature Without auto switch: 10 to 70C, With auto switch: 10 to 60C Cushion Rubber bumper, Air cushion 50 to 1000mm/s 20 to 63 Piston speed 50 to 700mm/s 80, 100 Thread tolerance JIS class 2 +1.4 0 +1.5 0 +1.4 0 +1.5 0 to 1000 mm, to 1200

Thermo-chiller/ Rack Mount Type HRR Series How to Order Option U Air-cooled Refrigeration HRR A 20 012 (UL Standards) Cooling capacity Option 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None DM With electric conductivity control function, Applicable to DI water piping M Applicable to DI water piping T High-pressure pump mounted

RoHS Thermo-chiller Basic Type HRSE Series How to Order Single-phase 100 VAC HRSE A 018 10 Option Cooling capacity 012 Cooling capacity 1000/1200 W (50/60 Hz) 018 Cooling capacity 1400/1600 W (50/60 Hz) Symbol Option Nil None T High pressure pump mounted Note) Cooling method Note) The cooling capacity will decrease by about 100 W from the value in the catalog.

25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80 1400 C95 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250,

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

700 800 900 1.0 Flow rate (l /min (ANR)) Relief flow rate (l /min (ANR)) Supply pressure P1 (MPa) IR2020-02 IR2020-02 IR2020-02 Supply pressure: 1.0 MPa Back pressure: 1.0 MPa 1.0 0.8 0.204 0.9 Set pressure P2 (MPa) Set pressure (MPa) 0.7 Set pressure (MPa) 0.8 0.6 0.202 0.7 Set point 0.5 0.6 0.200 0.5 0.4 0.4 0.3 0.3 0.198 0.2 0.2 0.1 0.1 0.196 0 200 400 600 800 0 200 400 600 800 1000 1200

/W Output type U8 0 Y 0: 2_P (Normal output) 1: 2_n (Reverse output) Setting of OUT2 output value (Hysteresis mode) 1 R/W Hysteresis set value S16 2000 Y Setting range -200 to 4200 Setting of OUT2 hysteresis (Hysteresis mode) 2 R/W Hysteresis S16 200 Y Setting range 0 to 4400 Setting of OUT2 output value (Lower limit of window comparator mode) 3 R/W Lower limit of window comparator S16 1200

Flow-rate Characteristics Note) Values when the main valve is fully open Male thread nozzle High efficiency nozzle 1L = 0.035 SCFM 1L = 0.035 SCFM 14.5 29.0 43.5 58.0 72.5 87.0 102 116 131 145 psi 14.5 29.0 43.5 58.0 72.5 87.0 102 116 131 145 psi 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 400 VMG1-R02-400:4 KNH-R02-200 VMG1-R02-350:3.5 350 VMG1-R02-300:3 Flow rate [

VEXA-18-2A VEX1-18-1A VEX3-32A VEX5-32A VEX7-32A VEX9-32A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G36-10-01 G46-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer N AN101-01 AN210-02 AN120-M5 14-10-3 Series VY1 Characteristics SignalOutlet Pressure Characteristics (Characteristics of pressure setting) VY1A00 1/1B00 1 1 VY1100 1/1200

(mm) Port size Av x 10-6m2 Cv converted 10 10 15 10 15 20 25 35 40 50 1/4 (8A) 1.9 2.4 4.5 2.4 5.5 9.5 13 23 31 49 46 58 110 58 130 230 310 550 740 1200 VXED2130-02 VXED2130-03 VXED2140-03 VXED2130-04 VXED2140-04 VXED2150-06 VXED2260-10 VXED2270-32 VXED2380-40 VXED2390-50 420 0.5 3/8 (10A) 670 500 670 1150 1650 5400 6800 8400 1.0 0.5 Thread (Nominal size) 0.02 1/2 (15A) 1.5 3/4 (20A) 1 (25A

IN Model/Valve Specifications Connection Max. operating pressure differential (MPa) Flow characteristics Water, Oil Weight (g) Min.operating pressure differential (MPa) Orifice size (mm) Max. system pressure (MPa) Model Thread Water Oil Cv converted Av x 10 -6 (m 2) 1 2 3 4 VXR2150-04 VXR2150-06 VXR2260-10 VXR2270-12 VXR2380-14 VXR2390-20 20 20 25 35 40 50 1250 160 180 290 530 720 1200 6.5

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32 , Belt drive , Applicable stroke range: 300, 500, 600, 700, 800, 900, 1000, 1200, 1500, 1800, 2000 , 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or