SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA5-21-051-00T"

9.8.1 Safety Standards . 9-21 9.8.2 Cautions for Export . 9-21 Chapter 10 Warranty . 10-1 10.1 Scope of warranty and liability to the product . 10-1 TOC-4 A_HEC-OM-K001-1.7 Chapter 1 Safety Instructions Chapter 1 Safety Instructions Be sure to thoroughly read and understand the important precautions defined in this manual before using this product. 1.1 Before using the Chemical Thermo-con

AFM20-D: Auto drain AFM30-D/ AFM40-D: Auto drain OPEN (Discharging drain) Drain cock OPEN Drain cock (Discharging drain) -21- 9. Trouble Shooting Refer to the sections [8. Operation and Adjustment] (P20-21), [10. How to Replace the Components] (P23-26) and [11. Disassembly Drawing] (P27).

Options 21 6. Structural Drawing and Replacement Part 21 7. Trouble Shooting 22 8. How to Replace the Products 23 9. Disassembly Drawing 24 10. Dimensions 25-29 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Scket width across flats Max.thread depth [mm] Model Bolt tightening torque [Nm] [mm] LEY25 M8x1.25 12.5 13 17 LEY32 M8x1.25 12.5 13 22 LEY63 M16x2 106 21 36 Soket LEY100 M20x2.5 204 27 27 Work fixed / Rod end male thread Max.

AC adapter AC cord Bracket B1 IZF Model 21 For IZF21 31 For IZF31 4 retaining bolts are included.

Contents MHF2-8D MHF2-8D1 MHF2-8D2 For guide: GR-S-010 (10g) Seal kit MHF8-PS MHF8-PS MHF8-PS-2 12, 20, 21 For cylinder: GR-L-005 (5g) Order with the order No. as parts No. 12, 20 and 21 are provided as a seal kit.

Spanner for AW10 is a compact spanner. 21 12 14 AW10 AW20(K) AW30(K) AW40(K) AW60(K) Assembly 2) Wrap the pressure gauge thread with the seal tape leaving 1.5 to 2 threads from the end. Wrap seal tape leaving 1.5 to 2 threads Spanner Nominal: AW10 AW20(K) AW30(K) AW40(K) AW60(K) 3) Mount the pressure gauge.

Specifications CY3B/CY3R Applicable series 20 to 40 Bore size 21 Series CY3B/CY3R Made to Order Specifications 2 Contact SMC for detailed specifications, lead times and prices.

Step designation BIT 5 8 Stp-no. bit4 20 BIT 6 21 Stp-no. bit5 8 BIT 7 9 Stp-no. bit6 21 22 Stp-no. bit7 9 35V DC max. + SET-ON 10 Temporarily stops the program run by means of the ON input. 3 Temporary stop READY HOLD 23 BUSY <2> 11 Performs an emergency stop when ON input stops. 16 Emergency stop (nonlogical input) ALARM STOP 24 COM 12 ALARM RESET 4 Alarm release Releases the alarm being

Stroke + 126 3.3 24 1 5 3 5.8 8 3 21 59 F 5H9 +0.030 0 depth 5 T-slot dimensions (2/1) 29.5 5H9 +0.030 0 depth 5 6 T-slot 4-M5 x 0.8 (for body mounting) thread depth 8 (11.5) 38 E Refer to page 299 for mounting.

KPY10-02 KPY10-03 KPY12-03 KPY12-04 4 7.5 7.5 10.4 20.7 18 D1 10 6 11 11 12.8 22.8 19.5 D1 14 8 12 21 21 15.2 26.3 21.5 D2 M 45 57 45 52 10 H 18.5 29.4 24 17 17 Connection threads 12 57 57 20.9 31.4 25 22 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

MHZ2-10D MHZ2-16D MHZ2-20D MHZ2-25D Kits include items 19, 20 and 21 from the table above MHZ20-PS MHZ16-PS MHZ25-PS MHZ10-PS Seal kits consist of items 19, 20 and 21 contained in one kit, and can be ordered using the seal kit number for each cylinder bore size. 3 Parallel Type/Standard Type Series MHZ2 Dimensions MHZ2-10 Scale: 90% 27 11.4 2-M3 x 0.5 thread depth 6 (mounting thread) +0.025

KPY10-02 KPY10-03 KPY12-03 KPY12-04 4 7.5 7.5 10.4 20.7 18 D1 10 6 11 11 12.8 22.8 19.5 D1 14 8 12 21 21 15.2 26.3 21.5 D2 M 45 57 45 52 10 H 18.5 29.4 24 17 17 Connection threads 12 57 57 20.9 31.4 25 22 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

24 4 18 20.7 10.4 7.5 7.5 D1 10 6 19.5 22.8 12.8 11 11 D1 14 8 21.5 26.3 15.2 21 21 12 D2 M 45 52 45 57 H 10 24 29.4 18.5 17 17 Connection threads 12 57 57 25 31.4 20.9 22 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

01 VXK 2 21 01 0 0 1 G 1 G R 1 5 AC DC Model Refer to the Table (1) shown below for availability.

Polyvinyl formal Exhaust filter 3 16 Heat treated Guide Stainless steel Stainless steel spring wire N.O. spring 4 17 Heat treated Finger Stainless steel Stainless steel spring wire N.C. spring 5 18 Heat treated Roller stopper Stainless steel Brass Electroless nickel plated N.C. holder 6 19 Lever shaft Stainless steel Stainless steel N.C. spacer 7 20 Nitriding Holder Brass NBR Rod seal 8 21

MHF2-16D MHF2-16D1 MHF2-16D2 20, 21, 22 MHF16-PS MHF16-PS MHF16-PS Seal kit MRHQ 3, 4, 5, 6, 14, 16, 19 Mounting screw MHF-A1602 MHF-A1602-1 MHF-A1602-2 Finger assembly MA Kit no.

Applicable Magnetic Field Resistant Auto Switches (Refer to page 21 and 22 for detailed auto switch specifications.)

Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions. Air Supply Handling Caution 1. Do not use a lubricator on the supply side of this product, as this can cause a malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this regulator. 2.