Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
/4, Non Plug-in Standard 3/4), Thread: F (G)
3/4, Non Plug-in Standard 3/4), Thread: F (G)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Model Type: Standard, Piping: F (Direct Piping Type), Tank Size: None, Port Size: 06 [3/4 (20A)], Thread Type: F (G), OUT Port Piping: None, Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal w/Surge Voltage Suppressor, All Voltages), Fluid and Ambient Temp.: B (-40 to 60°C)
Size: 5 (50), Valve Type: 1 (Normally Closed), Body Material: S (Stainless Steel), Seal Material: F (FKM), Port Size: 06 (Thread; 3/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Size: 5 (50), Body Material: C (Brass), Seal Material: F (FKM), Port Size: 06 (3/4), Thread Type: F (G), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)
Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: F (Switch, -100 to 100 kPa, SI Units only, NPN 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor],
S) D H VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN A port LVC 2-G LVA LVH SMC LVD SMC (J) C LVQ LQ E LVN TI/ TIL PA F K B port E PAX PB A B C D E F G H J K S LVN20 LVN30 LVN40 Model 48 60 72 2.4 7.5 8.0 18 24 30 20 26 33 14 25 25 4 5 6 6 9 11 34.5
How to Order 04 VGA342 A Caution Port size Fluid passage Port thread 1 2 04 Rc(PT) A Normally closed (N.C.) qChange of fluid passage (Standard) Rc(PT) 3 4 06 Rc(PT) B Normally open (N.O.) (Option) 10 Rc(PT)1 F G(PF) N NPT T NPTF Dimensions N.C. N.O. Please note that the pressure in the valve should be exhausted when changing the fluid passage.
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)