Model: 41 (AC), Bar Length: 58 (580mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket
Model: 41 (AC), Bar Length: 34 (340mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: B (w/Bracket 1)
Model: 41 (AC), Bar Length: 34 (340mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller
Model: 41 (AC), Bar Length: 34 (340mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 15 (15m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller
Model: 41 (AC), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 5 (5m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
Model: 41 (AC), Bar Length: 214 (2140mm), Emmiter Cartridge, Material: L (High Energy Saving De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: F (w/Bracket 2), DIN Rail Bracket for Controller
Model: 41 (AC), Bar Length: 64 (640mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1)
Model: 41 (AC), Bar Length: 88 (880mm), Emmiter Cartridge, Material: E (High Speed De-ionizing Cartridge, Silicon), High-voltage Cable Length: 1 (1m), One-touch Fitting: BL (ø3/8" Elbow), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: N (None), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller
Model: 41 (AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 6H (ø6 Straight), Plug Position: w/o Plug, Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
High-voltage Power Supply
Model: 41 (AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
Model: 41 (AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 6H (ø6 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1)
Model: 41 (AC), Bar Length: 16 (160mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 3 (3m), One-touch Fitting: 7H (ø1/4" Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: Nil (40); NPN (41, 42), Power Supply Cable Length: 3 (3m), Bar Bracket: B (w/Bracket 1), DIN Rail Bracket for Controller &
------1/41/8, 1/41/4C37PPSStainless steelNBR FKM EPDMAir, Oil--
Port 2 Port 1 Port 4 Port 3 Port 2 Port 1 Byte 1 Reserved (fixed value: 0) Reserved (fixed value: 0) Input process data Output process data 2 to 129 2 to 39 2 to 65 Process data is assigned to each port based on the process data mapping size setting Process data is assigned to each port based on the process data mapping size setting 40 66 130 Port 1 status (PQI) Reserved (fixed value: 0) 41
EX245-SPN1 GSD . 41 EX245-SPN1 Diagnostics type 1 4 (IN) 1 5.1.1. Diagnostics type 1 Diagnostics type 2 4 (IN) 1 5.2.2. Diagnostics type 2 Valves (16 coils) 2 (OUT) 12 6.3. Valves (32 coils) 4 (OUT) 12 EX245-DX1-X36 2 (IN) 210 7.4. EX245-DY1-X37 1 (OUT) 210 8.4.
F_Par_CRC i-Parameters There are no i-parameters in this product 41 No.EX##-OMY0011-A Appendix C: Checklists The checklists listed in this section provide support when carrying out the following tasks on the SI unit: planning, assembly and electrical installation, commissioning, parameterization, and validation.
In Safety Mode (Channel Passivation) the parameter setting can be either Enable or Disable In Safety Mode (Module Passivation/xxx) the parameter setting is permanently set to Enable 41 No.EX##-OMY0004 8.2.2.5.
SI 1oo1Input N Input N+4 1 1 1oo2Input N Input N+4 11 1oo2 equivalent non-equivalent 1oo2-channel non-equivalentInput N Input N+4 1 39 No.EX##-OMY0006CN 1oo22 2 2 2 SI 40 No.EX##-OMY0006CN Start inhibit after discrepancy Input N Input N+4 Disable Enable 0 Safety Mode (Channel Passivation)Enable , Disable Safety Mode (Module Passivation/xxx)Enable 41 No.EX##-OMY0006CN 8.2.2.5.
Sub display (left) setting Set the sub display (left) from the selection list on page 41. Press the button to set. Move to sub display (right) setting. Return to function selection mode. Sub display (right) setting Set the sub display (right) from the selection list on page 41. Press the button to set. Return to function selection mode.
Setting 21 Default settings 21 F0 Selection of connected sensor Unit selection function 22 F1 Setting of OUT1 24 F2 Setting of OUT2 27 F3 Operating fluid 28 F4 Reference condition 29 F5 Response time 30 F6 Display mode 31 F7 External input 32 F8 Display resolution 35 F9 Auto-preset 36 F10 Accumulated value hold 38 F11 Analogue output filter 39 F12 Power saving mode 40 F13 Security code 41