Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Fixed SI Unit, Instruction Manual: None, Calibration Certificate: None, Connector: w/o Lead Wire w/Connector, Option: -

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option

Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/4, Piping Entry Direction: Bottom Side, Output Specification: D [1 NPN Outputs + Analog (4 to 20 mA)], Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.  Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

The ISE80 series is a digital pressure switch designed to measure fluids such as tap water, hydraulic fluid, silicon oil, lubricant, fluorocarbon, argon, ammonia, carbon dioxide, air-containing drainage and nitrogen.  Some of the features include 2-color indication, select from back piping and bottom piping, the addition of 2MPa and -101kPa types, also low leakage type, water hammer protection

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)

A96 A96V 5 V IC circuit Yes Reed switch A72 A72H 12 V 200 V 100 V Grommet A93 A90 A93V A90V No IC circuit 5 V,12 V 12 V Relay, PLC 100 V or less 2-wire 24 V A73C A80C A79W Yes No Connector IC circuit 5 V,12 V 24 V or less Yes Grommet With diagnostic output (2-color indication) Solid state auto switches marked with a "" are produced upon receipt of order.

Sensor Type: Contacting, Output Format: PNP Format, Wiring Method: 3-Wire, Type: Main Body, Electrical entry direction: In-line, Lead wire length(m): 0.5, Applicable load: Relay / IC circuit / PLC, Load Voltage: 24 V AC/DC or less, 48 V AC/DC, 100 V AC/DC

Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Electrical entry direction: In-line, Lead wire length(m): 3, Applicable load: Relay / IC circuit / PLC, Load Voltage: 24 V AC/DC or less, 48 V AC/DC, 100 V AC/DC

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 78.00000 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

The ZSE2 series is a compact, pressure switch (for vacuum pressure) and can be integrated with ZX or ZR vacuum systems. The ZSE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, VACUUM SWITCH, ZSE30, ZSE30A, N63, 78 lb

SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.  The series is incredibly compact and lightweight compared to existing flow sensors.  The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon

Indicator light Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Type Special function Electrical entry Wiring (Output) M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V M9NWV M9NW

Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Lead wire length(m): 0.5, Load Voltage: 24 V AC or less / 24 V DC or less

Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Lead wire length(m): None, Load Voltage: 24 V AC or less / 24 V DC or less