Specifications 10 4. Product outline 10 5. Troubleshooting 11 6. Construction and parts 1112 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
As a guide, insert bolts in 2 locations for 2-5 stations, 3 locations for 6-10 stations, 4 locations for 11-15 stations, and 5 locations for 16-20 stations. 2. When using the manifold with DIN rail in an environment where any vibration or impact is applied to it, the DIN rail itself may be broken.
JIS symbol 2 port valve 3 port valve 10 4. Construction (2) VHK2A(R) VHK3A(R) (9) (4) (1) (5) (3) (11) (10) (7) (8) (6) No.
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 -10 to 50 oC (Max. surrounding air temperature rating: 50 oC) Operating temperature range The status display LED displays the power supply and communication status. -20 to 60 oC Storage temperature range 24 VDC Class2, 2 A Power supply 24 VDC Class2, 2 A Output DeviceNetTM status
8 4 IN 38 27 23 19 11 15 8 MTS 79 68 57 34 45 23 OUT 113 12 6 60 51 43 26 34 17 IN 85 OUT 201 141 121 101 80 60 40 16 8 151 IN 106 91 76 60 45 30 Made to Order Specifications (For details, refer to pages 1955 to 2021.) 220 188 157 126 94 63 OUT 314 20 10 165 142 118 94 71 47 236 IN Note) Theoretical output (N) = Pressure (MPa) x Piston area (mm2) Symbol Specifications -X7 -X9 -X11 -X33 -
Suction cover PVF 1 9 Sound absorbing material B ZL112-SP01 Front cover Without valve PVF 2 10 Sound absorbing material A (set no. for 9, 10 &11) End cover PE 3 11 Suction filter Body 4 When ordering a vacuum pressure gauge or a digital vacuum pressure switch separately, use the part numbers shown in the option specifications on page 3.
Lock keys (refer to P9) Minimum pressure (F_1) adjusting range Maximum pressure (F_2) adjusting range 120% 100% 100% 90% 10% 0% 0% 4 0 0 0 12 10 20mA 20mA 4 0 0 0 12 10 20mA 20mA 2.5 5V 2.5 5V 5 10V 5 10V (Note1) F_1 is adjustable in a range from 0% to 90% of the rated value. (Default value : 0%0.00MPa) (Note2) F_2 is adjustable in a range from 10 to 120% of the rated value.
0 Repair kit for main valve Kit includes parts from 10-1 to 10-5. !0 10-3 !1 G85(B) O-ring Material: NBR Note) When changing parts, follow the instruction manual. Do not disassemble other parts. 10-4 10-5 OUT Precautions Be sure to read before handling.
Bonnet Common IN Individual IN Common IN Individual IN Polyacetal 2 Regulator Regulator ARM2500-A-02 ARM2500-B-02 ARM3000-A-03 ARM3000-B-03 9 1 Replacement Parts End plate R 10 1 Description Material Part no. End plate L 11 1 No.
JM-045 JM-10 JM-10 JM-045 JM-045 *Components include in a seal kit.
Please See Below for How to Order Piston Rod Assembly 7 Rod Bushing Bronze casting Available only as an Assembly Please See Rod/Head Cover NC1A400-10-124 NC1A200-10-124 NC1A250-10-124 NC1A325-10-124 8 Cushion Valve Carbon steel NC1A150-10-124 9 Tie Rod Carbon steel Please See Below for How to Order Tie Rod NCA325-13-Q6311 5008-131 NCA325-31-Q6311 NCA200-13-Q6309 5008-93 NCA250-13-Q6309 5008
Applicable model AR30 AR40 AR40-06 AR50 AR60 Option Note 4) Note 4) Note 1) AR30P-270AS AR40P-270AS AR40P-270AS AR50P-270AS AR50P-270AS Bracket assembly Note 5) Note 5) AR30P-260S AR40P-260S AR40P-260S Set nut G36-10-01 G46-10-02 G46-10-02 G46-10-02 G46-10-02 Round Square embedded type Round Square embedded type 1MPa Note 2) Note 3) Pressure gauge GC3-10AS GC3-10AS GC3-10AS GC3-10AS GC3
(mm) 3.2 4 6 8 10 12 D Tubing I.D.
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
Blow Gun New New RoHS 20 20% reduction reduction 20% reduction with the SMCBlow gun+S coupler+Coil tube in power consumption 10% reduction with theBlow gun (VMG) only New New New With cover Extension nozzle Added 100 mm and 150 mm lengths Pressure loss1% or less M Amount of electricity used in a factory Actuators 10% Air 20% DOWN 20% Air leakage 20% Coolant 30% Air blow 56% Air blow 70% Others
Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.
M1 Weight (g) 4 6 6 8 6 8 10 8 10 8 10 10 12 Applicable tubing O.D. d T H D1 D2 L1 L2 L3 Model AS121-M5-F04 AS121-M5-F06 AS221-01-F06S AS221-01-F08S AS221-02-F06S AS221-02-F08S AS221-02-F10S AS321-02-F08S AS321-02-F10S AS321-03-F08S AS321-03-F10S AS421-04-F10S AS421-04-F12S 16 17 17 18.5 17 18.5 21 18.5 21 18.5 21 21 22 13 13 34 31 54 50 52 86 81 93 88 154 146 21 21.5 25.5 26 M5 x 0.8 28.3
SUP = 0.2 MPa 0.2 0.2 0.1 0.1 0 0 5 0 10 15 20 25 10 0 20 30 40 50 Discharge rate (L/min) Discharge rate (L/min) PAF3413 Air Consumption (4 Hz) PAF5413 Air Consumption (3 Hz) 200 Air consumption (L/min [ANR]) Air consumption (L/min [ANR]) SUP = 0.5 MPa 300 SUP = 0.5 MPa 150 SUP = 0.4 MPa SUP = 0.4 MPa 200 SUP = 0.3 MPa SUP = 0.3 MPa 100 SUP = 0.2 MPa SUP = 0.2 MPa 100 50 0 5 0 0 10 0 10
AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500
Metric size Inch size 3.2 01 03 05 07 09 11 23 04 06 08 10 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Control type 4 6 8 10 0 1 Meter-out Meter-in Use 1/8" tube.