Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling.
Do not scratch or gouge the sliding part of the piston rod or guide rod. This will cause air leakage or malfunction due to damage of the seals. 2.
Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
Do not connect. Do not connect. Connect to actuator power line (Yellow) Connect to actuator power line (Red) Connect to actuator power line (Blue) Connect to actuator power line (Orange) Connect to actuator power line (Black) Connect to actuator power line (White) When an alarm occurs, this signal turns off the alarm after the cause is resolved.
Prevention of electric shock and fire Do not operate the switch with wet hands. Also, do not operate the Thermo-con with water left on it. 2. Action in the case of error If any error such as abnormal sounds, smoke, or bad smell occurs, cut off the power at once, and stop supplying and conveying fluid. Please contact SMC or a sales distributor to repair the Thermo-con. 3.
Do not make any modifications to be product. Do not take the product apart. Piping Caution 1. Before piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping.
Do not use standard dew point 40oC (symbol L) type, standard dew point 60C (symbol S) type and IDG30A, 50A, 30HA, 50HA for dehumidifying breathing air. Do not use only outlet air (dry air) in a closed room. Find the purge air flow rate from the charts and calculate the required outlet air flow rate + purge air flow rate.
Do not use this product with a fluid other than compressed air (e.g. oxygen, hydrogen, inflammable gas, mixed gas, etc.). -Do not use compressed air which includes chemicals, organic solvents, or corrosive gases, etc. It may lead to damage or malfunction. Do not use for caisson shield, breathing, medical purposes, air blow to any medicines and foods that enter the human body.
When a pressure gauge is mounted to the regulator, please do not exceed the maximum display pressure. It may lead to a malfunction.
Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibration and/or shock. 4. Do not mount the product in locations where it is exposed to radiant heat. Warning 3.
Example Warning Mounting 0.1 0.2 0.3 Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. 2. Insert the cable through the conduit and install the wires according to the terminal board layout below. Manifold expansion 0.4 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not use in an environment where flammable gas or explosive gas exists. Usage may cause a fire or explosion. The products do not have an explosion proof construction. Air Supply 1. Type of fluids Please consult with SMC when using the product in applications other than compressed air. 3. Do not use in a place subject to heavy vibration and/or shock. Warning 4.
Do not apply an excessive force to the finger guard. If an excessive external force is applied to the finger guard (including the filter holder) on the air suction side of the product, it may be broken. Do not apply an external force of 50 N or more to the finger guard. Caution 1. Clean specification is not available with this product.
Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 6.
Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water vapor, or where there is direct contact with any of these. 2. Do not use in explosive atmospheres. 3. Do not use in locations subject to vibration or impact. 4. Do not use in locations where radiated heat will be received from nearby heat sources. 5.
Do not use until you can verify that equipment can operate properly. Verify correct mounting by suitable function and leakage inspections after air and power are connected following mounting, maintenance or conversions. 2. Do not drop or bump. Do not drop, bump or apply excessive impact (1000 m/s2) when handling.
Do not operate or set with wet hands. This may lead to an electric shock. End plate bracket (EX600-ZMA2) SUPPLIERS DECLARATION OF CONFORMITY Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Connector (Base only) (2) Add more units.
Do not use with flammable or highly permeable fluids. Fire, explosion, damage or corrosion can result.
Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. 1 L+ Brown 18 to 30 VDC 2 N.C.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.