END 5 Booster Regulator Series VBA Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure fromdrive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B.
r B " " $6y t " 5 ' % " $60C4,D 4 B u % " " B 17-3-98 Series VVXA21/22 Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil The VX series will be revised shortly.
AP100 17 735 ARM11A/B Series Pressure Switch Block 56 ARM11AW Z A 0.4 0.2 0.6 0.5 20 MPa 24 q w 0.3 0.1 1. Accessory 2.
For safe operation of SMC Thermo-dryer, thoroughly read and follow the safety instructions, as well as regulations stated within ISO 4414*1 & JIS B 8370*2. *1) ISO 4414: Pneumatic fluid power General rules and safety requirements for systems and their components *2) JIS B 8370: Pneumatic fluid power General rules relating to systems This manual is intended to explain the installation and
This item is U n i t N u m b e r M O D E < 0 applicable only when multiple units are used. 2. Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
H Non-leak (105atm cc/sec) Brake oil Water (Up to 60C) B P A H Stainless Steel Note 1) The leakage amount(105atm cc/sec)of "V" option is valued when differential pressure is 0.1MPa.
Analog Output Flow/Analog output Output A B C Voltage output 1 V 1.1 V 5 V Current output 4 mA 4.4 mA 20 mA C Model Rated flow [L/min] Minimum Maximum LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 B A Outside the range 0 Min.
0.2 0.1 0.2 C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed.
(2.5)] VFRA4311-04 3 8 VFRA4411-03 3 position exhaust center 1.2 1 8 PA, B: 51 (2.8) A, BEA, EB: 57.6 (3.2) [A, BEA, EB: 45 (2.5)] 1 2 VFRA4411-04 3 8 65 (3.6) [PA, B: 30.6 (1.7)] VFRA4511-03 3 position pressure center 1.2 1 8 VFRA4511-04 1 2 67 (3.7) [PA, B: 30.6 (1.7)] ( ): in case of normal position.
10A 15A 20A 25A 32A 1 8 1 4 3 8 3 8 1 2 3 4 220 VAC 50/60 Hz Valve size 1 7 5 6 24 VDC 12 VDC B: Slotted locking type B (tool required) 7 240 VAC 50/60 Hz 15 (11) 2 Semi-standard For other rated voltages, please consult with SMC. 20 (14) 3 25 (16) 4 1 1 1 4 32 (22) 5 1 B 1 4 Flange 32F Nil: Non-locking push type 40A 1 1 2 Valve size 2 to 9 40 (28) 6 1 B 1 2 Flange 40F 2 50A 50 (33) 7 50F
How to Order VXA32 VXA31 4 Bracket Nil B None With bracket Stainless steel body model is supplied with bracket.
(mm) Symbol 1 2 3 Note 1) 4 Symbol Nil: Non-locking push type N.C. 1 MPa N.C. 0.5 MPa N.O. 1 MPa C.O. 1 MPa Note) 4 Note 2) A: Non-locking push type A (projecting) 1 6A 8A 10A 1 8 1 4 3 8 5 6 Note 2) 7 Valve size 1 to 4 7 Note 2) 11 15 11 10A 3 8 B: Slotted locking type B (tool required) Note) Note 1) Electrical entry: D or DZ only Note 2) Semi-standard Note 3) For other rated voltages, please
For safety operation of SMC Refrigerated Air Dryer, read thoroughly and follow stated safety instructions, as well as regulation stated within ISO 4414*1 & JIS B 8370*2. *1) ISO 4414: Pneumatic fluid power General rules and safety requirements for systems and their components *2) JIS B 8370: Pneumatic fluid power General rules relating to systems This manual explains about installation
EX245-DY1 . 70 3 No.EX-OMU0020CN 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 : ) JIS
IDFA Series 6-1 Specifications 6 1 IDX-OM-W016 Air dryer6 References 6-3 Dimensions DRAFT AIR OUTLET IDFA3E B Q A E D AIR INLET VENTILATION WITH LAMP SWITCH AIR OUTLET THERMOMETER EVAPORATION G F C DRAFT AIR INLET DRAIN TUBE (O.D.10 LENGTH:0.8m) VENTILATION (820) J TERMINAL BLOCK N L K M H GROMMET POWER SUPPLY ENTRY(17) P Measuremm Model Thread size A B C D E F G H J K L M N P Q IDFA3E Rc3
. (+/10%), 50/60Hz Current consumption Max.5A(100V) Max.9A(100V) Max.4A(240V) Max.10A(100V) Max.4A(240V) Max.8A (200V) Max.2.5A(240V) Inrush current 50A or less Over current protection 10A 14A Do not modify or reconstruct the unit.
B Grommet 100 VAC With surge voltage suppressor 12 One-touch fitting C 110 VAC G H J K 3/8 D 200 VAC 4 10A C37 N.C. 1/2 E 230 VAC 15 15A 3/8 Stainless steel B N.O. F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C.