Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP, 2 Outputs, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP, 2 Outputs, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.01 to 0.03, Piping specifications: Supply side (Rc1/8), detection side (ø4 single-action), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.01 to 0.03, Piping specifications: Supply side (Rc1/8), detection side (ø4 single-action), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.01 to 0.03, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 2 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.02 to 0.15, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: NPN 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (Rc1/8), detection side (ø6 one-touch), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Number of stations: 1 station, Option: With Bracket, Detection distance(mm): 0.05 to 0.30, Piping specifications: Supply side (G1/8), detection side (G1/8), Output specifications: PNP 1 output, Unit specification for pressure values: With unit switching function, Cable: Straight cable
Actuation Type: -, Sealant: Metal Seal, Function: Standard (1W), Voltage: 100VAC 50/60HZ, Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Locking Slotted Style, Protection: Dust Proof, 1: -, Piping Specification: Side Ported, Port Size: 3/8, Thread: NPTF, Composite Symbol: 2 Position Single