SMC Corporation of America
Elite Part Number Search
Search Results "VEX1133-01-FG"

G33-4-01 G33-10-01 G43-2-01 G43-4-01 G43-10-01 G43-10-01 G43-4-01 G43-10-01 Accuracy + 3% (full span) Courtesy of Steven Engineering, Inc. !

Instruction to perform the Return to Origin operation 4 01 05 001A FF00 01 05 001A FF00 sent. 5 01 02 004B 0001 01 02 01 Acquires the INP signal information.

The terminal abbreviation FG means Frame Ground ie chassis earth.

-23ST 13.5 12 1/4" 3.2 8.4 12.7 AS221F-N01-01ST AS221F-01-04ST 1/8" 8.4 4 20.4 27.5 9.3 5/32" 9.3 20.4 27.5 12.7 14.3 AS221F-N01-03ST AS221F-01-06ST 13.5 12 R 1/8 14.2 7 35.6 1.5 31.6 6 11.6 3/16" 11.4 23.1 30.2 14.3 16.5 AS221F-N01-05ST AS221F-01-08ST NPT 1/8 12.7 14.2 7 35.6 1.5 31.6 25.3 32.4 18.5 8 15.2 AS221F-N01-07ST AS221F-01-10ST 1/4" 13.2 23.9 31 18.5 33.1 40.2 15 21 10 18.5 AS221F-N01

Air Flow/Effective Area Model AS12l1FM AS13l1FM AS22l1FM-01 AS23l1FM-01 AS22l1FM-02 AS23l1FM-02 6, 8 Tube O.D.

With One-touch fitting Port size For low speed control M5 U10/32 01 02 M5 x 0.8 10-32 UNF 1/8 1/4 Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT N Needle Valve/Flow Characteristics AS1201FM, AS1211FM AS1301FM, AS1311FM AS2201FM-01, AS2211FM-01 AS2301FM-01, AS2311FM-01 AS2201FM-02, AS2211FM-02 AS2301FM-02, AS2311FM-02 0.8 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa

: "01""FF" "EE" "OK" LRC CR, LF (b) Irregular response Code ID Command Result Error details Check Start Sum End Code : "01""FF" "EE" "NG" Refer to "5.5 Error Code" LRC CR, LF 15 DATA (Saved Data) Data will be sent as a value to 5 decimal points.

Target position (01-149) Posn failed D SVON Input The connection with the higher-level devices is disconnected. A Communication error occurred (01-150) RESET Communi Do not interrupt the connection between the PC and teaching box when the electric actuator is being operated by upperlevel devices.

-02 AS3201FE, AS3211FE AS3301FE, AS3311FE AS2201FE-01, AS2211FE-01 AS2301FE-01, AS2311FE-01 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Effective area (mm2) Effective area (mm2) Effective area (mm2) Number of needle rotations Number of needle rotations Number of needle rotations AS4201FE, AS4211FE

The output current exceeded the specification (01-194) current E Power Over off An abnormality is detected by the current sensor that is checked when the controller is reset. A current sensor abnormality has occurred. (01-195) Make sure that the electric actuator conforms to the controller.

1 O-ring NBR 01 to 04 type !2 Bushing PBT 01 to 04 type !3 O-ring NBR M3 type PVC !4 Gasket M5, U10/32 type NBR, Stainless steel Note 1) AS220 type is electroless nickel plated. Note 2) AS220 type is made of steel.

NPT thread Model Model 10-32 UNF M5 3/8 1/8 1/4 1/2 3/8 1/8 1/4 1/2 AKH04 AKH06 AKH08 AKH10 AKH12 AKH03 AKH07 AKH09 AKH11 AKH13 4 6 8 10 12 5/32 1/4 5/16 3/8 1/2 From One-touch fitting to male thread B Bushing type AKB 01 A 01 S With seal (Standard) Body size Port size 01 1/8 01 1/8 Thread type 02 1/4 02 1/4 03 3/8 Nil R 03 3/8 04 1/2 N NPT 04 1/2 Check valve free flow direction Female/Male

N01 R1/8 (M5 ) NPT1/8 (M5 ) C3602() O HNBR 45 g 46 g -62No.PS-OMM0006CN-E (M8(3 )71 ) 01/N01 5 4 M5/C4/C6 M5 5 -63No.PS-OMM0006CN-E W1/WF1 4 ( ISO228-1) -64No.PS-OMM0006CN-E A 01/N01 W1/WF1 -65No.PS-OMM0006CN-E B W1/WF1 -66No.PS-OMM0006CN-E D 01/N01 W1/WF1 -67No.PS-OMM0006CN-E 01/N01 W1/WF1/M5/C4/C6 -68No.PS-OMM0006CN-E + 01/N01 W1/WF1/M5/C4/C6 -69No.PS-OMM0006CN-E

M1 M2 Weight (g) ASV310F-01-06S ASV310F-01-08S ASV310F-02-06S ASV310F-02-08S ASV410F-01-08S ASV410F-01-10S ASV410F-02-08S ASV410F-02-10S ASV410F-03-08S ASV410F-03-10S ASV510F-02-10S ASV510F-02-12S ASV510F-03-10S ASV510F-03-12S ASV510F-04-10S ASV510F-04-12S 16.8 19.3 16.8 19.3 19.3 23.3 19.3 23.3 19.3 23.3 23.3 25.7 23.3 25.7 23.3 25.7 71.9 73.8 71.9 73.8 83.1 85.2 83.1 85.2 83.1 85.2 90.2

-I With bracket Bracket A 01/N01 type W1/WF1 type -66No.PS-OMM0007-I Bracket B W1/WF1 type -67No.PS-OMM0007-I Bracket D 01/N01 type W1/WF1 type -68No.PS-OMM0007-I Panel mount adapter 01/N01 type W1/WF1/M5/C4/C6 type -69No.PS-OMM0007-I Panel mount adapter + Front protective cover 01/N01 type W1/WF1/M5/C4/C6 type -70No.PS-OMM0007-I Panel cut-out dimensions -71No.PS-OMM0007-I 01/N01 type (products

Data : [9] [2] : [0] [0] 01 (Turn on SON.) Stop and LSN.) End Command Data No. Data : [8] [B] : [0] [0] 0 (Test operation mode is canceled.) Test operation mode is canceled. 14 34 14. COMMUNICATION FUNCTION (3) Positioning operation (a) Operation procedure Transmit the command, data No., and data as follows to execute positioning operation.

Ionizer IZG10 08 01 01 Ionizer Gun One-touch fitting Nozzle type Symbol Applicable tube O.D.

Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.