For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BYPASS KIT - HRS012-A-20-X047, OTHERS, HRS THERMO-CHILLERS, 27, HRS NO SIZE EUROPEAN

integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BYPASS TO HRS012

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, RIGHT SIDE PANEL HRS012

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, R/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, UPPER PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, LEFT SIDE PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, L/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

Protocol: E (EtherCAT®), Number of Axes, Special Specification: F (1 Axis, w/STO Sub-function), Mounting: 8 (DIN Rail Mounting), Actuator: LEP, Type: S (Table Type), Body Size: 6, Motor Size: Basic, Lead: J (LEP*6: 8; LEP*10: 10), Stroke: 25mm

Special Application: 10-AF (Clean Series), Body Size: 50, Thread: N (NPT), Port Size: 10 [1 (Size 50, 60)], Bracket: B (Bracket, Not Attached), Bowl Type: None, Option: JZ [J+Nameplate/Caution Plate for Bowl in Imperial Units (Size 20 to 60)]

Driver Type: AN (Pulse Input Type, NPN), I/O Cable Length, m: 1 (1.5), Driver Mounting: D (DIN Rail Mounting), Type: S (Miniature Slide Table), Size: 6, Motor Size: Standard, Lead Screw Type: J (Size 6: 8; Size 10: 10), Stroke: 50mm

Driver Type: AP (Pulse Input Type, PNP), I/O Cable Length, m: 1 (1.5), Driver Mounting: D (DIN Rail Mounting), Type: S (Miniature Slide Table), Size: 6, Motor Size: Standard, Lead Screw Type: J (Size 6: 8; Size 10: 10), Stroke: 50mm

Size: 10, Motor Size: Standard, Lead Screw Type, mm: J (LEPS6: 8; LEPS10: 10), Stroke: 25mm, Motor Cable Mounting Direction: Top Entry, Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 1 (1.5), Controller Type - LEC, JXC: 1N (LECP1, Programless Type, NPN)

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.? An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?filter