Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: Latching Positive Common, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2%
Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 100 to -100kPa/NPN Open Collector 1 Output + Analog Voltage, Suction Filter, Vacuum Pressure Switch Unit Specs: Unit Switching Function, Vacuum Pressure Switch Lead Wire: No Connector, Fitting, P Port: 1 [ø3.2 (Straight)], Fitting, PS/PV Port: 0 [w/o Fitting (M5
Nozzle Diameter: ø1.0, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: Suction Filter Only, Vacuum Pressure
Nozzle Diameter: ø1.0, Exhaust: Silencer for Manifold, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 0 to -101kPa/NPN Open Collector 2
Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 100 to -100kPa/NPN Open Collector 1 Output + Analog Voltage, Suction Filter, Vacuum Pressure Switch Unit Specs: Unit Switching Function, Vacuum Pressure Switch Lead Wire: No Connector, Check Valve: None, Fitting (V Port): 1 [ø3.2 (Straight)], Fitting (P Port): 0 [w/o Fitting (M5
Nozzle Diameter: ø1.0, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: Suction Filter Only, Vacuum Pressure
Nozzle Diameter: ø0.7, Exhaust: Silencer for Manifold, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: Suction Filter Only, Vacuum Pressure
Nozzle Diameter: ø0.5, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: Suction Filter Only, Vacuum Pressure
Nozzle Diameter: ø0.7, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: Latching Positive Common; Vacuum Release Valve: N.C., Voltage: 24VDC, Electrical Entry: L Plug Connector, Lead Wire Length 0.3m, Light & Surge Suppressor, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 100 to -100kPa/NPN Open Collector
Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 14, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Manifolds, Operating Pressure Range(
Main Body Shape: Unit, Additional Function: Silencers / Filter, Ultimate Vacuum(kPa): -80, Air Consumption Flow Rate(l/min): 46, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø6, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Operation Category: Normally Closed, Application: Manifolds, Operating Pressure Range(
.) / 8.5 (latching), Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: M5, Application: Individual Item, Performance: Large Flow Rate Type, Operating Temperature Range(°C): -5~50, Suction Flow(l/min): 3.5, Nozzle Diameter: 0.4mm, Exhaust specifications: Port exhaust (individual exhaust), Combination of supply
.) / 8.5 (latching), Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: M5, Application: Individual Item, Performance: Large Flow Rate Type, Operating Temperature Range(°C): -5~50, Suction Flow(l/min): 3.5, Nozzle Diameter: 0.4mm, Exhaust specifications: Port exhaust (individual exhaust), Combination of supply
Main Body Shape: Unit, Additional Function: Filter / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -90, Air Consumption Flow Rate(l/min): 6.5 (N.C.) / 8.5 (latching), Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Application: Manifolds, Performance: Large Flow Rate Type, Operating Temperature Range(°C
Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries. Due to the compact design of the ZA, it is possible to install on moving parts. The shortened tube length to pad improves response time. The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters. Compact
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This product is obsolete. Please contact us for the latest version.sales@ocaire.com
Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries. Due to the compact design of the ZA, it is possible to install on moving parts. The shortened tube length to pad improves response time. The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters. Compact
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S