Specification Series LG1H20 Dimensions/LG1H202PA 110 4-M6 x 1 thread depth 10 67 4-M8 x 1.25 thread depth 10 20 8H10 depth 10 LJ1 LG1 LC1 LX LC6D/LC6C Switches Encoder signal line Bending radius 80 Motor power line Bending radius 80 35 8H10 depth 8 85 130 Stroke + 145.7 (table movement range) 77.3 77 107 10 95 Work piece mounting reference plane 55 Body mounting reference plane 52.5 Stroke + 300 1 125

61.9 MXQ25(A) 34.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 25.4 28.7 27.7 27.7 27.7 40.7 40.7 42.7 65.4 65.7 A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6B 18 7.4 7.4 7.4 7.4 7.4 1 11.6 11.6 17.6 34.6 11.6 MXQ8B 29 13.9 13.9 13.9 13.9 13.9 13.9 2 9.1 9.1 17.1 17.1 36.1 36.1 MXQ12B 16.5 16.5 16.5 16.5 16.5 16.5 16.5 16.5 24.1 18.1 18.1 25.1 25.1 31.1 50.1 50.1 MXQ16B 20.6

C A D Model D C Model D C Mounting bolt (mm) Mounting bolt (mm) M18 x 125 l M18 x 135 l 125 135 C (D) Q2WB18010DC C (D) Q2WB20010DC M18 x 135 l M18 x 145 l 135 145 C (D) Q2WB18020DC C (D) Q2WB20020DC M18 x 145 l M18 x 155 l 145 155 C (D) Q2WB18030DC C (D) Q2WB20030DC M18 x 155 l M18 x 165 l 155 165 36 39 C (D) Q2WB18040DC C (D) Q2WB20040DC M18 x 165 l M18 x 175 l 165 175 C (D) Q2WB18050DC

Air Cylinder/Double Rod Type Series CS1W Lube, Non-lube Type: 125, 140, 160, 180 200, 250, 300 Air-hydro Type: 125, 140, 160 Replacement Procedure is P.287 Construction @8 @0 @4 @2 @3@5@1 @6 @7 Lube, non-lube with auto switch Non-lube type With auto switch @2 @3 @3 @3 #1 180, 200 Steel tube 125 to 160 Aluminum tube Air-hydro @8 @0 @4 @2 @3@5 @6 @7 @3 @3 Aluminum tube Auto switch The numbers

Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) note) Foot style, Rod side flange style: 125, 140: 1001 to 1400 stroke, 160: 1201 to 1400 stroke. Air-hydro CS1H125A-PS 125 140 160 CS1H125A-PS CS1H140A-PS CS1H160A-PS Component part numbers: @8, #0, #1, #2, #3, #5. CS1H140A-PS CS1H160A-PS 43

No Initial value Recommended value Number of command input pulses per revolution *3 PA05 0 0 Electronic gear numerator *3 PA06 1 32768 65536 114688 32768 65536 Electronic gear denominator *3 PA07 1 250 125 125 125 250 125 125 Regenerative option PA02 0 0 (Non)/ 0002 (LEC-MR-RB-032)/ 0003 (LEC-MR-RB-12) 1 Rotation direction selection *4 PA14 0 0 (+Counter motors side ) (+Counter motors side

Note 3) Refer to the catalog, since the dimensions of standard stroke Series CQ2 and CQS are different from that of long stroke type. 6-18-1 2 SMC Actuators: Copper-free Air Cylinders 6, 8, 10, 12, 15, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 140, 160 Air Cylinders 20-series has been added by design modification. (98.6.1) Series Application Bore size (mm) Standard Copper-free 6 8 12 (10

Specification Series LG1H20 Dimensions/LG1H202PA 110 4-M6 x 1 thread depth 10 67 4-M8 x 1.25 thread depth 10 20 8H10 depth 10 LJ1 LG1 LC1 LX LC6D/LC6C Switches Encoder signal line Bending radius 80 Motor power line Bending radius 80 35 8H10 depth 8 85 130 Stroke + 145.7 (table movement range) 77.3 77 107 10 95 Work piece mounting reference plane 55 Body mounting reference plane 52.5 Stroke + 300 1 125

Non-standard Motor/Horizontal Mount Specification Series LJ1H10 Dimensions/LJ1H101PB(X10) Scale: 15% 10 6 Work piece mounting reference plane 80 5H10 depth 8 8-M5 x 0.8 thread depth 8 45 20 Cable entry side Body mounting reference plane 5H10 depth 6 Z section detail 100 201 60 50 Z section 43 Stroke + 125 (table movement range) 192 3.3 30 A section 90 83 5.8 1.7 4.8 80 Stroke + 360 A section

Cross sectional area 0.23mm2 3.5 to 7 85.5 78 60 M type plug connctor (M) R 3 1 P (Lead wire length) 82.5 94.5 61.5 300 Cover diameter 1.5 Cross sectional area 0.23mm2 Indicator light R 3 1 P Equation L1=19n+11 L2=19n+23 n: Stations (Max. 20 stations) Dimensions L n 2 49 61 87.5 98 3 68 80 100 110.5 4 87 99 125 135.5 5 106 118 137.5 148 6 125 137 162.5 173 7 144 156 187.5 198 8 163 175 200

(Band) Cylinder series Applicable bore size (mm) 20200 40 180 160 32 140 50 20 25 63 80 100 125 CDV3, CDVS CE2, CNA CDL1 CDS1 Data BD1 -04M BD1 -05M BD1 -06M BD1 -08M BD1 -10M BS1 -125 BS1 -140 BS1 -160 BS1 -180 BS1 -200 BD1 -01M BD1 -02M BD1 -02 BD1 -04M RHC BMB2 -032 BMB2 -040 BMB1 -050 BMB1 -063 BMB1 -080 BMB1 -100 MDB 10-20-71 72 Technical Data 2: How to Mount and Move the Auto Switch

(Including bracket, screw) 40, 50 BA4-040 CDL1, CDNA 63 BA4-063 Applicable bore size (mm) 40 Cylinder series 80, 100 BA4-080 32 50 63 80 100 MDB, MDBB, MDNB CDL1, CDNA 125, 140 BS4-125 Hexagon socket head set screw (M4 x 0.7 x 8 l) Quantity: 2 BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 BAP2-040 BAP2-040 BAP2-063 BAP2-080 BAP2-080 160 BS4-160 CDS1, CDL1, CDLS 180 BS4-180

(Including bracket, screw) 40, 50 BA4-040 CDL1, CDNA 63 BA4-063 Applicable bore size (mm) 40 Cylinder series 80, 100 BA4-080 32 50 63 80 100 MDB, MDBB, MDNB CDL1, CDNA 125, 140 BS4-125 Hexagon socket head set screw (M4 x 0.7 x 8 l) Quantity: 2 BMB3T-040 BMB3T-040 BMB3T-050 BMB3T-050 BMB3T-080 BMB3T-080 BAP2-040 BAP2-040 BAP2-063 BAP2-080 BAP2-080 160 BS4-160 CDS1, CDL1, CDLS 180 BS4-180

Air Cylinder/Standard Type: Lube, Non-lube Type, Air-hydro Type Series CS1 Lube, Non-lube Type: 125, 140, 160, 180 200, 250, 300 Air-hydro Type: 125, 140, 160 Replacement Procedure is P.287 Construction Lube #1 @7 @3 @5#0@8@4 @9 @6 @6 200: More than 998st When the target class 2 pressure vessel #1 @7 @3 @5#0@8@4 @9 @6 Non-lube @6 @6 200: More than 998st When the target class 2 pressure vessel