(de-energized) 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Status LEDs Response time Hysteresis Power supply voltage Enclosure Operating temperature range Withstand voltage Insulation resistance Vibration resistance Impact resistance Noise resistance Note 1) For digital flow switch with unit switching function.
/Japanese 1 pc.), Y-strainer (40 meshes) 25A, Barrel nipple 25A, Anchor bolt xing brackets 2 pcs. (including 6 M8 bolts) Note 10) Weight (dry state) kg Approx. 180 Approx. 215 Approx. 280 Note 1) When the ambient temperature or circulating uid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 186-1).
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Precision Regulator IR1000-A/2000-A/3000-A Series How to Order 0 0 0 IR 1 01 BG r t y u e w q A ARJ Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specication is required, indicate in alphanumeric order.
Regulator IR1200-A/2200-A/3200-A Series How to Order 0 2 0 IR 1 01 BG r t y u e w q A ARJ Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specication is required, indicate in alphanumeric order.
Description Note IP200-02 Pilot valve unit Applicable bore size 50 or more 39020-23 Seal kit Ambient temperature: Standard (5 to 60) Applicable stroke 25 to 300 mm or less Sensitivity Note 2) Within 0.5% F.S. Linearity Note 2) Within 2% F.S. Hysteresis Note 2) Within 1% F.S. Repeatability Note 2) Within 1% F.S.
U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer Clean One-touch fittings Port size/Applicable tubing O.D.
Specifications: Q (Brass + Electroless Nickel Plating), Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 06 (6mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: Q (Brass + Electroless Nickel Plating), Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 10 (10mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: G [Stainless Steel (SUS304)], Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 04 (4mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: Q (Brass + Electroless Nickel Plating), Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 04 (4mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: G [Stainless Steel (SUS304)], Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 08 (8mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: Q (Brass + Electroless Nickel Plating), Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 08 (8mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: G [Stainless Steel (SUS304)], Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 06 (6mm), Port Size Applicable Tube: 02 (R1/4)
Specifications: G [Stainless Steel (SUS304)], Model: U (Branch "Y", Union "Y"), Applicable Tube OD: 10 (10mm), Port Size Applicable Tube: 02 (R1/4)
Body Size: 2000, Thread: Rc, Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Push-turn Locking Lever Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: S (Silencer), Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: F (G), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right
Body Size: 2000, Thread: N (NPT), Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Z (Name Plate and Pressure Gauge in Imperial Units)
Body Size: 2000, Thread: Rc, Port Size: 02 (1/4), Option: None, Voltage: 5 (24 VDC), Lead Wire: Y (Type Y, DIN Terminal w/Connector), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right