10 4 3 5 12 "O" ring NBR 13 Piston seal NBR Replaceable parts list (Seal kit) Bore size (mm) Part no.
P2) Port size: refer to table below C K (External pilot solenoid) P1 P2 J J B (Air operated) D 4 x 2 x 18 mouting hole 32 H F A Applicable flange Port 1, 2 Pilot port 12(P1), 10(P2) A Model B C D E F H J K Note) VNC5-32F VNC6-40F VNC7-50F 1 8 1 4 1 4 32 40 50 292.5 (294.5) 308 (310) 332 (334) 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 Note)
Allowable load Table 7 0.044mAllowable moment OK Moment of inertia Find inertial moment of load to calculate I=m(a2+b2)/12+m2 I=0.15(0.062+0.042)/12+0.150.032 energy. Find I.
Specification for Option V 12 1 Safety instructions . 12 -1 12 2 Specifications . 12 -1 12 3 How to perform maintenance. 12 -2 12 4 Electric circuit . 12 -2 Chapter 13 Service Record 13 1 Service Record . 13 -1 Table of Contents 2 IDX-OM-W034 Air Dryer i Safety Instructions i Safety Instructions Before use,read and comprehend important cautionary notification well on this operattion manual
(2-color indicator) 2-wire 12 V 24 V Grommet Yes Relay, PLC 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V 2-wire 12 V 3-wire (NPN equivalent) Reed auto switch Z76 IC circuit 5 V Yes Grommet 100 V Z73 IC circuit Relay, PLC 24 V 12 V 2-wire Z80 100 V or less Lead wire length symbols: 0.5 m Nil (Example) Y7BW 3 m L (Example) Y7BWL 5 m Z (Example) Y7BWZ Solid state auto switches marked
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
Bore 1/32 1/16 1/8 1/4 3/8 1/2 3/4 1 1 6 15 37 1-1/8 5 12 28 85 1-1/2 3 7 16 50 2 4 9 28 70 2-1/2 6 18 45 72 3 4 12 30 48 3-1/4 3 10 24 37 79 4 7 17 28 60 5 4 11 18 40 82 6 3 7 12 26 55 8 4 7 15 32 10 4 9 20 12 3 6 14 NOTE: These values are an approximate speed, under average conditions, where the force required is 50% of available 80-100 PSI inlet pressure, the directional valve internal
I-MU02 I-MU03 I-MU04 I-MU05 E1 16 18 20 28 A1 10.5 12 14 18 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 A1 10.5 12 14 18 L1 27 31 36 46 E1 14 18 20 28 L1 27 31 36 46 MM M10 x 1.25 M12 x 1.25 M14 x 1.5 M18 x 1.5 NDH10 8 10 10 14 Size 25 32 40 50 Size 25 32 40 50 +0.058 0 +0.058 0 +0.058 0 +0.070 0 Applicable pin no.
57.2 59 65 70.8 76 76.9 81.3 3.4 4.4 5.1 6.1 5.2 6.3 6.7 8 7.4 8.2 9.8 10.9 10.3 11.3 7.9 11.1 11.8 12.8 12.3 13.4 16.3 17.6 19.3 20.1 21.7 22.8 22.7 23.7 20.9 23.8 24.5 25.5 28.9 30 33.2 34.5 38.6 39.4 41 42.1 51.6 52.6 11 9.8 5 6.7 9.8 10.1 12.3 11.5 12.3 15.7 16.1 8.8 2 3.2 4 6 4 6 6 8 6 8 10 12 10 12 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2 15.2 18.5 20.9 18.5 21.7 12.7 3.3 5.5 9.1 11
Check if there is a noise source nearby. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range 12 to 30 VDC. "HHH" is displayed. 6 (1) Reset applied pressure to a level within the set pressure range. (1) Check if the pressure exceeds the upper limit of the set pressure range. "LLL" is displayed.
EX245-SPN1 GSD . 41 EX245-SPN1 Diagnostics type 1 4 (IN) 1 5.1.1. Diagnostics type 1 Diagnostics type 2 4 (IN) 1 5.2.2. Diagnostics type 2 Valves (16 coils) 2 (OUT) 12 6.3. Valves (32 coils) 4 (OUT) 12 EX245-DX1-X36 2 (IN) 210 7.4. EX245-DY1-X37 1 (OUT) 210 8.4.
12 bit Ry1B Ry1A Ry19 Ry18 ID 1 0 0 0 1 2 0 0 1 0 3 0 0 1 1 12 1 1 0 0 44 - 13.
(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133
LVC Refer to pages 17-3-40 and 17-3-41 for specifications and models.
(Er0, 4, 6, 7, 8, 9) is displayed. (2) Check if the power supply voltage is in the range 12 to 30 VDC. (2) Supply power in the range "HHH" is 6 12 to 30 VDC. displayed. (1) Reset applied pressure to (1) Check if the pressure exceeds the a level within the set pressure range.
(mm) P = Operating pressure [MPa] T 0425 T 0604 TU 0805 T 0806 1/8B T 1075 TU 1208 T 1209 1/4B TS 1612 3/8B T 1613 1/2B 3/4B 1B 4.9 4 2.5 l = Length of piping [mm] 12.6 6 4 a = Internal cross section of piping [mm ] 19.6 8 5 QC = Air consumption required for one reciprocation of rotary actuator [l (ANR)] 28.3 8 6 33.2 6.5 44.2 10 7.5 50.3 12 8 63.6 12 9 66.5 9.2 113 12 16 127 12.7 133
M D2 L A D1 NPT, R(PT) Nylon Urethane M5 0.8 M6 1.0 KSH04-M5 KSH04-M6 KSH04-01S KSH06-M5 KSH06-M6 KSH06-01S KSH06-02S KSH08-01S KSH08-02S KSH08-03S KSH10-02S KSH10-03S KSH10-04S KSH12-03S KSH12-04S 36.5 9 12 37 33 8 16 10.4 2.5 4.0 4.0 4 38 37.5 38 39.5 42.5 44 47 48 54 55 57.5 57 60 1 8 M5 0.8 M6 1.0 14 34 33.5 34 35.5 36.5 40 41 41.5 48 48.5 49.5 50.5 52 12 2.5 3 4.0 4.0 5.6 5.6 12 8 6
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 505 Applicable Fluids Material and fluid compatibility check list for High