01 01 01 01 01 01 01 01 01 01 01 01 01 01 153.5 156.5 189.5 192.5 118.5 123.5 01 153.5 158.5 01 01 01 189.5 194.5 01 55 Series ZP Heavy-duty Pad Dimensions: With Buffer 40 50 01 ZPT HB -A18 01 ZPT HB -A18 63 80 01 ZPT HB -A22 100 125 1/8 (Rc, NPT, NPTF) Width across flat 17 (Hexagon) M22 x 1.5 50 24 1/8 (Rc, NPT, NPTF) Width across flat 14 (Hexagon) 1/8 (Rc, NPT, NPTF) Width across flat

" M5 x 0.8 18.3 23.1 12 12.7 7 13.5 AS121F-U10/32-07 AS221F-01-04 9.3 27.5 20.4 4 1/4" 10-32UNF 14.3 17 AS221F-01-01 AS221F-01-06 27.5 27.5 6 20.4 11.6 20.4 36.1 32.1 27.1 13.5 31.1 9.3 1/8" 14.2 12 (12.7) 1/8 16 12.7 AS221F-01-03 AS221F-01-08 32.4 8 20.4 15.2 18.5 19 27.5 25.3 17 9.3 5/32" 12 (12.7) AS221F-01-05 AS221F-01-10 14.2 14.3 40.2 10 23.1 18.5 21 15 21 30.2 36.1 31.1 27.1 33.1 17

Connect the communication cables with P1 and P2. P1 (D-sub 25P female) Cap P2 (D-sub 9P female) P3 (D-sub 9P male) Not used. (Only for maintenance) Power cable Contact signal cable Serial RS-485 communication cable Figure 3-10 Power Cable Insertion and Communication Cable Connection Correct phase rotation is required when attach the power cable to the breaker terminal.

Connect the communication cables with P1 and P2. Cap P1 (D-sub 25P female) P2 (D-sub 9P female) P3 (D-sub 9P male) Not used. (Only for maintenance) Power cable Contact signal cable Serial RS-485 communication cable Figure 3-7 Power Cable Insertion and Communication Cable Connection Correct phase rotation is required when attach the power cable to the breaker terminal.

Remove the gauge and balance the bridge circuit (P1 = P2) by adjusting the variable orifice (S3) via the adjustment knob. By moving the work piece away from the nozzle (S4) a pressure differential (P1 P2) is created. As soon as the work piece is moved within the detection range of the AirCatch Sensor the back pressure P2 increases.

When the work piece comes close to the detection nozzle, the back pressure P2 increases until it is larger than P1 (P2 > P1). Then the switch output turns on to notify that the pressure is below the detection gap.

length) 63.6 [65.8] 107.5 [109.7] (Light/Surge voltage suppressor) 54.2 69.6 [76.6] 50.1 [57.1] + 45 34.7 8.5 31.5 21.5 6 6 17 17 43.9 15 1/8 (P, R port) 45.5 32 24 L plug connector (L): SYJ5140-L-01 M plug connector (M): SYJ5140-M-01 DIN terminal (D): SYJ5140-D-01 M8 connector (WO): SYJ5140-WO-01 Applicable cable O.D. 3.5 to 7 Approx. 300 (Lead wire length) 82.9 82.6 Max. 10 75.4 50.1 [

M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX

M plug connector 2 position double: VZS3250-M(Z)-01 02 3 position closed center: VZS3350-M(Z)-01 02 3 position exhaust center: VZS3450-M(Z)-01 02 3 position pressure center: VZS3550-M(Z)-01 02 DIN terminal 2 position double: VZS3250-D(Z)-01 02 3 position closed center: VZS3350-D(Z)-01 02 3 position exhaust center: VZS3450-D(Z)-01 02 3 position pressure center: VZS3550-D(Z)-01 02 164 (3 position

pilot port (Only external pilot style(R)) 3 4 5 3 4 5 L plug connector (L): VQZ2 5 (R)lLl 0 1 01 02 0 1 01 02 DIN connector (Y): VQZ2 5 (R)lYl Indicator light 148<150> 300 (Lead wire length) 67.5<68.5> Applicable cord O.D. 3.5 to 7 Pg.7 155.5 MAX.10 53<56.5> 71.5 Indicator light Cover diameter 1.5 Cross section 0.23mm2 < >: AC 82.5 75 3 4 5 M plug connector (M): VQZ2 5 (R)lMl 0 1 01 02

Note 2) Specify wiring type of each station on the manifold In the case of the 16-output SI unit Symbol 01 Stations Note 1 station specification sheet. Double wiring Note 1) 08 01 8 stations 1 station Specified layout Note 2) (Available up to 16 solenoids) Note 1) Indicate the sizes on the manifold specification sheet in the case of CM.

Note 2) Specify wiring type of each station on the manifold In the case of the 16-output SI unit Symbol 01 Stations Note 1 station specification sheet. Double wiring Note 1) 08 01 8 stations 1 station Specified layout Note 2) (Available up to 16 solenoids) Note 1) Indicate the sizes on the manifold specification sheet in the case of CM.

(mm) H A (1) Weight (g) Thread R(PT) D1 D2 P2 L2 L3 M P1 L1 Part No.

The small pressure difference (P2 P1) that is created when a part is picked by the (S4) picking nozzle and is detected by the pressure sensor. Wiring is the same as ZSE2. AMJ Vacuum source Pressure sensor Filter case AMV Caution AEP Adsorption nozzle (0.3 to 1.2) 1. The case is made of polycarbonate.

As a guide, when W + P0a>P0A, adjust P1 to make W + P1a = P0A. W: Load (N) P0: Operating pressure (MPa) P1, P2: Reduced pressure (MPa) a: Rod side piston area (mm2) A: Head side piston area (mm2) Warning Since CJ2X, CUX10 are subject to internal leakage due to their construction, the speed may not be fully controlled with the meter-out controller () during low speed operation.

(P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor Q P P1 P2 S Cv 9 10 Series VCW Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.

R1 1 ZX1 06 R ZZX1 Supply port location 01 1 Stations Arrangement (First station from the right end of the valve side is station 1.)

Q=14.2Cv 10.2 P l/min Formula based on effective area (Smm2) Q=0.8S 10.2P l/min Q P P1 P2 S Cv : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm2) : Cv factor 4.5-11 Series VCW 2 Port Solenoid Valve for Fluid Control Be sure to read before handling.