Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: N (NPT)
Function: 1 (2 Position Single), Body Style: 20 (Body Ported/Individual Pilot EXH), Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 4 (220VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1), Thread: T (NPTF)
Size: Port Size 3/4, Number of Ports: 2 Port, Valve Type: 3 [NC (Operating Pressure 7.0MPa)], Gasket: NBR Seal, Thread: NPT, Port Size: 3/4, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Bracket: -, X200: -
Function: 2 Position Single, Piping: Body Ported/Individual Pilot EXH, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Option: -
Function: 2 Position Single, Body Style: Body Ported/Individual Pilot EXH, Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1, Option: -
Size: ø50, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: Rc, Port Size: 2, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Size: ø40, Valve Type: 1 [NC (Operating Pressure 1MPa)], Sealant: NBR, Thread: NPT, Port Size: 1 1/2, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Manual Override: -, Bracket: -, X200: -, CE Compliant: -
Solenoid: No.1 Solenoid, Body Option: 20A, Style: Energized Open/N.C., Option: Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil, Port Size: 06 [3/4 (20A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.2 Solenoid, Body Option: 25A, Style: Energized Open/N.C., Option: Stainless Steel Body & Shading Coil, PTFE (FPM) Seal, Class H Coil, Port Size: 10 [1 (25A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.2 Solenoid, Body Option: 32A, Style: Energized Open/N.C., Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 12 [1 1/4 (35A)], Thread: G, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Option: 50A, Style: Energized Open/N.C., Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: Flange 50A, Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.1 Solenoid, Body Option: 15A, Style: Energized Closed/N.O., Option: Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil, Port Size: 04 [1/2 (10,15A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.1 Solenoid, Body Option: 15A, Style: Energized Open/N.C., Option: Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil, Port Size: 04 [1/2 (10,15A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Option: 40A, Style: Energized Open/N.C., Option: Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil, Port Size: Flange 40A, Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Option: 50A, Style: Energized Open/N.C., Option: Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil, Port Size: 20 [2 (50A)], Thread: G, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.2 Solenoid, Body Option: 25A, Style: Energized Closed/N.O., Option: Brass, Copper or BC6 Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 10 [1 (25A)], Thread: G, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.3 Solenoid, Body Size: 40A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 14 [1 1/2 (40A)], Thread: Rc, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -
Model: -, Orifice: -, Style: -, Option: -, Suffix: -, Port Size: -, Thread: -, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Rectifier: -, Bracket: -
Function: 2 Position Single, Body Style: Body Ported/Individual Pilot EXH, Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1, Thread: NPT, Option: -
Function: 2 Position Single, Body Style: Body Ported/Individual Pilot EXH, Body Option: Body Ported Type, Pilot: Internal Pilot, Voltage: 220VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: Sub-plate Plug-in 1/4, Non Plug-in 1/4, Direct Ported P,A,B Ports 1, Thread: NPTF, Option: -