Option Specifications Vacuum pressure gauge specifications GZ30S Part number Fluid Pressure range Scale range (angular) Accuracy Class Operating temperature range Material Air 100 to 100kPa 230 3% F.S.
Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 PAKISTAN (Distributor) Jubilee Corporation First Floor Mercantile Centre, Newton Road Near Boulton Market P.O.
Environment Vibration resistance 10 to 55 Hz 1.5 mm amplitude X, Y, Z directions for 2 hrs. each Static Electricity Elimination Equipment Reduced-wiring Fieldbus System Impact resistance 100 m/s2 (approx. 10 G) X, Y, Z direction Water resistance Only display unit with cover is equivalent to IP65. It is equivalent IP40 without cover.
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator
Mesh: 100/70/50/25 mesh How to Order WF300 02 Port size Mesh 02 Rc1/4 03 Rc3/8 04 Rc1/2 Nil 100 mesh 1-X204 70 mesh 2-X204 50 mesh 3-X204 25 mesh Related Equipment Check Valve INA-14-290/XTO-674Water Regulator WR110--X224/WR110--X215 Body material: Brass Body material: Special brass Best Pneumatics 14-E627 Port size Set pressure range (-X224): 0.08 to 0.39 MPa Rc1/8, Rc1/4 Set pressure
First find the ratio of the discharge rate for fresh water when viscosity is 100 mPas from the graph above. It is determined to be 68%. 2. Next, in the required specification example, the viscosity is 100 mPas and the discharge rate is 12 L/min.
OUT1: Green OUT2: Red Enclosure IP40 Environment Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 1 minute between terminals and housing Insulation resistance 50 M or more at 500 VDC between terminals and housing Temperature characteristics
INFORMATION Compact Guide Cylinder With Flange 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 Plate side flange type added.
Note 2) Can set pressure with 4096 resolution, corresponding to the maximum setting pressure 100%. Note 3) Can monitor pressure with 4096 resolution corresponding to the maximum output pressure 100%. Glossary of Terms SERIAL NETWORKS SMC Serial Network Systems SERIAL NETWORKS SOLENOID VALVE MANIFOLDS What exactly is the difference between an open network and a closed network?
(MPa) VEX 0.25 0.25 0.20 0.20 AMR 0.15 0.15 ITV 0.10 0.10 IC 0.05 0.05 0 0 50 100 150 200 250 300 350 400 450 500 0 0 50 100 150 200 250 300 350 400 450 500 VBA Flow rate (/min (ANR)) Flow rate (/min (ANR)) VE VY1 G Pressure Characteristics PPA Inlet pressure: 2.0 MPa Outlet pressure: 0.8 MPa Flow rate: 60 /min (ANR) Inlet pressure: 2.0 MPa Outlet pressure: 0.3 MPa Flow rate: 60 /min (ANR
How to Order ZFA 100 01 Bracket Air suction filter Nil L None With bracket (1 pc. on the left) R With bracket (1 pc. on the right) Type (Recommended flow rate) L or R shows the left or right of the filter IN when viewed from front. 50 l /min (ANR) 200 l /min (ANR) 100 200 Port size ZFA100 B (ZFA200) B (ZFA100) 1 8 1 4 02 01 Thread type Nil T Rc How to Order Manifold NPTF F G Indicate both
Tank capacity Approx. 0.32 gal (1.2 L) Rc3/8 Rc1/4 Port size IN/OUT Rc1/4 (with plug) Drain Wetted parts material Stainless steel 303, Stainless steel 304, EPDM, Ceramics, PPS glass 30%, Carbon, PE, Polyurethane Single-phase 100 to 240 VAC 10%, 50/60 Hz Power supply Overcurrent protector 15 A 10 A (100 VAC) to 4 A (240 VAC) 8 A (100 VAC) to 3 A (240 VAC) Current consumption Alarm Refer to
For forced convection cooling: Set the value to a maximum 50% of the actually installed regenerative option capacity (W). Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.
For 11-LEFSH16A-100BR, enter "LEFS16A-100" and select LEFS16A-100. Caution When the parameter is selected for stroke which is longer than that of the actuator to be used, the Position entered in the step data must not exceed the actual actuator stroke range.
Cover Tightening Torque Tightening torque(Nm) Bore size (mm) 32 40 50 63 80 100 12.5 1.2 74.5 7.4 100 10 411 41 Reassemble the cover with the above tightening torques. 203
Cover Tightening Torque Tightening torque(Nm) Bore size (mm) 32 40 50 63 80 100 12.5 1.2 74.5 7.4 100 10 411 41 Reassemble the cover with the above tightening torques. 204
(Humidity) 2~40 (Relative humidity of 85% or less) Applicable compressor (as a guide) 11 2.2 3.7 5.5 7.5 5.5 3.7 2.2 1.5 0.75 (for screw style) (kW) Single phase, AC100/100 to 110 Single phase, AC100/100 to 110 Single phase, AC200/200 to 220 Power source (V) 50/60Hz 165 195 310 360 330 370 165 195 175 210 210 250 200 230 320 385 335 380 210 240 200 230 170 200 175 210 165 195 165 195 165
10st 15st 20st 250 Load weight W (g) 200 150 100 50 0 0 5 10 15 20 Eccentric distance L (mm) Construction Parts list o!
Rated pressure range ZQ1S-D51--AS ZQ1S-D32--AS ZQ1S-D52--AS ZQ1S-D31--AS 0 to 100 kPa Set pressure range 0 to 99 kPa Withstand pressure 0.2 MPa Fluid Air, non-corrosive metal, non-combustible gas Power supply voltage 12 to 24 V DC 10% Current consumption 35 mA or less [with power supply voltage of 24 V DC and switch output ON (with no load)] Ambient temperature range 5 to 50 C (with no freezing
L[]ZC[]3L[][][]A3 L[]ZC[]3M[][][]A3 L[]ZC[]3H[][][]A3 L[]ZC[]5HRated thrust (N) 196 or m ore 117 or m ore 72 or m ore Rated thrust (N) 80 or m ore 43 or m ore 24 or m ore Available stroke (mm) 1 200 (Std. stroke : 25/40/50/100/200 Available stroke (mm) 1 200 (Std. stroke : 25/40/50/100/200 [][][]A5 Feed screw lead (mm) 2 6 12 Feed screw lead (mm) 2 6 12 L[]ZC[]5MMounting direction Horizontal