SMC Corporation of America
Elite Part Number Search
Search Results "SS5Q13-03FD2-ES"

Note 2) Confirm that it is possible to securely set the auto switch(es) within the range of indicator green light ON range before use. For in-line entry type, please also consider Note 1) shown above. Note 3) The D-P3DWA can be mounted on bore sizes 32 to 63. MGJ JMGP MGP Other than the applicable auto switches listed in How to Order, the following auto switches are mountable.

(For M8: 0.05 Nm, For M12: 0.1 Nm) EX500 AW Connector type ES TP TS M8 connector (For socket) M12 connector (For plug) M12 connector (For socket) Waterproof cap 1-2-28 25 Series SV Series EX500 Decentralized Serial Wiring Dimensions: Series SV1000 for EX500 Decentralized Serial Wiring Cassette base manifold: SS5V1-W16SAWDU D B C3, N1 C4, N3 C6, N7 (S, R, RS) Stations When P, E port outlets

Port size Symbol Port size Rated ow range 03 06 12 10 1 14 1 1/2 20 2 Output specification Symbol OUT FUNC2 Applicable monitor unit model CS NPN Analog voltage output3 External input4 PFG300 series DS NPN Analog current output External input4 PFG310 series ES PNP Analog voltage output3 External input4 PFG300 series FS PNP Analog current output External input4 PFG310 series 2 Analog output

Note 3) In case of 5mm stroke (with 1 pc.) or 10mm stroke (2 pcs.), the switch(es) may not go off or more than one switch may turn on simultaneously. Set them at 1 to 4mm out of the values in the above table. Note 4) ( ): Dimensions for D-A93. Specific Product Precautions Be sure to read before handling. Mounting Caution 1.

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: Rc, Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: F [G (ISO 1179-1 Compliant)], Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)

Rated Flow Range: 06 (60 to 6000 l/min), Thread Type: N (NPT), Port Size: 14 (1 1/2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)