10 15 5 3 5 10 15 20 25 30 4.5 10 15 20 30 40 50 60 3 2 6 30 60 8 25 35 10 20 40 10 35 Flow rate Q kg/h Figures inside [ ] indicate the saturated steam holding heat (kcal/kg).
Model Optional specifications AW10(K) AW20P-270AS AR20P-260S AW20(K) AW30(K) AR40P-270AS AR40P-260S AW40(K) AW40(K)-06 AW60(K) AW60P-270AS Note 6) Bracket assembly Note 1) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AR30P-270AS AR30P-260S Note 7) Set nut G36-10-01 G36-2-01 G36-10-01-L G36-2-01-L G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L Round type Note 2) Standard 0.02 to 0.2 MPa
flow range 5 to 500 L/min 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 5 to 525 L/min 10 to 1050 L/min 20 to 2100 L/min Set flow rate range Accumulated flow 0 to 999,999,990 L Instantaneous flow 1 L/min Flow Minimum setting unit Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse Accumulated value hold 1 Every 2 minutes or every 5 minutes
8, R 10, R 10, R 10, R 6 8 10 4 6 KM11 6, 10 One-touch fitting One-touch fitting 1 4 3 8 KM12 6, 10 One-touch fitting Rc KM13 3 One-touch fitting One-touch fitting KM11 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 4 One-touch fitting R male thread KM12 KM14 3 One-touch fitting KM15 KM15 3 One-touch fitting One-touch fitting rod KM16 KM14 KM16 One-touch fitting 3 One-touch fitting KM13 Miniature fittings
Coil rated voltage (V) 24, 6, 12, 48 Allowable voltage fluctuation (%) Power consumption (W) [Current mA] 15 to +10% of rated voltage 1.8 (With indicator light 2.1) [24 VDC: 75 (With indicator light 87.5)] Note) DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Inrush Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200
10 100A CV 50/60Hz 200A CV 50/60Hz 24V DC 12V DC Others (250V or less) E SB Mounting position of silencer box is in accordance with piping of R1 and R2 port. 9 Note) When mixing, inscride a mark and designate a separate piping specification.
MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1 N: Approx. 0. 102 kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100
F F MHL2-10D Z-X85 MHL2-16D Z-X85 1 2 1 2 MHL2-10DZ-X85 MHL2-16DZ-X85 25 25 70 60 70 60 20 20 Pressure 0.6 MPa Gripping force [N] Gripping force [N] Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 50 50 Pressure 0.6 MPa 0.5 MPa 0.5 MPa 15 15 40 40 0.5 MPa 0.5 MPa 0.4 MPa 0.4 MPa 30 30 10 10 0.4 MPa 0.4 MPa 0.30 MPa 0.3 MPa 20 20 5 5 10 10 0 0 10 20 30 40 50 60 70 0
A A F F A F L L L 1 N = 0.2248 lbf 6 6 6 L=80mm L=80mm L=80mm 0.05 0.06 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 0.04 MXPJ6-5 MXPJ6-10 MXPJ6-5 MXPJ6-10 0.05 0.04 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.03 0.04 0.03 0.02 0.03 0.02 0.02 0.01 0.01 0.01 0 10 20 30 40 Load (N) 0 10 20 30 50 Load (N) 0 10 20 30 40 Load (N) 40 10 10 10 L=100mm
/60 Hz 200 VAC 50/60 Hz 100 VAC 50/60 Hz Port size Rc Valve size 1 to 4 1 2 3 Note) N.C.
1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/
ble acting Single rod o12, o16/5to30 o20, o2t5 io 50 o32, @40l5lo 1N o50, 063/10 io 1m Double rod 612, E1U5lo 30 amlo @Q/5to50 o50, 0631 0 to 50 Large bor lize Double acting Single rod101o 300 Double rod 10 to 300 Standard Double acting Single @d o12. a16/5 lo 3A o20 p2t510 50 o32, o40l5 to 1 00 o50 to o10cy10 to 100 Double rod 012, 016/510 30 a20. o25/5 lo 5A 632, 64US lo 1OA o50 lo 0100
C 10 20 30 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-6 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 1000 Cooling capacity W 5 Radiating water flow rate L/min 800 1 3 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
20 25 30 Operating pressure [MPa] Cylinder output F[N] Load weight [kg] 150 15 Allowable side load on the piston end Unit: N 100 10 Stroke of linear part Size 40 40 50 4 5 5 10 15 20 25 30 40 50 75 100 32 40 32 14 14 13 13 13 12 12 11 10 9 20 25 30 2 2.5 3 23 23 22 21 21 20 19 18 16 15 2) Using the cylinder body installed vertically: To operate the rotary cylinder with the cylinder body
(packaged together) 50 80 650 F 40 550 G 10 300 H 4 200 J Filter (IN port) Nil Without filter F With filter Note) 100 Note) Flow reduction rate 50 L/min: 5% or less 100 L/min: 5 to 10% 150 L/min: 10 to 15% 80 600 K 40 500 L 10 250 M 4 150 150 Specifications Flow rate (L/min) [at 0.25 MPa] 50 100 150 Power consumption (W) 80 40 10 4 80 40 10 4 80 40 10 4 Type of actuation 2-position 2 port
Refer to back page 50 for Safety Instructions, pages 543 to 546 for Flow Control Equipment Precautions, and pages 573 to 575 for Specific Product Precautions. Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
B to Nominal filtration accuracy of 5, 10, 25, 50, 100 m can be selected.
L L H Holding point Holding point H MHF2-12D MHF2-8D 80 50 Pressure 0.2MPa 40 60 0.5MPa 0.5MPa Pressure 0.2MPa 0.6MPa 0.6MPa Overhang Hmm Overhang Hmm 0.7MPa 30 0.7MPa 0.3MPa 0.3MPa 40 0.4MPa 0.4MPa 20 20 10 40 20 80 60 40 20 0 0 50 30 10 Gripping point L mm Gripping point L mm MHF2-20D MHF2-16D 100 0.5MPa 100 Pressure 0.2MPa Pressure 0.2MPa 80 0.5MPa 0.6MPa 80 0.6MPa Overhang Hmm Overhang
range 5 to 500 L/mim 10 to 1000 L/mim 20 to 2000 L/mim Instantaneous flow 5 to 525 L/mim 10 to 1050 L/mim 20 to 2100 L/mim Set flow rate range Accumulated flow 0 to 999,999,990 L Instantaneous flow 1 L/min Flow Minimum setting unit Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse Accumulated value hold 2 Every 2 minutes or every 5 minutes Rated
75st Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1N: Approx. 0. 102kgf F Stroke (mm) Bore size (mm) Model 25 50 75 100 125 150 175 200 MGTM 140 151 162 176 193 212 178 204 63