20 30 40 50 60 Thread type Metric thread (M5) Rc NPT G Nil N F AL20 Port size Body size Symbol Port size M5 1/8 1/4 3/8 1/2 3/4 1 10 20 30 40 50 60 Note 2) M5 01 02 03 04 06 10 Accessory When more than one specification is required, indicate in alphanumeric order.
40 30 20 10 0 1 5 10 50 100 100 90 80 100 90 80 70 60 50 40 30 20 10 0 100 200 300 400 500 100 200 300 400 500 100 200 300 400 500 Elimination ratio (%) Elimination ratio (%) Elimination ratio (%) 75 70 60 50 40 30 20 10 0 1 5 10 50 30 100 1 5 10 50 100 Flow-back count Flow-back count Flow-back count Explanation of graph Explanation of graph Example: Elimination ratio and concentration after
CM PE FM1 PRS P FM2 PE CM FM 12 OLR PTC PTC ILS PRS TB PE GFCI EDV 6 3 6 6 4 2 6 4 7 A A 7 1 7 2 A m 3/h(ANR) 1) (50/60Hz) 0.32/0.375 10 1ANR 65% 2 7 3 7 1 8 C 8 C 8-1 8-2 1) 2) 8-3 8 1 9 G G 9-1 9 1 10 H 10 H 10-1 ( ) 10-2 () AD48-2-A 10 IDFA6E-20-H N.O. () 0.151.0MPa 10 1 10 H IDF-S1941 () 1 AD48-2-A 1 1) 2019 3 2019 2 SERIAL No.XP IDF-S1940
to 350 to 290 to 240 Features 2 Electric Actuator with Integrated Guide Series LTF Lead screw lead mm Mounting orientation Motor type Series Page Model Guide type Ground ball screw Rolled ball screw 6 10 20 10 20 10 20 10 20 6 10 20 10 20 10 20 10 20 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 LTF6 LTF8 P.2 Horizontal 10 10 P.10 Standard motor 6 6 P.18 Vertical 10 10 P.26 Frame-type linear guide LTF
15 to +10% of rated voltage Inrush 12.7 (50), 10.7 (60) 7.6 (50), 5.4 (60) 4.8 W, 5 W (With indicator light) Power consumption Note) N.C.
400, 450, 500 CA2 Up to 1800 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper -XC5 Heat resistant cylinder (10 to 110C) -XC6 Made of stainless steel*3 *4 Up to 2700 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XC7 Tie-rod
Outlet dew point oC 10 Amount of cooling water (50/60Hz) Note 2) L/min 100 Cooling tower capacity Note 3) RT 10 Cooling water pressure drop (50/60Hz) MPa 0.05 (excluding automatic fluid filling valve) Fluid port size 1 1/4 union Power supply voltage (frequency) Note 4) Refer to Table 1 (50/60Hz) Electric characteristic Power consumption (50/60Hz) Note 5) Refer to Table 1 Running current
PF2W504(T) 0.5 4 PF2W520(T) 2 16 PF2W540(T) 5 40 PF2W511 10 100 Measurable range of ethylene glycol aqueous solution (Reference value) : The product with operating fluid temperature specification [0 to 50 oC] is not suitable for fluids with a temperature greater than 50 oC. -24No.PF-OMO0014-D Dimensions (in mm) PF2W504/520 Output specifications A B C Output for PF2W3 48 mm 62 mm 94.3 mm Output
Cylinder specification Bore size (mm) 32 40 50 63 80 100 Action Double acting/single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.08MPa Without auto switch-10 to 70 Ambient and fluid (No freezing) temperatures With auto switch-10 to 60 Lubricant Not required (Non-lube) Piston speed 50 to 1,000mm/s * Stroke length tolerance [mm] Up to 500st+2.0
Cylinder specification Bore size (mm) 32 40 50 63 80 100 Action Double acting/single rod Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.08MPa Without auto switch-10 to 70 Ambient and fluid (No freezing) temperatures With auto switch-10 to 60 Lubricant Not required (Non-lube) Piston speed 50 to 1,000mm/s * Stroke length tolerance [mm] Up to 500st+2.0
Size M Size N Unit number Pilot unit part number Part number Orifice size Stroke 10 to 85mm (Accessory Nil) Actuator Capacity 90cm3 P368010-20 125 150 P565010-18 P36801080 0.7 35 to 100mm (Accessory E) 180cm3 P368010-21 110 195 P565010-19 P36801081 1 50 to 140mm (Accessory F) P368010-22 110 275 Fork lever joints (IP8100 type) Two types of the fork lever joints are available dependent upon
Option R . 10-1 10.1 Safety instructions for use . 10-1 10.2 Specifications . 10-1 10.3 Connection of power supply . 10-2 10.4 Handling Precautions of the Earth Leakage Breaker . 10-2 10.5 Electrical circuit diagram . 10-2 Chapter 11 Inspection record .11-1 11.1 Inspection record . 11-1 IDF190D/240D Series IDX-OM-X011 Chapter 1 Safety Chapter 1 Safety 1.1 Before Using the Air Dryer Before
Model Option 10-/21-AR20(K)-B 10-/21-AR25(K)-B 10-/21-AR30(K)-B 10-/21-AR40(K)-B 10-/21-AR40(K)-06-B 10-/21-AR50(K)-B 10-/21-AR60(K)-B Bracket assembly Note 1) AR50P-270AS Note 2) AR20P-270AS Note 3) Note 3) AR25P-270AS AR30P-270AS AR40P-270AS Set nut AR20P-260S AR25P-260S AR30P-260S AR40P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) 10: G49-4-01, 21: G49-4-01
66 17 10 218 80 22 10 218 80 19 10 241 90 25 10 241 90 21 10 277 100 30 10 334 150 40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37
0 0.043 43 8 50 16 40 13 22 5 2 8 12 1.0 M5 1.1-10
/60 Hz 32 VAC, 50/60 Hz 42 VAC, 50/60 Hz 230 VAC, 50/60 Hz 100 VDC 6 VDC 48 VDC 110 VDC Other voltages 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz 48 VAC, 50/60 Hz 12 VAC, 50/60 Hz 24 VAC, 50/60 Hz Electrical entry Non-locking push type (Flush) Non-locking push type (Extended) Locking type (Tool required) Nil A B Grommet Grommet
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, H/PRECISION, ACTUATOR, MYH GUIDED CYLINDER, HE, 20MM MYH DBL ACTING AUTO-SW, .00000 lb
Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) Made to Order: Individual Specifications (For details, refer to pages 1538 and 1539.) 6 10 300 500 50, 100, 150, 200 50, 100, 150, 200, 250, 300 50, 100, 150, 200, 250, 300, 350 400, 450, 500 Symbol Specifications -X116 -X168 -X322 -X431 Hydro specifications 15 750 Helical insert thread specifications 20 25
Dimensions (mm) 1in = 25.4mm Scale: 50% With auto switch: MDSUA20-S 21.5 72 31 34.5 26.5 25.5 (34.5: Connector type) Angle adjustment bolt 2-M5 x 0.8 (Port position: Side port type only) A port B port 31 25 20.5 (26.5: Connector type) 50 65 Connector type 8 4 Connector type 10 Series MSUA Rotary Table High Precision Type Construction Single vane 180 (Indicates intermediate position) 90 (
/60Hz) Allowable voltage fluctuation 10% of rated voltage Coil insulation type Class H Power consumption W 50/60Hz VCB2: 4.9/4.1, VCB3: 7.7/6.6, VCB4: 10.5/9.3 Inrush VCB2: 22/19, VCB3: 36/30, VCB4: 45/37 Apparent power VA 50/60Hz VCB2: 10/8, VCB3: 15/13, VCB4: 19/16 Holding Note 1) Vibration resistance Conditions when tested with one sweep of 10 to 300Hz in the axial direction and at a