1 V or less -19No.PS-OMX1005 -C NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less Analog voltage output Output impedance approx. 1 k -D NPN open collector 1 output Max. 28 V, 80 mA Residual voltage 1 V or less Analog current output Max. load impedance 300 at 12 V power supply voltage 600 at 24 V power supply voltage Min. load impedance 50 -E PNP open collector
PFMB7--CNPN (1 output) + Analogue output type (4 to 20 mA) PFMB7--DMaximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Maximum load impedance: 600 NPN (1 output) + External input type PFMB7--GMaximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage
(PNP) 5 V, 12 V IC Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC Grommet 12 V 5 V, 12 V Relay, PLC Diagnostic indication (2-color) 24 V IC 12 V 2-wire Water resistant (2-color) Grommet IC 5 V, 12 V With diagnostic output (2-color) 4-wire (NPN) Latch with diagnostic output (2-color) F7LF 2-wire P5DW Magnetic field resistant (2
Power supply is AC200V single phase (Note 4) Malfunction RA1 OFF ON MC MC SK EMG stop switch Driver Servo amplifier Servo motor MC (Note 7) MCCB CNP1 1-phase 200 V AC to 240 V AC (Note 11) L1 CNP3 (Note 6) U U L2 Motor V V L3 M [1] W NW P3 (Note 1) (Note 10) P4 CNP2 P+ [2] (Note 2) C [3] D (Note 11) (Note 3) Encoder CN2 Encoder L11 cable L21 (Note 8) Main circuit power supply CN3 EM2 24 V
You do not need to specify "N" (i.e., without lead wire) for D-A3, D-A44, D-G39, and D-K39. This is the only standard specification automatically available for these models. D-A9V, M9V, M9WV, and M9A(V) models cannot be mounted on 25 to 40. Since there are applicable auto switches other than listed, refer to page 310 for details.
The power supply for the unit should be 0 V as the standard for both power supply for output as well as power supply for control/input. VQZ SQ VFS +24 V +24 V Power supply for output Power supply for output VFR 0 V 0 V Power supply for control/input +24 V Power supply for control/input 24 V VQ7 4. Do not install a unit in a place where it can be used as a foothold.
AS 0 0.1 0.15 0.2 0.25 0.3 Return stroke pressure (MPa) ASP ASN v v w w a a o o l l v v l l F F e e AQ ASV u u r r e e s s v v s s a a e e l l v v r r P P e e AK ASS ASR ASF Working stroke Working stroke Return stroke Return stroke Pressure valve Flow valve 15-16-1 2 Cuts air consumption by operating the return stroke at a reduced pressure.
Shock absorber specifications cannot be changed by replacing or adding parts. 50 to 500 80 245 80 245 10 to 60 1.96 3.83 15 1.96 4.22 15 Spring force N Extended Compressed Weight g Minimum Strokes for Auto Switch Mounting (mm) Applicable auto switch models Number of auto switches mounted 1 pc. 2 pcs. 5 10 5 10 5 5 D-A9, D-A9V D-F9, D-F9V D-F9W, D-F9WV D-F9BA 2 Series MXP Table Deflection
Symbol Element length Element length L500 (L250 x 2) L750 (L250 x 3) L1000 (L250 x 4) Symbol Element seal material Note 1) B C D Element seal material Non-asbestos Fluororesin NBR FKM A Note 2) T N V Symbol Port size Note 1) Not used with fiber elements.
Symbol Element length Element length L500 (L250 x 2) L750 (L250 x 3) L1000 (L250 x 4) Symbol Element seal material Note 1) B C D Element seal material Non-asbestos Fluororesin NBR FKM A Note 2) T N V Symbol Port size Note 1) Not used with fiber elements.
Write sequentially from the 1st station on the D side.
D-M9/D-A9 Auto switch Figure-16 Auto switch D-M9 D-M9W D-M9AVL model D-M9V D-M9WV D-M9AL D-A9 D-A9V Bore size A B A B A B A B 50 23.5 9.0 23.5 11.0 23.5 7.0 19.5 10.5 (13.0) 63 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 80 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values in brackets are for D-A96.
M9B V V V K59 V V Connector H7C V V V V Solid state auto switch M9NWV M9NW V V V IC circuit G59W V V 3-wire (NPN) 5 V, 12 V Relay, PLC 24 V Yes 3-wire (PNP) M9PWV M9PW V V V G5PW V V Diagnostic indication (2-color indicator) 2-wire 12 V M9BWV M9BW V V V K59W V V Grommet 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 V IC circuit 3-wire (PNP) M9PAV1 M9PA1 V Water resistant (2-color indicator
3-wire (NPN) 5 V, 12 V G39A V IC circuit 2-wire 12 V K39A V Solid state auto switch Relay, PLC Yes 3-wire (NPN) 5 V, 12 V M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW V V V v v 24 V Diagnostic indication (2-color indicator) 3-wire (NPN) 5 V, 12 V M9NAV*1 M9NA*1 v v V v v IC circuit 3-wire (PNP) M9PAV*1 M9PA*1 v v V v v 2-wire 12 V
If 12VDC specifications are required, enter "12" at the end of the assembly part number. 1 2 1 2 P N D side SZ3000-40-6A-D For flat cable 20 pins SZ3000-40-5A-D 1 2 P N 1 2 D side SZ3000-40-8A-D For flat cable 10 pins SZ3000-40-7A-D A connector block assembly can be shipped as an assembly only in the case of double wiring.
Make sure to ground. +24 V +24 V Brown + 24 VDC Brown + 24 VDC +24 V Power supply 24 VDC +24 V Power supply 24 VDC Blue 0 V Blue 0 V 0 V 0 V F.G. F.G. Make sure to ground. Make sure to ground.
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Air filter, regulator and lubricator unit , Clean looking, modular design
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Air filter, regulator and lubricator unit , Clean looking, modular design
SMC's new AC series of modular type F.R.L. unit is available in 4 sizes and is interchangeable with the existing modular type AC line. The element and bowl on the AW and AF series is now one-piece, making element replacement easier. Required maintenance space has been reduced by as much as 46% on the AF series, depending on the body size. Bowls on size 30 or more are now covered with a transparent