Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate
Pressure Range: -100.0 to 100kPa, Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: -, Calibration Certificate: -
Pressure Range: -100.0 to 100kPa, Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certificate: -
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: Female Thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range(%): 35~85, Number
Type: Pressure Switch, Fluid Type: Air, Sensor, Monitor Structure: [Integrated Type] Integrated shape, Analog Output Specification: -, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [NPT] NPT, Plumbing Thread Nominal: [1/8] 1/8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range(°C): -5~50, Operating Humidity Range
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, PRESSURE SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X, OTHER
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
ZSE10 compact, digital pressure switch for vacuum/compound pressure has been reduced in height by approximately 50% when compared to the ZSE30A.? Up to 10 slave sensors can be set at once using the copy settings function.? Options include?direct mount, panel mount?or DIN rail mount, and a choice of 2 piping directions.?, OTHER NO SIZE RATING, VACUUM SERIES, ZSE30 VACUUM SWITCH, 2X,
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: w/o Lead Wire, Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: M5 Female Thread, Option 1: w/o Lead Wire, Option 2: Panel Mount Adapter, Option 3: -
10%, Ripple (p-p) 10% or less (With power supply polarity protection)40 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (With NPN output)2 V or less (With load current of 80 mA)2.5 ms or less (Response time selections with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note)Variable (0 or above) Note)0.6 to 5 V ?
Series: 1 (JSY1000), Type: 41 (Bottom Ported), Valve Stations: 8 Stations, P,E Port Entry: B (Both Sides), A,B Port Size: M5 (M5 x 0.8)