SMC Corporation of America
Elite Part Number Search
Search Results "VM131F-03-08"

LQ 2 U 03 Tubing size Tubing O.D. 1/8", 3 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 3/4", 19 1", 25 Body class Applicable fitting Symbol 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 19 25 Type of fitting Applicable fitting LQ2 LQ1 Symbol Nil 1 2 Body class Symbol 2 3 4 5 6 Body class 2 3 4 5 6 Applicable fitting 3 LQ2 LQ2 4 LQ1 Type of part Symbol U B N Type of

Symbol Stations 02 08 2 stations 8 stations 2 stations 8 stations 1 3 2 D side U side Stations G: Flat ribbon cable (PC wiring, with power supply terminal) Symbol Stations 02 08 2 stations 8 stations SS3J3-V60PD2-06D 1 set (Manifold part no.)

Note) 1/2 standard Metric size 23 04 06 08 10 12 Inch size Made to Order Refer to page 608 for details. 3.2 01 03 05 07 09 11 13 1/8" With One-touch fittings 4 5/32" Caution 6 3/16" 8 1/4" Be sure to read before handling.

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

Supplied regenerative resistors or regenerative option is used with the servo amplifier of 11k to 22kW. 01: FR-BU2-(H) FR-RC-(H) FR-CV-(H) 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50(Cooling fan is required) 08: MR-RB31 09: MR-RB51(Cooling fan is required) 80: MR-RB1H-4 81: MR-RB3M-4(Cooling fan is required) 82: MR-RB3G-4(Cooling fan is required) 83: MR-RB5G-4(Cooling fan

KA00612M Relief valve FH441 20 to 24 (P85) (P85) (G145) Element KA00713 KA00104 KA01296M FH340 03 to 04 Differential pressure indicator (P22A) (P30) (G80) Case KA00720 KA00107 KA02476 FH34 06 to 08 (P32) (P44) (G105) KA00631M KA00102 KA00104 KA01759 FH44 to 64 03 to 04 (P20) (P30) (G65) w O-ring KA00720 Phosphoric FH44 to 64 06 to 08 FKM-70 FKM-90 KA00107 KA02477 Drain plug (P32) ester KA00722

Recommended flow rate Note) (l/min (ANR)) Internal capacity (cm3) 1.7 Mass (g) ZA Model IN side, OUT side 2 3.2 4 4 6 6 8 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" ZFC050-02 ZFC050-23 ZFC050-04 ZFC100-04 ZFC100-06 ZFC200-06 ZFC200-08 ZFC051-01 ZFC051-03 ZFC101-03 ZFC101-07 ZFC201-07 ZFC201-09 2 7 10 10 20 30 50 7 10 10 20 30 50 4.9 ZX IN/OUT straight piping 1.7 4.3 ZR Metric size Easy installation

Note) Available for the rubber seal type only. 23 Manifold Specification Sheet Series VQC2000: Base-Mounted Type/Plug-in Unit How to order manifolds VV5QC 2 1 08 FD1 B C8 F P T Kit / / 1 2 3 8 VV5QC 2 1 08 SDQ B C8 S Kit Fill out for I/O serial kit only.

AS2052F-A AS1002F-A AS2002F-A 500 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 01, 23, 03, 04, 06, 07 100 08, 09 06, 07 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 400 200 06, 07 03, 04 300 50 200 100 100 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations AS3002F-A AS4002F-A 1500

Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23

Note) When ordering ejector without valve, select Nil for mounting. 04 KJH C2 Port size 04 06 03 07 !

A Note 1) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

A Note 1) 4 6 4 6 8 4 6 8 10 6 8 10 12 10 12 AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 28 7 7 18.4 23.2 8 10.4 22.2 25 25.5 28.3 9.6 M5 x 0.8 12.2 29 8 8 19.4 24.2 12.8 32.4 17 17 18.4 25.3 10.4 27.4 32.4 31.4 36.4 14.2 12

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

A (2) AS121FP-M5-04 AS121FP-M5-06 AS221FP-01-04 AS221FP-01-06 AS221FP-01-08 AS221FP-02-04 AS221FP-02-06 AS221FP-02-08 AS221FP-02-10 AS321FP-03-06 AS321FP-03-08 AS321FP-03-10 AS321FP-03-12 AS421FP-04-10 AS421FP-04-12 4 8 10.4 22.2 17 27 7 7 12.2 28.8 26 M5 x 0.8 9.6 25.2 22.4 6 12.8 23.2 18.5 8 8 28 (12.2) (28.8) (26) 4 10.4 24.3 17 17 17 31.4 13.4 35.5 30.5 6 R 1/8 12 14.2 32.4 27.4 12.8

SX5000-38-16 A SX7000-39-16 A SX7000-38-16 A Dimensions Applicable fittings size d 4 Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" Thread type Nil Rc G F KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 N NPT NPTF T Bolt and gasket part no.

Step Request data Response data Operation details 1 01 03 0600 0004 01 03 08 Acquires the alarm history. 2 Alarm history confirmation Confirms the acquired alarm history. (9) Alarm history clearance example E.g) The Alarm History saved in the Card Motor controller (controller ID1) is cleared.

1.5 Cross section 0.23mm2 VS7 < >: AC 86 78.5 3 4 5 M plug connector (M): VQZ3 5 (R)lMl 0 1 02 03 60.5 Cover diameter 1.5 Cross section 0.23mm2 143.5<145.5> 77 (Lead wire length) 62<67> 65<66> 168 300 Indicator light < >: AC 1.12-45 5 Port Solenoid Valve VQZ1000/2000/3000 Manifold Base Mounted Plug Lead Unit Connector Kit How to Order Manifold VV5QZ 1 5 08 C6 C N Series Options Manifold

02 03 Indicator light 300 89.5 (Lead wire length) Cross section 0.23 mm2 Cover diameter 1.5 Pg.7 55 <60> 92.5 Max. 10 Applicable cable O.D. 3.5 to 7 Indicator light < >: AC 78.5 86 M plug connector (M): VQZ35(R)-M02 03 (Lead wire length) Cross section 0.23 mm2 Cover diameter 1.5 62 <67> 300 95 Indicator light 83.5 < >: AC 4-14-32 33 3 Port Solenoid Valve Metal/Rubber Seal, Base Mounted,

SY SYJ VK Blank plug KQP-23-X19 KQP-04-X19 KQP-06-X19 KQP-08-X19 KQP-10-X19 VZ L Dimensions VT (mm) A One-touch fitting d Part No.