Cooling method Air cooled 3 RS-232C SD Main functions Offset function, Setting value memory function, Communication, RUN/STOP input signal, Output shut off alarm, Fan speed control Alarm, 5 4 3 2 1 RUN/STOP, 4 RUN/STOP signal Input Input operation and indications RUN/STOP input signal Output shut off alarm Do not modify or reconstruct the unit.

RESET HOLD COM BANK1 BANK2 ) RS-232C AC100 240V COM OUT1 OUT2 OUT3 OUT4 OUT5 S.STOP RD SD SG (+) DC 24V (-) COM COM COM GND 6-2 -A/-COM -B/-COM -B/-COM -A/-COM CEU5 +12V CEU5 3 +12V 1K A 680 COM +12V +12V 680 COM +12 V DC12V,60mA GND F .G . , , 10 - 6-3 (,,) 15mA 10ms COM NPN PNP COM DC24V DC12V PNP ,DC-,NPN ,DC+ CEU5 COM 1 2.2 (DC24V DC12V) 6-4 (,) NPN PNP (OUT15)(S.STOP

P3 Connector type (this product) D-sub9P female connector (M2.60.45) Standard EIA RS-485, RS-232C Protocol Modicon Modbus This system Your system This system Your system 2 Internal 2 Internal SD+ RD circuit circuit 7 3 SDTD Circuit block diagram 5 5 SG SG When RS-232C is selected When RS-485 is selected [Tips] Serial RS-485 and RS-232C must be used separately.

N AC100-240V N L Power supply connector L AC100-240V (IEC60320) E PE E RS-232C RS-485 5 4 3 2 1 1 Unused BUS + Communication 2 RXD (RD) BUS connector 3 TXD (SD) Unused 9 8 7 6 (RS-232C) 4 Unused Unused socket 1pcs D-sub 9 pin (socket type) 5 SG SG Fixed screw: M2.6 6-9 Unused Unused Output Cutoff Alarm a 1 contact (OPEN During Alarm) 2 Output Cutoff Alarm 1 2 3 4 5 Common Output Cutoff Alarm

Otherwise unexpected personnel injury or damage to the product may occur. 3 TXD (SD) Unused Note: Always *Cooling capacity decrease about 50W when high head pump option selected. Ambient environment use shielded 9 8 7 6 HECR012-W 4 Unused Unused cable connected When turning on/off the power observe the procedure. Otherwise 5 SG SG to this connector.

P2 Connector type (this system) D-sub9P female connector Standard EIA RS485 Protocol Modicon Modbus This system Your system Circuit block diagram 2 SD+ 7 Internal SDcircuit 5 SG HRZ Series 8.1 Specification 8-13 HRX-OM-I051 Chapter 8 Appendix 8.1.4 Alarm signal selection User can designate one alarm signal for contact signal.

P2 Connector type (this system) D-sub9P female connector Standard EIA RS485 Protocol Modicon Modbus This system Your system Circuit block diagram 2 SD+ 7 Internal SDcircuit 5 SG HRW Series 8.1 Specification 8-5 HRX-OM-K003 Chapter 8 Appendix 8.1.3 Alarm signal selection User can designate one alarm signal for contact signal. See section 5.3.9 Initial Setting screen for signal selecting.

[ERR19] (AT abnormal) occurs. 3 TXD (SD) Unused Note: Always 3.3.3 Pump Capacity Offset function use shielded 9 8 7 6 4 Unused Unused cable connected This function controls the temperature slide by an offset value from set point temperature.

SET MODE Counter (CEU5) CE2 AC100~240V SD SG RD Relation between Displacement and Output Pulse on Stroke Reading Cylinder External equipment (PLC etc.)