Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
(N.C.) port Port size Rc1/8 Supply from one side 10 NPT1/8 12 12 Supply from both sides 12 G1/8 Supply from one side 10 8 10 M50.8 Supply from both sides 12 10 12 Note) The number of stations shown above is to satisfy the specifications of the ejector performance at the standard supply pressure.
L dimension L dimension No. 6 7 8 2 3 4 5 1 0 7 185.5 0 98 2 3 4 5 6 7 1 0 0 8 198 1 110.5 6 7 8 4 5 2 3 1 1 9 210.5 123 2 M12 input block (n) 6 7 8 3 4 5 2 2 10 223 135.5 3 L dimensions 6 7 8 9 5 4 3 11 235.5 4 148 9 10 8 7 6 4 12 248 5 160.5 Connector type For M (m + n = 2 to 8) 10 8 9 7 5 173 6 10 11 9 6 11 10 7 12 8 Connector type For T (n = 1 to 8) 1686 Decentralized Serial Wiring (GW
10.2 8 10 17.8 11 5.5 2-3.3 Mounting hole Connector type: ZSP10X C Adjusting needle ADJ Pressure sensor Vacuum supply port 20 08 Adsorption nozzle port 7 48.3 Lead wire length 600 (3000) Adsorption nozzle port 0X: M5 x 0.8 0XY: M6 x 1 Vacuum supply port 0X: M5 x 0.8 0XY: M6 x 1 59.5 50 PV 6.5 10.2 8 5.5 17.8 11 10 2-3.3 Mounting hole 16-7-4
x 10-10 for the standard material (FKM) at ambient temperature, excluding gas permeation Leakage Pam3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperature, excluding gas permeation Flange type KF(NW) KF(NW),K(DN) Main material Body: aluminum alloy, Bellows: SUS316L, Main part: SUS304 and FKM (standard sealing material) Note 2 Surface treatment for body Outside: hard
8 24 76 46 66.5 101 66.5 68 99 VCB31 30 50 86 1/2 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101 71 68 104 22 45 90 1/4, 3/8 41 11 17 36 22.5 23 M5 8 26 84 48 74.5 103 74.5 70 107 VCB41 30 50 94 1/2 41 13.5 17 36 25 23 M5 8 26 88 48 78.5 103 78.5 70 111.5 35 60 102 3/4 41 17.5 17 36 30 28.2 M5 8 26 96 48 86.5 103 86.5 70 119 17-2-27
Temperature characteristics (25C reference) 2%F.S. (0 to 50C) 3%F.S. (10 to 60C) 3% F.S. (0 to 50C) 4% F.S. (10 to 60C) 5% F.S. (10 to 60C) Accuracy Enclosure IP65 Withstand voltage 500 VAC for 1 minute between terminals and housing Insulation resistance 100 M or more (500 VDC measured via megohmmeter) between terminals and housing Operating temperature range Operating: 10 to 60C, Stored:
System error Brown DC(+) Internal data error 12 to 24VDC + Black OUT Load Internal data error Blue DC() 6 Series ZSE30/ISE30 Dimensions 20 0.1 2-M3 x 0.5 Thread depth 4 Lead wire with connector 9.5 25 8 30 3.6 M5 x 0.8 MPa PRESSURE 20 0.1 10 SMC OUT Width across flats 12 SET 1.5 01: R 1/8 T1: NPT 1/8 With bracket 42.5 10 15 4.2 3 22 30 20 25 20 SMC 45 30 1.8 35 35 Panel mount 8 17.8 7.2
11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard strokes 20 25 32 M5 x 0.8 with depth 8 M5 x 0.8 with depth 8 M6 x 1.0 with depth 9 9.3 with depth 8 9.3 with depth 9 11 with depth 11.5 53 51.5 56 72 74.5 83 30 38 48 5 6 7 5 6 8 M6 x 1.0 M8 x 1.25 M10 x 1.25 5.5 5.5 6.6 16 20 24 13 23.5 29 20, 30, 40, 50, 60, 70, 80, 90,
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
10 VX 0 0 10 30 40 50 20 60 VX3 10 20 Discharge rate (l/min) Discharge rate (l /min) VXA Selection from Flow Characteristic Graph (PA3000) VN Required specifications example: Find the pilot air pressure and pilot air consumption for a discharge rate of 6 l/min and a total lifting range of 25 m.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. -69No.PS-OMU0003-D Problem No.
For detecting fine pressures, warm up the product for 10 to 15 minutes. Check if the product satisfies the specified accuracy after 10 minutes warm up time. Insufficient warm-up time Product failure Replace the product. -70No.PS-OMU0006-D Problem No.
Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3
Part number of the pressure gauge with a nipple assembled is G27-10-M5-X215. How to Order M5 ARJ 10 BG 1 2 Option Miniature regulator 1 0.2 MPa seting S With seal ARJ210-M5 Note 1) Compared with standard specifications, its adjusting spring has only been changed. It is not the product which does not allow the pressure more than 0.2 MPa. Adjusting spring is not replaceable.
Model No.: EX9-AWTS (M12 connector for socket 10 pieces.) Fig. 10-4 EX9-AWTS Note: Tighten the seal caps to the tightening torque specified (0.2 Nm). -54No.EX##-OMU0020-A Model No.:EX245-AWP (10 pieces for Push Pull connectors of power connection) The EX245-AWP can be used with the EX245-SPN1/EX245-SPN2. Mount the seal cap in the unused connector.
Ports 2, 4 size (metric) Ports 2, 4 Symbol C3 C4 C6 M5 CM Ports 1, 3, 5 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting M5 threads Mixed size/with port plug Top ported elbow 3.2 One-touch fitting Top ported elbow 4 One-touch fitting Top ported elbow 6 One-touch fitting M5 threads Bottom ported elbow 3.2 One-touch fitting Bottom ported elbow 4 One-touch fitting Bottom ported
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.