B Z + Stroke DB DX DD 90 B 4-DT A DS DH 4-DR DL DU DO DO DC DE DU DA Rotating Angle Bore size (mm) Part no.

12 45 60 58 77.5 166 16+0.070 0 50 65 80 60 10 92 75 109 17 9 17 12 45 60 71 91 183 16+0.070 0 MB-S06 63 75 100 70 15 110 90 130 20 11 22 14 60 80 87 103 195 20+0.084 0 80 95 100 70 15 130 110 150 20 11 22 14 60 80 110 126.5 242 20+0.084 0 MB-S10 100 114 120 90 15 158 132 184 26 13.5 24 17 75 100 136 148.5 261 25+0.084 0 Double clevis pivot bracket B DX Z + Stroke DB DD B 90 4 x DT B A DS

Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14

B Z + Stroke DB DX DD 90 B 4DT A DS DH 4DR DB DU DO DO DC DE DU DL Rotation (mm) No.

VT/O317-G(-02) VT/O317-GS(-02) VT/O317-H(-02) VT/O317-HS(-02) VT/O317-C(-02) VT/O317-CS(-02) VT/O317-T(-02) VT/O317-TS(-02) VT/O317-TZ(-02) VT/O317-D(-02) VT/O317-DS(-02) VT/O317-DZ(-02) Coil no. PVT317-001GBPVT317-G PVT317-001GB-L06 PVT317-G-06 PVT317-001CBPVT317-C Coil assembly with terminal part no.

B Z + Stroke DB DX DD 90 B 4DT A DS DH 4DR DB DU DO DO DC DE DU DL Rotation (mm) No.

Bore size (mm) Z DA DB DL DU DC DX DE DR DO DT DS DH Z DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 32 40 50 63 80 100 32 40 50 63 80 100 6.6 6.6 9 9 11 11 46 52 65 75 95 114 32 32 43 43 64 64 22 22 30 30 45 45 10 10 11.5 11.5 14 14 44 44 60 60 86 86 14 14 20 20 30 30 62 62 81 81 111 111 15 15 18 18 22 22 7 7 8 8 10 10 33 33 45 45 65 65 154 158 182 182 228 228 10 10 14 14

Z Bore size (mm) Z B DA DB DL DU DC DX DE DR DO DT DS DH DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 +0.084 0 32 40 50 63 80 100 125 32 40 50 63 80 100 125 33 33 45 45 65 65 75 46 52 65 75 95 114 136 32 32 43 43 64 64 78 22 22 30 30 45 45 60 10 10 11.5 11.5 14 14 15 44 44 60 60 86 86 110 14 14 20 20 30 30 32 62 62 81 81 111 111 136 6.6 6.6 9 9 11 11 13.5 15 15 18 18 22 22

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SS5Q2 NO SIZE RATING, VALVE, SS5Q2 MANIFOLD SQ2000, 2N, SS5Q2 NO SIZE RATING, 3.74785 lb

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Rc G NPT NPTF 01 1 station Nil None 00F 00N 00T F With bracket (Not mounted) VT 20 20 stations P port: Rc 1/8 R port: Rc 1/8 VP Type 40: Base mounted (A port bottom ported) How to Order Applicable solenoid valve VK334Applicable blanking plate assembly

Thread type 1(P), 3(R) port Nil Rc 00N NPT 00T NPTF 00F G Dusttight/Low Jetproof Type (IP65) DIN terminal is available with dusttight/low jetproof (IP65) type.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SS5X3-20-05 (5 stations) NPTF 00T Stations3 2 1 Connector assembly for L and M types Refer to page 1-6-8. Common connector assembly for manifold Refer to page 1-6-9. SS5X3-20-05 1 set (Type 20, 5-station manifold base part no.)

Thread type (1(P), 3(R2), 5(R1)) ports) Nil Rc 00N NPT 00T NPTF 00F G Dusttight/Low Jetproof Type (IP65) DIN terminal is available with Dusttight/Low jetproof (IP65) type.

Type 20 (5 Port/Body ported) How to Order Applicable solenoid valve M5 C4 C6 M5 C4 C6 SS5YJ520 05 SYJ520-A, B port M5 x 0.8 SYJ523-Applicable blanking plate assembly SYJ5000-21-1A Applicable individual EXH spacer assembly SYJ5000-17-1A P, R port thread type Number of stations -+ -+ P port 1/8 02 2 stations R R P Nil 00F 00N 00T Rc G NPT NPTF : : 20 20 stations R port 1/8 Type 40 (5 Port/

Type 21R Applicable solenoid valve SYJ512R---M5 SYJ522R---M5 How to Order SS3YJ5--21R-05 -A port M5 x 0.8 X port (External pilot type) P, R port thread type Stations Applicable blanking plate assembly SYJ500-10-1A + + + + M5 x 0.8 02 : 20 2 stations : 20 stations Nil Rc G NPT NPTF X 00F 00N 00T P port 1/8 P R R port 1/8 Note) For more than 9 stations, supply/exhaust air to/from both sides

Applicable blanking plate assembly SYJ7000-21-1A Type 21 (5 Port/Body ported) How to Order SS5YJ721 05 A, B port P, R port thread type Applicable individual EXH spacer assembly SYJ7000-17-1A Stations 02 2 stations + + Nil 00F 00N 00T Rc G NPT NPTF : : P port 1/4 R P R 20 20 stations R port 1/4 Note) For more than stations, supply air to both sides of P port and exhaust air from both sides

Type 21R How to Order SS3YJ7--21R-05 -Applicable solenoid valve SYJ712R--01 SYJ722R--01 A port 1/8 P, R port thread type Applicable blanking plate assembly SYJ700-10-2A -+ -+ -+ -+ Stations X port (External pilot type) 02 : 20 2 stations : 20 stations Nil R X Rc G NPT NPTF P 00F 00N 00T M5 x 0.8 R port 1/4 P port Note) For more than 9 stations, supply/exhaust air to/from both sides of P and

S 20 20 stations A,B port side R1,R2 Port M5T M5 0.8 M5 0.8 R1,R2 Port M5 0.8 N3T One-touch fitting A, B Port M5 0.8,N3T P Port NPTF P Port NPTF A, B Port M5 0.8,N3T How To Order: Flat Ribbon Cable Manifold Type 21P (4 Port/Body Ported Type) Applicable valve: SYJ3 23 LOU --M3 SYJ3 23Y LOU --M3 5 6 5 6 AB Port M3 0.5 SS5YJ3--21P-07 00T Applicable connector ass'y: SY3000-37-28A (For 2

YZ-DIN connector YOS-DIN terminal without connector With light and surge voltage suppressor With surge voltage suppressor Note) Standard lead wire length: 300mm Coil voltage 1 2 3 4 5 6 9 100VAC(50/60Hz) 200VAC(50/60Hz) 110VAC(50/60Hz) 220VAC(50/60Hz) 24VDC 12VDC Others 21 Series VQZ How To Order Manifold Connector Kit How To Order: VQZ100 Body Ported Manifold Preferred Option Program C 00T

Rubber seal 0.15 to 0.7MPa 0.2 to 0.7MPa VQZ100: (Poppet ) How to Order Manifold Operating press. range (1) Vacuum to 0.7MPa VV3QZ22 05C 00T Note 1) In case of the high pressure style, the upper limit of max. operating pressure and external pressure range is 1MPa. Note 2) If VQZ100 is applied in vacuum, vacuum from P port.