Do not use an application to operate several cylinders simultaneously by adjusting cylinder speed. If this is inevitable, use a high rigid guide against load, so that the cylinder is not damaged even when the each cylinder output is slightly different. 4.
Do not cut the tube with cutting pliers, nippers, scissors, etc.) 2. Grasp the tube, then slowly push it until it comes to a stop. 3. Then, pull it back gently to make sure that it does not come out.
When washing the micromesh element, do not wipe it using a stiff brush or rag. 0.03 12 08 20 24 10 16 Pressure drop (MPa) 06 0.01 0.005 COM. N.O.
When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc.
Do not allow the weight of piping to lie directly on air dryer. 4. Do not connect a tube smaller than the port size to the inlet side. In particular, when using a resin tube, make sure that the size would not be smaller than the port size.
When there are stations which do not require wiring (e.g. individual SUP spacer), specify the wiring specification in the manifold specification so that the number of solenoids is the maximum number of solenoids or less.
Do not operate a cylinder with its bumper bolt removed. If the bumper bolt is removed, the piston hits the head cover, causing damage to the cylinder. Therefore, do not use a cylinder without a bumper bolt. 2. The piston rod must be retracted when mounting the cylinder.
. * If the step motor and servo motors do not meet your specifications, also consider the AC servo specification (Page 46). 38 Model Selection LEF Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Clean Room Specication For the LECPA, refer to page 40.
Do not connect multiple NFC readers / writers to a PC. Connection details of the I/O Configurator for NFC and the wireless unit Before the wireless system can be used, it is necessary to pair each Remote with its Base using the I/O configurator for NFC. The following sections of this document should be read before using the I/O configurator for NFC; 2.
Do not connect multiple NFC readers / writers to a PC. Connection details of the I/O Configurator for NFC and the wireless unit Before the wireless system can be used, it is necessary to pair each slave with its master using the I/O configurator for NFC. The following sections of this document should be read before using the I/O configurator for NFC; 2.
DO (n+1) Output interface Short circuit protection 0 V DO (n) FE / Shield Output circuit / Bus interface 24 V (logic / sensors) 0 V (logic / sensors) 24 V (valves / loads) 0 V (valves / loads) FE BUS . 8-3 EX245-DY1 60 No.EX-OMU0020CN 9.
Do not connect multiple NFC readers / writers to a PC. Connection details of the I/O Configurator for NFC and the wireless unit Before the wireless system can be used, it is necessary to pair each slave with its master using the I/O configurator for NFC. The following sections of this document should be read before using the I/O configurator for NFC; 2.
for mounting attachment) 46 58 45 45 42 26H9 + 0.052 depth1.5 0 30 Positioning pin hole 60 18 5 86 30 107 Auto Switch Mounting Groove Dimensions M5 x 0.8 (Finger opening port) 14 24 M5 x 0.8 (Finger closing port) 42 8 3 4 3 MHY2-25D2 Opening/Closing direction through-hole type 4 x 5.5 through (Hole for mounting attachment) 12 -0.005 -0.025 6 12 22.5 (Limted area for mounting attachment) Do
Do not use the cylinder in the locked state to sustain a load that involves impact. Stopping Accuracy (Not including tolerance of control system.)
When air is supplied to all ports after the solenoid valve is pressure-center positioned, the pistons for rotary operation do not have any thrust, as the pressure in both sides is equal, and the pistons for rotary operation move to the center position due to the thrust of the pistons for center stop.
Do not place your fingers in the clearance between the non-rotating plate and the cylinder tube. Your fingers could get caught between the table and the cylinder tube when the piston rod retracts. If fingers are caught in a cylinder, there is a danger of injury due to the strong cylinder output, and therefore, caution must be exercised. 2.
Note) Do not apply rotational torque to the piston rod. q MK/MK2 RSQ/RSG Connect the shield wire to FG (frame ground).
Do not apply torque directly to the rod. Carbon steel Nickel plated Rod end nut !0 * NBR Rod seal !1 * NBR Piston seal !2 * NBR Tube gasket !3 Note 1) 12: Aluminum bearing alloy. Replacement Parts: Seal Kits Bore size (mm) Kit No. Contents CQSKB12-PS 12 CQSKB16-PS 16 Kits include items !1, !2 and !3 from the table above. CQSKB20-PS 20 CQSKB25-PS 25 *Seal kits consist of items !1, !
Caution Aluminum alloy cast (Steel tubing: Cast iron) Chromated (In case of aluminum alloy cast iron) Non-lube Piston Chromated (In case of aluminum alloy cast iron) Aluminum alloy cast (Steel tubing: Cast iron) Air-hydro Weight/Aluminum tube: Lube style (Non-lube style, Air-hydro style) (kg) Do not open the cushion valve excessively.
Adjust the opening/closing speed of the fingers with a speed controller so that they do not operate any faster than necessary. When fingers open and close faster than necessary, impact on the fingers and other parts increases, causing poor repeatability when gripping workpieces and danger of an adverse effect on the product's life. MRHQ25C P408080-3C 2.