Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0906 (5/16" x 0.236"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0704 (1/4" x 5/32"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D. x I.D.: 0325 (5/32" x 0.098"), Port Size for Tubing O.D.: N01 (1/8" Thread Connection), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 07 (1/4"), Port Size/Applicable Tube: N01 (1/8" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 03 (5/32"), Port Size/Applicable Tube: N01 (1/8" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 01 (1/8"), Port Size/Applicable Tube: N01 (1/8" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 09 (5/16"), Port Size/Applicable Tube: N01 (1/8" Thread), Sealant: S (Sealant)
Model: L (Male Elbow, Union Elbow), Applicable Tube O.D.: 11 (3/8"), Port Size/Applicable Tube: N01 (1/8" Thread), Sealant: S (Sealant)
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(
Note 3) Not available for piping specifications of 01 and N01.
min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) Effective area (mm2) 23, 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321F AS331F AS421F AS431F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 12, 13 10, 11 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 10, 11, 12 Effective
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: D (Panel Mount Adapter + Front Protection Cover)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
AV Regulating pressure range AU Ambient and operating temperature range Weight AF Model AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size Model IR IN OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 Rc 1/8 R 1/8, M5 x