Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-15-1

CEP112 CEP120

Name Material Remark 1 Body A PBT 2 Body B Brass Electroless nickel plating 3 Handle POM 4 Needle POM 5 End cover Brass Electroless nickel plating 6 Spring Steel wire 7 U-seal HNBR 8 O-ring NBR 9 Needle O-ring NBR 10 Y seal NBR 11 Seal for fitting NBR 12 Cassette 13 Stator POM 14 Valve O-ring HNBR 15 Shaft O-ring NBR 16 Seal NBR For G thread only. 10 - AS*2Q R thread / NPT thread type G thread

Bracket mounting dimensions B S (Width across flats) O. D.

JMHZ2-16D-X7400B-ASSISTA(-P) mm 16 MPa 0.1~0.7 (oC) -10~50 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 (g) 680 D-M9(N/P)-5 ISO9409-1-31.5-4-M5 (www.smcworld.com)JMHZ2 Series P .15 M12 8 6 - 3-2. 2 1 F 7 - 3-3. H 8 - 3-4. () P11P12P13 8 8 4 27 17 9 - 3-5. M12 8 () PIN 1 GND DC0V 2 +24V DC24V 3 ON/OFF 4 ON/OFF 5 6 7 8 3-6.

Node address setting, Communication speed setting 1) Turn on (SW mode) the switch No. 10 of the 10-digit switch mounted on the SI unit. 2) Change the instance attribute value via the network as indicated below.

Refer to pages 15-18-3 to 15-18-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-9-9

When the output pressure is 100%, the set pressure value is 0x0FFF. 8 - Diagnostic information This product can detect the device error by diagnostic Bit in the process data. 2 3 BYTE 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Disabled SSC1 Value Abnormal Warning Notifi cation Bit offset Item Details 0 SSC1 1: Output pressure value is within +/-10% of the target value. 0: Other than the above

IN OUT 01 ARJ 3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Body size Option specifications 0.7MPa setting (standard) 0.2MPa setting With thread sealant Nil 1 S Model Relieving type 10 When set at 0.2MPa, a pressure gauge is not included.

Varistor 2) From the terminal block (3), loosen the screw (11), then pass the lead wire (10) through, then again tighten the screw (11). Neon bulb When 100 VAC or more Coil Note 1) The tightening torque should be within 0.5Nm +/15%. Note 2) Cable (7) external: 6 to 8 mm. Note 3) Crimped terminal like round-shape or Y shape cannot be used.

Part Number: EJE-NAMUR-6100 IP5 Accessories Type IP6000 has standard lever for stroke (10~85mm) 000 Lever type feedback Nil None (standard) Rotary cam feedback 100 A 0.7 Output restriction with pilot valve Accessory for IP6000, 6100 small capacity actuator 3/4 Input Pressure 3-15 psi 0 B 1.0 Output restriction with pilot valve 1/2 split 3-9, 9-15 psi 1 E For stroke 35~100 mm with lever unit

Note 3) 10 to 15 in decimal number are displayed as follows in the 7-segment LED. Decimal display Hexadecimal display 10 A 11 b 12 c 13 d 14 E 15 F Note 4) Applicable to non-magnetizing lock 47

The voltage variation must stay within the -10 to +10% range of the rated voltage.

P FR (2) 6 8 12 16 20 25 10, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50, 75, 100, 125, 150 FP Note 2) W/ end lock is not available in Series MXQ6.

Standard dew point -20oC, -15oC : about 10 min. Selection Caution a. Do not obstruct the purge air discharge ports. Dehumidification performance will decrease or may become impossible if purge air back pressure becomes too high or purge air stops flowing. b. Provide proper filtration on the inlet side of a membrane air dryer.

Standard dew point -20oC, -15oC : about 10 min. Selection Caution a. Do not obstruct the purge air discharge ports. Dehumidification performance will decrease or may become impossible if purge air back pressure becomes too high or purge air stops flowing. b. Provide proper filtration on the inlet side of a membrane air dryer.

Standard dew point -20oC, -15oC : about 10 min. Selection Caution a. Do not obstruct the purge air discharge ports. Dehumidification performance will decrease or may become impossible if purge air back pressure becomes too high or purge air stops flowing. b. Provide proper filtration on the inlet side of a membrane air dryer.

As a guide, insert bolts in 2 locations for 2-5 stations, 3 locations for 6-10 stations, 4 locations for 11-15 stations, and 5 locations for 16-20 stations. 2. When using the manifold with DIN rail in an environment where any vibration or impact is applied to it, the DIN rail itself may be broken.