Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Rod Piping/Male Thread, Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 20mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

The ZCUK series is a non-rotating free mount cylinder for vacuum applications. The ZCUK was created by providing a vacuum passage in the rod of the CUK cylinder to enable a vacuum pad to be installed on the end of the rod. A guide is provided as standard equipment. Vacuum pads are available with pad diameters of 2 to 50. Cap or rod piping is available to the rod side. Series ZCUK is available

Magnet: Built-in Magnet, Mounting: Standard, Through-hole, Bore Size: 50mm, Stroke 1: 20mm, +: +, Stroke 2: 40mm, Body Option: Standard, Rod End Female Thead, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: S (24VDC; Conduit w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: C (110VAC; Grommet w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: E (230VAC; Grommet w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: J (110VAC); DIN Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: G (24VDC; DIN Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: M (24VDC; Conduit Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: H (100VAC; DIN Terminal w/Surge Voltage Suppressor)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: L (230VAC; DIN Terminal w/Surge Voltage Suppressor)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, FREE MT, W/VACUUM, ACTUATOR, ZCU COMPACT CYLINDER, HE, 20MM ZCU DBL-ACT AUTO-SW, .66138 lb, ModelBore size (mm)Cylinder stroke (mm) 510152025304050ZC(D)UKQ1049(54)53(63)57(67)61(71)65(75)69(79)??

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, FREE MT, W/VACUM, ACTUATOR, ZCU COMPACT CYLINDER, HE, 20MM ZCU DBL-ACT AUTO-SW, .66138 lb, ModelBore size (mm)Cylinder stroke (mm) 510152025304050ZC(D)UKQ1049(54)53(63)57(67)61(71)65(75)69(79)??

The ZCUK series is a non-rotating free mount cylinder for vacuum applications. The ZCUK was created by providing a vacuum passage in the rod of the CUK cylinder to enable a vacuum pad to be installed on the end of the rod. A guide is provided as standard equipment. Vacuum pads are available with pad diameters of 2 to 50. Cap or rod piping is available to the rod side. Series ZCUK is available

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: A (24VDC; Grommet), Other Voltages and Electrical Options: None, Other Options: B (NPT Thread)

Size, Body, Valve Type: 40D (Size: 1; Body Mat'l: Aluminum; Port Size 1/4; Orifice Dia: 2, N.O.), Voltage and Electrical Entry: A (24VDC; Grommet), Other Voltages and Electrical Options: None, Other Options: A (G Thread)