SMC Corporation of America
Elite Part Number Search
Search Results "LEKFS16EA-300"

Dimensions Formulae L1 = 16n + 53 L2 = 16n + 87 n: Stations (max. 16 stations) L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 L2 (L3) (L4) 85 119 150 160.5 101 135 162.5 173 117 151 175 185.5 133 167 187.5 198 149 183 212.5 223 165 199 225 235.5 181 215 237.5 248 197 231 262.5 273 213 247 275 285.5 229 263 287.5 298 245 279 300 310.5 261 295 325 335.5 277 311 337.5 348 293 327 350 360.5 309

SMC PRESSURE SWITCH PD PV 57 1 67 1 32.4 109 Approx. 300 Ejector RESET SET Supply valve Release valve V 21.2 Manual override Suction filter 1 2-4.6 (mounting hole) 1 5.6 1 8 1 10.2 123 1 4.6 1 8 SOL. c SOL. a Silencer SOL. b Interface A Light Suction filter Manual override Interface B Digital vacuum pressure switch M5 port PE (pilot valve exhaust port) M5 port PD (vacuum breaking pressure

needle 6 One-touch fitting Port V 67 35.3 Supply port 6 One-touch fitting Port P1 ZYY35LZ-10S1 (specifications without vacuum switch) End plate (P44027A) Manual override 3 31 51.4 In case of locking type, turn after pushing in. 13.5 5.25 16.5 55.5 Manual override In case of locking type, turn after pushing in. 117.1 Approx. 300 (Lead wire length) 10 Series ZYY/ZYX Ejector Valve Dimensions

This is a legacy product, and replaced byPSE201A-A4C PSE200/300/530-560. CONTROLLER, PRESSURE SENSOR. INSTRUMENTATION. PSE200/300/530-560 OTHER SIZE. 1.08881 lb. 1X.

Sensor Pressure Control Pressure Sensor Dimensions 48 x 48 x 100.5 Power supply 12 to 24 VDC (15 W or more), Ripple (p-p) 1% or less qNo. of inputs: Up to 10 bit input from sequencer (parallel) Note 5) Input method: No-voltage contact or NPN open collector input Input Minimum pulse width: 50 msec wInput method: 4 point input with keys (Interval time can be set by programming.) 12 VDC (Max. 300

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,  140, 160 , Standard stroke (mm): 10 through 300 , Through hole mount, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, 300 lb

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125,  140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types:  Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, 300 lb

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, double rod, large bore, Bore size (mm): 125,  140, 160, 180, 200, Standard stroke (mm): 10 through 300, Port thread types:  Rc, NPT, G, Auto switch capable, Compact Cylinder, NCQ2-Z, COMPACT CYLINDER, E38, 300 lb

1%F.S., Proof pressure: 50kPa, Analog output: 1-5VDC, 4-20mA DC, PRESSURE SENSOR,L/DIFFERENTIAL, INSTRUMENTATION, PSE200/300/530-560, 1X, PSE200/300/530-560 OTHER SIZE, .25743 lb

0.2%F.S. or less, Enclosure: IP40, SENSOR, CLEAN RM, INSTRUMENTATION, PSE200/300/530-560, 15, PSE200/300/530-560 OTHER SIZE, 0.2354 lb

Refer to the Installation / Operation manual for details Table 2.5-3 Monitoring method for contact input Contact input delay timer for reading Monitoring method 0 sec Continuous monitoring 1 to 300 sec Monitor only during operation 2.5 Contact input signal HRR Series 2-14 HRX-OM-W004 Chapter 2 Contact input/output communication Operation start Operation stops due to the alarm.

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.

How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specifications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.

Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.

Auto switches are shipped together, (but not assembled). 2 JCQ Series Specifications Bore size [mm] 12 16 20 25 32 40 50 63 80 100 Action Double acting, Single rod Fluid Air Proof pressure 1.0 MPa Maximum operating pressure 0.7 MPa 1 Minimum operating pressure 0.07 MPa 0.05 MPa Ambient and fluid temperature 5 to 60C Lubrication Not required (Non-lube) Piston speed 50 to 500 mm/s 1 50 to 300

assembled). 3 Compact Guide Cylinder JMGP Series Specifications Bore size [mm] 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) Action Double acting Fluid Air Proof pressure 1.05 MPa Maximum operating pressure 0.7 MPa1 Minimum operating pressure 0.15 MPa Ambient and fluid temperature 5 to 60C Piston speed Note) 50 to 300

Conversion cable P5062-5 (Cable length: 300 mm) 300 * To connect the teaching box (LEC-T1-3mGm) or controller setting kit (LEC-W2) to the controller, a conversion cable is required. 7 JXCE1/91/P1/D1 Series Precautions Related to Differences in Controller Versions As the controller version of the JXC series differs, the internal parameters are not compatible.

Fixed end Maximum Operating Pressure How to Order Inch size TID01 8 2.0 1.8 Max. operating pressure MPa TID07 Length per roll 1.6 Symbol 8 16 Length 8 m (25 ft) roll 16 m (50 ft) roll TID01/TID05/TID11 1.4 1.2 TID13 1.0 Tubing model 0.8 0.6 0.4 0.2 0.0 20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Operating temperature C 510 TL/TIL/TD/TID Series Applicable Fluid List Chemical

500 400 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] AFM40-A AFD40-A P1=0.5 MPa P1=0.3 MPa 0.04 0.04 P1=0.7 MPa P1=0.3 MPa P1=0.7 MPa P1=0.5 MPa 0.03 0.03 Pressure drop [MPa] Pressure drop [MPa] 0.02 0.02 P1=0.5 MPa P1=0.5 MPa P1=0.3 MPa P1=0.3 MPa P1=0.7 MPa 0.01 0.01 P1=0.7 MPa 0 0 0 0 100 200 300 500 400 600 200 800 1000 400 600 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 57

Influence Unit Item Standard value Corrosion Scale Operating Environment/Storage Environment Warning generation p p p p p p pH (at 77F (25C) 6.0 to 8.0 100to 300 Electrical conductivity (77F (25C) [S/cm] 1. Avoid using the Thermoelectric Bath in an environment where it could be splashed by fluids (including mist) such as water, salt wa-ter, oil, chemicals, or solvents. 2.